500kV Transmission Line Lightning Transformation Evaluation Based on Improved Analytic Hierarchy Process

被引:0
|
作者
Duan, R. C. [1 ]
Wang, F. H. [1 ]
Liu, Y. D. [1 ]
Huang, R. H. [2 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Elect Engn, Shanghai 200030, Peoples R China
[2] Shenzhen Power Grid Co Ltd, Dept Grid Technol, Shenzhen, Guangdong, Peoples R China
关键词
500kV lightning protection; EGM; IAHP; Transmission line; Shielding failure rate;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Reasonable protection measures can improve the lightning performance of 500-kV transmission lines and reduce trip-out rates. An assessment method based on IAHP is proposed to formulate lightning protection measures in accordance with the evaluation process of screen-selection-optimization. Based on several commonly existed lightning transformations, perform technical and economic analysis first to obtain the primary choice. Then, theoretical lightning protection measure is selected by comprehensively considering constrained factors according to the IAHP weights. Thereby, examine whether the transformation works by calculating the shielding failure rate through the establishment of EGM model, thus the optimal method is confirmed finally. The application of the method is illustrated by using a typical 500 kV transmission line under complex terrain, and the expected evaluation results have shown that the proposed protection performance can meet the transformation requirements well and guide engineering practice effectively.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Urban Sports Level Evaluation based on Improved Fuzzy Analytic Hierarchy Process
    Yuan, Li
    2016 INTERNATIONAL CONFERENCE ON SMART GRID AND ELECTRICAL AUTOMATION (ICSGEA 2016), 2016, : 167 - 170
  • [32] Computational Analysis of 500kV Transmission Line Distortion Field near Trees
    Song, Fugen
    Lin, Han
    Lan, Sheng
    INTERNATIONAL JOURNAL OF GRID AND DISTRIBUTED COMPUTING, 2016, 9 (10): : 263 - 272
  • [33] Design of the DC ±500kV Full Scale Transmission Test Line in Gochang
    Shin, Koo-yong
    Lee, Dong-il
    Lim, Jae-seop
    Ju, Mun-no
    Yang, Kwang-ho
    T& D ASIA: 2009 TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: ASIA AND PACIFIC, 2009, : 311 - 314
  • [34] The Evaluation of Network Video QoE Based on an Improved Fuzzy Analytic Hierarchy Process
    Yan, Min
    Gao, Suixiang
    Yang, Wenguo
    PROCEEDINGS OF THE 2016 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY, ENVIRONMENT AND CHEMICAL ENGINEERING (AEECE 2016), 2016, 89 : 322 - 328
  • [35] Comprehensive evaluation based on improved analytic hierarchy process for AC/DC microgrid
    Liu Z.
    Wei T.
    Li M.
    Cao Z.
    Li W.
    Hui H.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2016, 36 (03): : 60 - 66and78
  • [36] Comprehensive evaluation of power failure based on improved extension analytic hierarchy process
    Zhou J.
    Luo T.
    Li Z.
    Chen G.
    Yu H.
    Zhu J.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (03): : 31 - 38
  • [37] Using the ORACLE Database Management for 500kV Transmission Line Fault Features
    Liang, Yongchao
    Zhang, Xijia
    Zhu, Tianyi
    INDUSTRIAL INSTRUMENTATION AND CONTROL SYSTEMS II, PTS 1-3, 2013, 336-338 : 2083 - +
  • [38] Electromagnetic field evaluation of a 500kV high voltage overhead line
    Mpanga, S. (shadreck.mpanga@gmail.com), 1600, Universitas Ahmad Dahlan, Jalan Kapas 9, Semaki, Umbul Harjo,, Yogiakarta, 55165, Indonesia (11):
  • [39] Effect of Line Splitting by New Substation on 500kV Transmission Line Compensated at One End
    Kusuma, Aristo Adi
    Pramana, Putu Agus Aditya
    Harsono, Brian Bramantyo S. D. A.
    Munir, Buyung Sofiarto
    2019 1ST INTERNATIONAL CONFERENCE ON CYBERNETICS AND INTELLIGENT SYSTEM (ICORIS), 2019, : 62 - 67
  • [40] The Lightning Shielding Effect to ±1100 kV UHVDC Line Provided by a Parallel 500kV AC Line in a Joint Right-of-Way
    Sun, Zezhong
    Lan, Lei
    Zhu, Changcheng
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,