Technical Note: Homogeneity of Gafchromic® EBT2 film

被引:108
作者
Hartmann, Bernadette [1 ,2 ]
Martisikova, Maria [1 ]
Jaekel, Oliver [1 ,3 ]
机构
[1] German Canc Res Ctr, Dept Med Phys Radiat Oncol, D-69120 Heidelberg, Germany
[2] Univ Halle Wittenberg, Inst Phys, D-06120 Halle, Germany
[3] Univ Klinikum Heidelberg, Heidelberger Lonenstrahl Therapiezentrum HIT, D-69120 Heidelberg, Germany
关键词
dosimeters; dosimetry; radiation therapy; FLAT-BED SCANNER; RADIOCHROMIC FILM; DOSIMETRY;
D O I
10.1118/1.3368601
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Methods: A scan protocol established for EBT film and published previously was used. The uniformity of the film coloration was investigated for unirradiated and irradiated EBT2 film sheets. The dose response of EBT2 film was measured and the influence of film inhomogeneities on dose determination was evaluated. Results: Inhomogeneities in pixel values of up to +/- 3.7% within one film were detected. The relative inhomogeneities were found to be approximately independent of the dose. Nonuniformities of the film response lead to uncertainties in dose determination of +/- 8.7% at 1 Gy. When using net optical densities for dose calibration, uncertainties in dose determination amount to more than +/- 6%. Conclusions: EBT2 films from the lot investigated in this study show response inhomogeneities, which lead to uncertainties in dose determination exceeding the commonly accepted tolerance levels. It is important to test further EBT2 lots regarding homogeneity before using the film in clinical routine.
引用
收藏
页码:1753 / 1756
页数:4
相关论文
共 10 条
[1]   Absorption spectra variations of EBT radiochromic film from radiation exposure [J].
Butson, MJ ;
Cheung, T ;
Yu, PKN .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (13) :N135-N140
[2]   Post-irradiation colouration of Gafchromic EBT radiochromic film [J].
Cheung, T ;
Butson, MJ ;
Yu, PKN .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (20) :N281-N285
[3]   Precise radiochromic film dosimetry using a flat-bed document scanner [J].
Devic, S ;
Seuntjens, J ;
Sham, E ;
Podgorsak, EB ;
Schmidtlein, CR ;
Kirov, AS ;
Soares, CG .
MEDICAL PHYSICS, 2005, 32 (07) :2245-2253
[4]   Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry [J].
Ferreira, B. C. ;
Lopes, M. C. ;
Capela, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (04) :1073-1085
[5]   Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance [J].
Fuss, Martina ;
Sturtewagen, Eva ;
De Wagter, Carlos ;
Georg, Dietmar .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (14) :4211-4225
[6]  
*INT SPEC PROD, 2006, GAFCHR EBT
[7]  
International Speciality Products, GAFCHR EBT2
[8]   Analysis of uncertainties in Gafchromic® EBT film dosimetry of photon beams [J].
Martisikova, Maria ;
Ackermann, Benjamin ;
Jaekel, Oliver .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (24) :7013-7027
[9]   Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry [J].
Paelinck, L. ;
De Neve, W. ;
DeWagter, C. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (01) :231-242
[10]   Accurate dosimetry with GafChromic™ EBT film of a 6 MV photon beam in water:: What level is achievable? [J].
van Batturn, L. J. ;
Hoffmans, D. ;
Piersma, H. ;
Heukelom, S. .
MEDICAL PHYSICS, 2008, 35 (02) :704-716