Excellent Outcomes for Transcatheter Aortic Valve Replacement Within 1 Year of Opening a Low-Volume Centre and Consideration of Requirements

被引:8
作者
Chevalier, Florent [1 ]
Poulin, Frederic [1 ]
Lamarche, Yoan [1 ,2 ]
Le, Van Hoai Viet [1 ]
Gallant, Melanie [1 ]
Daoust, Anik [1 ]
Heylbroeck, Christophe [1 ]
Serri, Karim [1 ]
Beaulieu, Yanick [1 ]
Demers, Philippe [1 ,2 ]
El-Hamamsy, Ismail [1 ,2 ]
Jeanmart, Hugues [1 ,2 ]
Page, Pierre [1 ,2 ]
Schampaert, Erick [1 ]
Palisaitis, Donald [1 ]
Genereux, Philippe [1 ]
机构
[1] Hop Sacre Coeur, Montreal, PQ H4J 1C5, Canada
[2] Inst Cardiol Montreal, Montreal, PQ, Canada
关键词
HIGH-RISK PATIENTS; COST-EFFECTIVENESS; HEART-VALVE; EAE/ASE RECOMMENDATIONS; INOPERABLE PATIENTS; CLINICAL-OUTCOMES; IMPLANTATION; STENOSIS; REGURGITATION; PROSTHESIS;
D O I
10.1016/j.cjca.2014.08.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: After the approval of transcatheter aortic valve replacement (TAVR) for high-risk or inoperable patients with severe aortic stenosis (AS), many low- and moderate-volume TAVR programs were initiated. Contemporary outcomes from these newly initiated centres remain unknown. Methods: In March 2013, our institution was authorized by the Quebec Ministry of Health to perform 30 TAVR procedures. After thorough clinical screening and imaging evaluation, suitable patients underwent transfemoral TAVR with the balloon-expandable SAPIEN XT (Edwards Lifesciences, Irvine, CA) transcatheter heart valve (THV). In-hospital and 30-day outcomes were prospectively collected and reported according to Valve Academic Research Consortium 2 guidelines. Results: From April 2013 to January 2014, 30 consecutive high-risk (n = 16 [53.3%]) or inoperable (n = 14 [46.7%]) patients (mean age, 84.6 years; mean Society of Thoracic Surgery score, 7) with symptomatic severe AS underwent transfemoral TAVR. No catastrophic intraprocedural complications such as annulus rupture, valve embolization, aortic dissection, or coronary occlusion occurred, and there were no deaths at 30 days. Disabling stroke occurred in 1 (3.3%) patient 48 hours after THV implantation. Major vascular complications and major bleeding occurred in 1 (3.3%) patient. No moderate or severe paravalvular leak was observed. The median length of stay was 2 (1-3) days, with 8 (26.7%) patients discharged within 24 hours after the procedure. Conclusions: Excellent outcomes can be achieved in newly initiated relatively low-volume centres, which compares favorably to previously published large series. Important considerations include appropriate team training, rigorous patient screening, use of multimodality imaging techniques, a heart team approach, constant integration of lessons learned from larger published experiences, and maintaining a recommended minimum volume of 25 cases per year.
引用
收藏
页码:1576 / 1582
页数:7
相关论文
共 44 条
  • [1] Comparison of Balloon-Expandable vs Self-expandable Valves in Patients Undergoing Transcatheter Aortic Valve Replacement The CHOICE Randomized Clinical Trial
    Abdel-Wahab, Mohamed
    Mehilli, Julinda
    Frerker, Christian
    Neumann, Franz-Josef
    Kurz, Thomas
    Toelg, Ralph
    Zachow, Dirk
    Guerra, Elena
    Massberg, Steffen
    Schaefer, Ulrich
    El-Mawardy, Mohamed
    Richardt, Gert
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 311 (15): : 1503 - 1514
  • [2] Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
    Kaul, Sanjay
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2014, 371 (10) : 967 - 967
  • [3] Transcatheter Aortic Valve Implantation Assessing the Learning Curve
    Alli, Oluseun O.
