Intrapartum fetal heart rate patterns in the prediction of neonatal acidemia

被引:89
作者
Williams, KP [1 ]
Galerneau, F [1 ]
机构
[1] Yale Univ, Sch Med, Dept Obstet & Gynecol, New Haven, CT 06510 USA
关键词
electronic fetal heart rate monitoring; intrapartum fetal heart rate monitoring; baseline variability;
D O I
10.1067/mob.2003.183
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: This study was undertaken to correlate changes in the intrapartum electronic fetal heart rate patterns with the development of significant neonatal acidemia. STUDY DESIGN: We identified 488 fetuses at a gestational age of >37 weeks' gestation who had continuous electronic fetal monitoring during labor for the last 2 hours and umbilical artery cord gas analysis performed at delivery. One investigator blinded to the cord gas outcome reviewed all 488 tracings using the National Institute of Child Health and-Human Development guidelines for fetal heart rate monitoring. All fetal heart rate tracings with bradycardia were removed from further analysis. The patients were placed in six groups, depending on the absence or presence of normal variability (amplitude >5 beats) during the last hour of monitoring combined with the absence of decelerations or the presence of variable or late decelerations. The relationship between changes in variability and the outcome variables of pH and base deficit in the six groups was assessed with analysis of variance and chi(2) test. Significance was set at the P < .05 level. RESULTS: Patients with normal variability and accelerations, even in the presence of late decelerations or variable decelerations, maintained an umbilical artery pH 7.0 or greater in more than 97% of cases. In the presence of minimal/absent variability (amplitude < 5) for at least an hour, the incidence of significant acidemia (pH < 7.0) ranged from (12%-31%). CONCLUSION: The most significant intrapartum fetal heart rate parameter to predict the development of significant acidemia is the presence of minimal/absent variability for at least 1 hour as a solitary abnormal finding or in conj. unction with late decelerations in the absence of accelerations. Urgent delivery should be considered in these cases after appropriate ancillary testing.
引用
收藏
页码:820 / 823
页数:4
相关论文
共 20 条
  • [1] BANTA HD, DHEWPHS793245
  • [2] THE SCALP STIMULATION TEST - A CLINICAL ALTERNATIVE TO FETAL SCALP BLOOD-SAMPLING
    CLARK, SL
    GIMOVSKY, ML
    MILLER, FC
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1984, 148 (03) : 274 - 277
  • [3] FETAL HEART-RATE RESPONSE TO SCALP BLOOD-SAMPLING
    CLARK, SL
    GIMOVSKY, ML
    MILLER, FC
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1982, 144 (06) : 706 - 708
  • [4] Electronic fetal heart rate monitoring: Early neonatal outcomes associated with normal rate, fetal stress, and fetal distress
    Dellinger, EH
    Boehm, FH
    Crane, MM
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2000, 182 (01) : 214 - 220
  • [5] Dildy GA, 1996, AM J OBSTET GYNECOL, V175, P682
  • [6] EDINGTON PT, 1975, BRIT MED J, V3, P341
  • [7] THE DEVELOPMENT OF FETAL ACIDOSIS IN THE PRESENCE OF AN ABNORMAL FETAL HEART-RATE TRACING .1. THE AVERAGE FOR GESTATIONAL-AGE FETUS
    FLEISCHER, A
    SCHULMAN, H
    JAGANI, N
    MITCHELL, J
    RANDOLPH, G
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1982, 144 (01) : 55 - 60
  • [8] DIAGNOSIS OF BIRTH ASPHYXIA ON THE BASIS OF FETAL PH, APGAR SCORE, AND NEWBORN CEREBRAL-DYSFUNCTION
    GILSTRAP, LC
    LEVENO, KJ
    BURRIS, J
    WILLIAMS, ML
    LITTLE, BB
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1989, 161 (03) : 825 - 830
  • [9] GOLDABER KG, 1991, OBSTET GYNECOL, V78, P1103
  • [10] JOHNSTONE FD, 1978, LANCET, V1, P1298