Polymeric mercaptosilane-modified platinum electrodes for elimination of interferants in glucose biosensors

被引:90
作者
Jung, SK
Wilson, GS
机构
[1] UNIV KANSAS,DEPT CHEM,LAWRENCE,KS 66045
[2] UNIV KANSAS,CTR NEUROSCI & IMMUNOL RES,LAWRENCE,KS 66045
关键词
D O I
10.1021/ac950424p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An oxidase-based glucose sensor has been developed that uses a mercaptosilane-modified platinum electrode to achieve selectivity of electrochemical interferants. A platinum-iridium (9:1) wire (0.178 mm o.d., sensing area of 1.12 mm(2)) is modified with (3-mercaptopropyl)trimethoxysilane. The modified sensors show excellent operational stability for more than 5 days. Glucose oxidase is immobilized on the modified surface (i) by using 3-maleimidopropionic acid as a linker or (ii) by cross-linking with bovine serum albumin using glutaraldehyde. Sensitivities in the range of 9.97 nA/mM glucose are observed when the enzyme is immobilized by method ii, Lower sensitivities (1.13 x 10(-1) nA/mM glucose) are observed when immobilization method i is employed. In terms of linear response range, the sensor enzyme-immobilized by method i is superior to that immobilized by method ii. The linearity is improved upon coating the enzyme layer with polyurethane, The sensor immobilized by method ii and coated with polyurethane exhibits a linear range to 15 mM glucose and excellent selectivity to glucose (0.47 nA/mM) against interferants such as ascorbic acid, uric acid, and acetaminophen.
引用
收藏
页码:591 / 596
页数:6
相关论文
共 30 条
[1]  
AMINE A, 1989, ANAL LETT, V22, P2403
[2]   FORMATION OF MONOLAYER FILMS BY THE SPONTANEOUS ASSEMBLY OF ORGANIC THIOLS FROM SOLUTION ONTO GOLD [J].
BAIN, CD ;
TROUGHTON, EB ;
TAO, YT ;
EVALL, J ;
WHITESIDES, GM ;
NUZZO, RG .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (01) :321-335
[3]   ELECTROCHEMISTRY AT OMEGA-HYDROXY THIOL COATED ELECTRODES .3. VOLTAGE INDEPENDENCE OF THE ELECTRON-TUNNELING BARRIER AND MEASUREMENTS OF REDOX KINETICS AT LARGE OVERPOTENTIALS [J].
BECKA, AM ;
MILLER, CJ .
JOURNAL OF PHYSICAL CHEMISTRY, 1992, 96 (06) :2657-2668
[4]   IMMOBILIZATION OF BETA-GALACTOSIDASE AND OTHER ENZYMES ONTO PARA-AMINO-CARBANILATED CELLULOSE DERIVATIVES [J].
BEDDOWS, CG ;
MIRAUER, RA ;
GUTHRIE, JT .
BIOTECHNOLOGY AND BIOENGINEERING, 1980, 22 (02) :311-321
[5]  
BEVERETT WR, 1995, ANAL CHEM, V67, P292
[6]   DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING [J].
BINDRA, DS ;
ZHANG, YN ;
WILSON, GS ;
STERNBERG, R ;
THEVENOT, DR ;
MOATTI, D ;
REACH, G .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1692-1696
[7]   SUPERLATTICE STRUCTURE AT THE SURFACE OF A MONOLAYER OF OCTADECANETHIOL SELF-ASSEMBLED ON AU(111) [J].
CAMILLONE, N ;
CHIDSEY, CED ;
LIU, GY ;
SCOLES, G .
JOURNAL OF CHEMICAL PHYSICS, 1993, 98 (04) :3503-3511
[8]   SELECTIVITY AND SENSITIVITY OF SELF-ASSEMBLED THIOCTIC ACID ELECTRODES [J].
CHENG, Q ;
BRAJTERTOTH, A .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1998-2000
[9]   MODIFICATION OF ELECTRODE SURFACES WITH OXIDIZED PHENOLS TO CONFER SELECTIVITY TO AMPEROMETRIC BIOSENSORS FOR GLUCOSE DETERMINATION [J].
CHRISTIE, IM ;
VADGAMA, P ;
LLOYD, S .
ANALYTICA CHIMICA ACTA, 1993, 274 (02) :191-199
[10]   SOL-GEL ENCAPSULATION METHODS FOR BIOSENSORS [J].
DAVE, BC ;
DUNN, B ;
VALENTINE, JS ;
ZINK, JI .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :A1120-A1127