Data-driven gating in PET: Influence of respiratory signal noise on motion resolution

被引:13
|
作者
Buether, Florian [1 ]
Ernst, Iris [2 ]
Frohwein, Lynn Johann [3 ]
Pouw, Joost [1 ,4 ]
Schaefers, Klaus Peter [3 ]
Stegger, Lars [1 ]
机构
[1] Univ Hosp Munster, Dept Nucl Med, Albert Schweitzer Campus 1, D-48149 Munster, Germany
[2] German CyberKnife Ctr, Senator Schwartz Ring 8, D-59494 Soest, Germany
[3] Univ Munster, European Inst Mol Imaging, Waldeyerstr 15, D-48149 Munster, Germany
[4] Univ Twente, Magnet Detect & Imaging Grp, Drienerlolaan 5, NL-7522 NB Enschede, Netherlands
关键词
data-driven gating; PET; CT; MRI; respiratory motion; POSITRON-EMISSION-TOMOGRAPHY; SOFTWARE; SCANNER; PERFORMANCE; PHANTOM; THORAX; IMPACT; 4D-CT; CT; 3D;
D O I
10.1002/mp.12987
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeData-driven gating (DDG) approaches for positron emission tomography (PET) are interesting alternatives to conventional hardware-based gating methods. In DDG, the measured PET data themselves are utilized to calculate a respiratory signal, that is, subsequently used for gating purposes. The success of gating is then highly dependent on the statistical quality of the PET data. In this study, we investigate how this quality determines signal noise and thus motion resolution in clinical PET scans using a center-of-mass-based (COM) DDG approach, specifically with regard to motion management of target structures in future radiotherapy planning applications. MethodsPET list mode datasets acquired in one bed position of 19 different radiotherapy patients undergoing pretreatment [F-18]FDG PET/CT or [F-18]FDG PET/MRI were included into this retrospective study. All scans were performed over a region with organs (myocardium, kidneys) or tumor lesions of high tracer uptake and under free breathing. Aside from the original list mode data, datasets with progressively decreasing PET statistics were generated. From these, COM DDG signals were derived for subsequent amplitude-based gating of the original list mode file. The apparent respiratory shift d from end-expiration to end-inspiration was determined from the gated images and expressed as a function of signal-to-noise ratio SNR of the determined gating signals. This relation was tested against additional 25 [F-18]FDG PET/MRI list mode datasets where high-precision MR navigator-like respiratory signals were available as reference signal for respiratory gating of PET data, and data from a dedicated thorax phantom scan. ResultsAll original 19 high-quality list mode datasets demonstrated the same behavior in terms of motion resolution when reducing the amount of list mode events for DDG signal generation. Ratios and directions of respiratory shifts between end-respiratory gates and the respective nongated image were constant over all statistic levels. Motion resolution d/d(max) could be modeled as d/dmax=1-e-1.52(SNR-1)0.52, with d(max) as the actual respiratory shift. Determining d(max) from d and SNR in the 25 test datasets and the phantom scan demonstrated no significant differences to the MR navigator-derived shift values and the predefined shift, respectively. ConclusionsThe SNR can serve as a general metric to assess the success of COM-based DDG, even in different scanners and patients. The derived formula for motion resolution can be used to estimate the actual motion extent reasonably well in cases of limited PET raw data statistics. This may be of interest for individualized radiotherapy treatment planning procedures of target structures subjected to respiratory motion.
引用
收藏
页码:3205 / 3213
页数:9
相关论文
共 50 条
  • [1] Sign determination methods for the respiratory signal in data-driven PET gating
    Bertolli, Ottavia
    Arridge, Simon
    Wollenweber, Scott D.
    Stearns, Charles W.
    Hutton, Brian F.
    Thielemans, Kris
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (08) : 3204 - 3220
  • [2] Sign Determination Methods for the Respiratory Signal in Data-Driven PET Gating
    Bertolli, Ottavia
    Arridge, Simon
    Stearns, Charles W.
    Wollenweber, Scott D.
    Hutton, Brian F.
    Thielemans, Kris
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [3] Clinical Evaluation of a Data-Driven Respiratory Gating Algorithm for Whole-Body PET with Continuous Bed Motion
    Buether, Florian
    Jones, Judson
    Seifert, Robert
    Stegger, Lars
    Schleyer, Paul
    Schaefers, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61 (10) : 1520 - 1527
  • [4] Evaluation of data-driven respiratory gating waveforms for clinical PET imaging
    Walker, Matthew D.
    Morgan, Andrew J.
    Bradley, Kevin M.
    McGowan, Daniel R.
    EJNMMI RESEARCH, 2019, 9 (1)
  • [5] Impact of Data-driven Respiratory Gating in Clinical PET
    Buether, Florian
    Vehren, Thomas
    Schaefers, Klaus P.
    Schaefers, Michael
    RADIOLOGY, 2016, 281 (01) : 229 - 238
  • [6] Retrospective data-driven respiratory gating for PET/CT
    Schleyer, Paul J.
    O'Doherty, Michael J.
    Barrington, Sally F.
    Marsden, Paul K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07) : 1935 - 1950
  • [7] Data-driven gating (DDG)-based motion match for improved CTAC registration
    Cook, Ella L.
    Su, Kuan-Hao
    Higgins, Geoff S.
    Johnsen, Robert
    Bouhnik, Jean-Paul
    McGowan, Daniel R.
    EJNMMI PHYSICS, 2024, 11 (01):
  • [8] External radioactive markers for PET data-driven respiratory gating in positron emission tomography
    Buether, Florian
    Ernst, Iris
    Hamill, James
    Eich, Hans T.
    Schober, Otmar
    Schaefers, Michael
    Schaefers, Klaus P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (04) : 602 - 614
  • [9] Data-driven gated CT: An automated respiratory gating method to enable data-driven gated PET/CT
    Pan, Tinsu
    Thomas, M. Allan
    Luo, Dershan
    MEDICAL PHYSICS, 2022, 49 (06) : 3597 - 3611
  • [10] Comparison of Different Methods for Data-driven Respiratory Gating of PET Data
    Thielemans, Kris
    Schleyer, Paul
    Marsden, Paul K.
    Manjeshwar, Ravindra M.
    Wollenweber, Scott D.
    Ganin, Alexander
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,