    Booker, Jeffrey D.
    Lennon, Ryan J.
    Greason, Kevin L.
    Rihal, Charanjit S.
    Holmes, David R., Jr.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (01) : 72 - 79
  • [4] Underexpansion and Ad Hoc Post-Dilation in Selected Patients Undergoing Balloon-Expandable Transcatheter Aortic Valve Replacement
    Barbanti, Marco
    Leipsic, Jonathon
    Binder, Ronald
    Dvir, Danny
    Tan, John
    Freeman, Melanie
    Norgaard, Bjarne
    Hansson, Nicolaj
    Cheung, Anson
    Ye, Jian
    Yang, Tae-Hyun
    Maryniak, Kasia
    Raju, Rekha
    Thompson, Angus
    Blanke, Philipp
    Lauck, Sandra
    Wood, David
    Webb, John
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (10) : 976 - 981
  • [5] Echocardiographic Assessment of Valve Stenosis: EAE/ASE Recommendations for Clinical Practice
    Baumgartner, Helmut
    Hung, Judy
    Bermejo, Javier
    Chambers, John B.
    Evangelista, Arturo
    Griffin, Brian P.
    Iung, Bernard
    Otto, Catherine M.
    Pellikka, Patricia A.
    Quinones, Miguel
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (01) : 1 - 23
  • [6] Transcatheter Aortic Valve Replacement With the SAPIEN 3 A New Balloon-Expandable Transcatheter Heart Valve
    Binder, Ronald K.
    Rodes-Cabau, Josep
    Wood, David A.
    Mok, Michael
    Leipsic, Jonathon
    De Larochelliere, Robert
    Toggweiler, Stefan
    Dumont, Eric
    Freeman, Melanie
    Willson, Alexander B.
    Webb, John G.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (03) : 293 - 300
  • [7] Transcatheter Aortic Valve Replacement With a New Self-Expanding Transcatheter Heart Valve and Motorized Delivery System
    Binder, Ronald K.
    Schaefer, Ulrich
    Kuck, Karl-Heinz
    Wood, David A.
    Moss, Robert
    Leipsic, Jonathon
    Toggweiler, Stefan
    Freeman, Melanie
    Ostry, Avi J.
    Frerker, Christian
    Willson, Alexander B.
    Webb, John G.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (03) : 301 - 307
  • [8] Transcatheter Aortic Valve Implantation: Recommendations for Practice Based on a Multidisciplinary Review Including Cost-Effectiveness and Ethical and Organizational Issues
    Boothroyd, Lucy J.
    Spaziano, Marco
    Guertin, Jason R.
    Lambert, Laurie J.
    Rodes-Cabau, Josep
    Noiseux, Nicolas
    Michel Nguyen
    Dumont, Eric
    Carrier, Michel
    de Varennes, Benoit
    Ibrahim, Reda
    Martucci, Giuseppe
    Xiao, Yongling
    Morin, Jean E.
    Bogaty, Peter
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2013, 29 (06) : 718 - 726
  • [9] Velocity Vector Imaging: Standard Tissue-Tracking Results Acquired in Normals-The VVI-STRAIN Study
    Carasso, Shemy
    Biaggi, Patric
    Rakowski, Harry
    Mutlak, Diab
    Lessick, Jonathan
    Aronson, Doron
    Woo, Anna
    Agmon, Yoram
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (05) : 543 - 552
  • [10] Valve-in-Valve Implantation With a 23-mm Balloon-Expandable Transcatheter Heart Valve for the Treatment of a 19-mm Stentless Bioprosthesis Severe Aortic Regurgitation Using a Strategy of "Extreme" Underfilling
    Chevalier, Florent
    Leipsic, Jonathon
    Genereux, Philippe
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 84 (03) : 503 - 508