Studying pharmaceutical tablet coating process with real-time terahertz in-line sensing

被引:0
作者
Lin, Hungyen [1 ]
May, Robert K. [2 ]
Evans, Michael J. [2 ]
Zhong, Shuncong [3 ]
Warr, Ian [4 ]
Gladden, Lynn F. [1 ]
Shen, Yaochun [5 ]
Zeitler, J. Axel [1 ]
机构
[1] Univ Cambridge, Dept Chem Engn & Biotechnol, Cambridge CB2 3RA, England
[2] TeraView Ltd, St Johns Innovat Park, Cambridge CB4 0WS, England
[3] Fuzhou Univ, Sch Mech Engn & Automat, Fuzhou 350108, Peoples R China
[4] Oystar Manesty, Prescot L34 9JS, England
[5] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, Merseyside, England
来源
2013 38TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ) | 2013年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Terahertz in-line sensing was successfully demonstrated previously for measuring the coating thickness of individual pharmaceutical tablets during a production scale film coating process. This paper investigates how this technology can be used to evaluate the impact of changes in the process conditions on the inter-tablet coating thickness distribution. The process changes that were investigated in this study were the removal of the mixing baffles from the coating pan, blockage of one of the spray guns and the addition of uncoated tablet cores to a bed of partially coated tablets. Using the terahertz sensor the coating thickness of more than 20 individual tablets was sampled per minute in situ throughout the coating process. By analysing the resulting variation in coating thickness distribution it was possible to resolve the effect of all these process changes on the coating thickness homogeneity within the batch.
引用
收藏
页数:2
相关论文
共 50 条
  • [11] In-line, real-time chip monitor
    Stuart, WB
    Auel, JB
    1996 PULPING CONFERENCE, BOOKS 1 AND 2, 1996, : 687 - 692
  • [12] Real-time monitoring of the tablet-coating process by near-infrared spectroscopy - Effects of coating polymer concentrations on pharmaceutical properties of tablets
    Hattori, Yusuke
    Sugata, Misuzu
    Kamata, Hitoshi
    Nagata, Makoto
    Nagato, Takuya
    Hasegawa, Kouji
    Otsuka, Makoto
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2018, 46 : 111 - 121
  • [13] Real-Time In-Line Coherent Distributed Sensing over a Legacy Submarine Cable
    Mazur, Mikael
    Fontaine, Nicolas K.
    Ryf, Roland
    Pilgrim, Philip
    Chodkiewicz, Tracy
    Sosa, Gonzalo
    Carter, Stephen D.
    Jasso, Sergio Velazquez
    Naik, Jeewan
    Padmaraju, Kishore
    Mistry, Ajay
    Winter, David
    Dallachiesa, Lauren
    Chen, Haoshuo
    Neilson, David T.
    2024 OPTICAL FIBER COMMUNICATIONS CONFERENCE AND EXHIBITION, OFC, 2024,
  • [14] A Study on In-Line Tablet Coating—the Influence of Compaction and Coating on Tablet Dimensional Changes
    C. Cahyadi
    B. X. Tan
    L. W. Chan
    P. W. S. Heng
    AAPS PharmSciTech, 2012, 13 : 785 - 792
  • [15] PAT Implementation on a Mobile Continuous Pharmaceutical Manufacturing System: Real-Time Process Monitoring with In-Line FTIR and Raman Spectroscopy
    Miyai, Yuma
    Formosa, Anna
    Armstrong, Cameron
    Marquardt, Brian
    Rogers, Luke
    Roper, Thomas
    ORGANIC PROCESS RESEARCH & DEVELOPMENT, 2021, 25 (12) : 2707 - 2717
  • [16] AI-based analysis of in-line process endoscope images for real-time particle size measurement in a continuous pharmaceutical milling process
    Madarasz, Lajos
    Meszaros, Lilla Alexandra
    Kote, Akos
    Farkas, Attila
    Nagy, Zsombor Kristof
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2023, 641
  • [17] In-Line Monitoring of Coating Thickness of Pharmaceutical Tablets during Production Scale Film Coating by Terahertz Imaging
    May, Robert K.
    Evans, Michael J.
    Zhong, Shuncong
    Warr, Ian
    Gladden, Lynn F.
    Shen, Yaochun
    Zeitler, J. Axel
    35TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ 2010), 2010,
  • [18] In-line laboratory and real-time quality management
    Valleur, M.
    HYDROCARBON PROCESSING, 2009, 88 (03): : 59 - 65
  • [19] Real-time, in-line measurement of kinematic viscosity
    Canter, Neil
    Tribology and Lubrication Technology, 2004, 60 (10 PART 1): : 13 - 14
  • [20] In-Line Monitoring of a Pharmaceutical Pan Coating Process by Optical Coherence Tomography
    Markl, Daniel
    Hannesschlaeger, Guenther
    Sacher, Stephan
    Leitner, Michael
    Buchsbaum, Andreas
    Pescod, Russel
    Baele, Thomas
    Khinast, Johannes G.
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2015, 104 (08) : 2531 - 2540