Variable flip angle echo planar time-resolved imaging (vFA-EPTI) for fast high-resolution gradient echo myelin water imaging

被引:15
|
作者
Dong, Zijing [1 ,2 ]
Wang, Fuyixue [1 ,3 ]
Chan, Kwok-Shing [4 ]
Reese, Timothy G. [1 ]
Bilgic, Berkin [1 ,3 ]
Marques, Jose P. [4 ]
Setsompop, Kawin [1 ,3 ]
机构
[1] Massachusetts Gen Hosp, Athinoula A Martins Ctr Biomed Imaging, Charlestown, MA 02129 USA
[2] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[3] MIT, Harvard MIT Hlth Sci & Technol, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[4] Radhoud Univ, Donders Inst Brain Cognit & Behav, Nijmegen, Netherlands
关键词
Myelin water imaging; Fast imaging; High resolution; Multi-compartment; Myeloarchitecture; Cortical layers; PROSPECTIVE MOTION CORRECTION; MULTIPLE-SCLEROSIS; HUMAN BRAIN; RECONSTRUCTION; VISUALIZATION; RELAXATION; FIELD;
D O I
10.1016/j.neuroimage.2021.117897
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Myelin water imaging techniques based on multi-compartment relaxometry have been developed as an important tool to measure myelin concentration in vivo, but are limited by the long scan time of multi-contrast multi-echo acquisition. In this work, a fast imaging technique, termed variable flip angle Echo Planar Time-Resolved Imaging (vFA-EPTI), is developed to acquire multi-echo and multi-flip-angle gradient-echo data with significantly reduced acquisition time, providing rich information for multi-compartment analysis of gradient-echo myelin water imaging (GRE-MWI). The proposed vFA-EPTI method achieved 26 folds acceleration with good accuracy by utilizing an efficient continuous readout, optimized spatiotemporal encoding across echoes and flip angles, as well as a joint subspace reconstruction. An approach to estimate off-resonance field changes between different flip-angle acquisitions was also developed to ensure high-quality joint reconstruction across flip angles. The accuracy of myelin water fraction (MWF) estimate under high acceleration was first validated by a retrospective undersampling experiment using a lengthy fully-sampled data as reference. Prospective experiments were then performed where whole-brain MWF and multi-compartment quantitative maps were obtained in 5 min at 1.5 mm isotropic resolution and 24 min at 1 mm isotropic resolution at 3T. Additionally, ultra-high resolution data at 600 mu m isotropic resolution were acquired at 7T, which show detailed structures within the cortex such as the line of Gennari, demonstrating the ability of the proposed method for submillimeter GRE-MWI that can be used to study cortical myeloarchitecture in vivo
引用
收藏
页数:12
相关论文
共 43 条
  • [41] Rapid 3-D mapping of hyperpolarized 3He spin-lattice relaxation times using variable flip angle gradient echo imaging with application to alveolar oxygen partial pressure measurement in rat lungs
    Ouriadov, Alexei V.
    Lam, Wilfred W.
    Santyr, Giles E.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2009, 22 (05) : 309 - 318
  • [42] Evaluation of breast lesions based on modified BI-RADS using high-resolution readout-segmented diffusion-weighted echo-planar imaging and T2/T1-weighted image
    Ota, Rie
    Kataoka, Masako
    Iima, Mami
    Honda, Maya
    Kishimoto, Ayami Ohno
    Miyake, Kanae Kawai
    Yamada, Yosuke
    Takeuchi, Yasuhide
    Toi, Masakazu
    Nakamoto, Yuji
    MAGNETIC RESONANCE IMAGING, 2023, 98 : 132 - 139
  • [43] Accurate T1 mapping of short T2 tissues using a three-dimensional ultrashort echo time cones actual flip angle imaging-variable repetition time (3D UTE-Cones AFI-VTR) method
    Ma, Ya-Jun
    Lu, Xing
    Carl, Michael
    Zhu, Yanchun
    Szeverenyi, Nikolaus M.
    Bydder, Graeme M.
    Chang, Eric Y.
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (02) : 598 - 608