Variable flip angle echo planar time-resolved imaging (vFA-EPTI) for fast high-resolution gradient echo myelin water imaging

被引:15
|
作者
Dong, Zijing [1 ,2 ]
Wang, Fuyixue [1 ,3 ]
Chan, Kwok-Shing [4 ]
Reese, Timothy G. [1 ]
Bilgic, Berkin [1 ,3 ]
Marques, Jose P. [4 ]
Setsompop, Kawin [1 ,3 ]
机构
[1] Massachusetts Gen Hosp, Athinoula A Martins Ctr Biomed Imaging, Charlestown, MA 02129 USA
[2] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[3] MIT, Harvard MIT Hlth Sci & Technol, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[4] Radhoud Univ, Donders Inst Brain Cognit & Behav, Nijmegen, Netherlands
关键词
Myelin water imaging; Fast imaging; High resolution; Multi-compartment; Myeloarchitecture; Cortical layers; PROSPECTIVE MOTION CORRECTION; MULTIPLE-SCLEROSIS; HUMAN BRAIN; RECONSTRUCTION; VISUALIZATION; RELAXATION; FIELD;
D O I
10.1016/j.neuroimage.2021.117897
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Myelin water imaging techniques based on multi-compartment relaxometry have been developed as an important tool to measure myelin concentration in vivo, but are limited by the long scan time of multi-contrast multi-echo acquisition. In this work, a fast imaging technique, termed variable flip angle Echo Planar Time-Resolved Imaging (vFA-EPTI), is developed to acquire multi-echo and multi-flip-angle gradient-echo data with significantly reduced acquisition time, providing rich information for multi-compartment analysis of gradient-echo myelin water imaging (GRE-MWI). The proposed vFA-EPTI method achieved 26 folds acceleration with good accuracy by utilizing an efficient continuous readout, optimized spatiotemporal encoding across echoes and flip angles, as well as a joint subspace reconstruction. An approach to estimate off-resonance field changes between different flip-angle acquisitions was also developed to ensure high-quality joint reconstruction across flip angles. The accuracy of myelin water fraction (MWF) estimate under high acceleration was first validated by a retrospective undersampling experiment using a lengthy fully-sampled data as reference. Prospective experiments were then performed where whole-brain MWF and multi-compartment quantitative maps were obtained in 5 min at 1.5 mm isotropic resolution and 24 min at 1 mm isotropic resolution at 3T. Additionally, ultra-high resolution data at 600 mu m isotropic resolution were acquired at 7T, which show detailed structures within the cortex such as the line of Gennari, demonstrating the ability of the proposed method for submillimeter GRE-MWI that can be used to study cortical myeloarchitecture in vivo
引用
收藏
页数:12
相关论文
共 43 条
  • [31] High-resolution diffusion imaging with DIFRAD-FSE (diffusion-weighted radial acquisition of data with fast spin-echo) MRI
    Trouard, TP
    Theilmann, RJ
    Altbach, MI
    Gmitro, AF
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (01) : 11 - 18
  • [32] Fast imaging of lenticulostriate arteries by high-resolution black-blood T1-weighted imaging with variable flip angles and acceleration by compressed sensitivity encoding
    Zhang, Yukun
    Cao, Jiajun
    Qiao, Chen
    Gao, Bingbing
    Du, Wei
    Lin, Liangjie
    Liu, Na
    Song, Qingwei
    Miao, Yanwei
    MAGNETIC RESONANCE IMAGING, 2024, 110 : 51 - 56
  • [33] Evaluation of Malignant Breast Lesions Using High-resolution Readout-segmented Diffusion-weighted Echo-planar Imaging: Comparison with Pathology
    Kishimoto, Ayami Ohno
    Kataoka, Masako
    Iima, Mami
    Honda, Maya
    Miyake, Kanae Kawai
    Ohashi, Akane
    Ota, Rie
    Kataoka, Tatsuki
    Sakurai, Takaki
    Toi, Masakazu
    Togashi, Kaori
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2021, 20 (02) : 204 - 215
  • [34] High-resolution distortion-free diffusion imaging using hybrid spin-warp and echo-planar PSF-encoding approach
    In, Myung-Ho
    Posnansky, Oleg
    Speck, Oliver
    NEUROIMAGE, 2017, 148 : 20 - 30
  • [35] High-fidelity, high-spatial-resolution diffusion magnetic resonance imaging of ex vivo whole human brain at ultra-high gradient strength with structured low-rank echo-planar imaging ghost correction
    Ramos-Llorden, Gabriel
    Lobos, Rodrigo A.
    Kim, Tae Hyung
    Tian, Qiyuan
    Witzel, Thomas
    Lee, Hong-Hsi
    Scholz, Alina
    Keil, Boris
    Yendiki, Anastasia
    Bilgic, Berkin
    Haldar, Justin P.
    Huang, Susie Y.
    NMR IN BIOMEDICINE, 2023, 36 (02)
  • [36] Fast 3D ultrashort echo-time spiral projection imaging using golden-angle: A flexible protocol for in vivo mouse imaging at high magnetic field
    Castets, Charles R.
    Lefrancois, William
    Wecker, Didier
    Ribot, Emeline J.
    Trotier, Aurelien J.
    Thiaudiere, Eric
    Franconi, Jean-Michel
    Miraux, Sylvain
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (05) : 1831 - 1840
  • [37] Optimizing signal-to-noise ratio of high-resolution parallel single-shot diffusion-weighted echo-planar imaging at ultrahigh field strengths
    Reischauer, Carolin
    Vorburger, Robert S.
    Wilm, Bertram J.
    Jaermann, Thomas
    Boesiger, Peter
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (03) : 679 - 690
  • [38] Accelerated Acquisition of High-resolution Diffusion-weighted Imaging of the Brain with a Multi-shot Echo-planar Sequence: Deep-learning-based Denoising
    Kawamura, Motohide
    Tamada, Daiki
    Funayama, Satoshi
    Kromrey, Marie-Luise
    Ichikawa, Shintaro
    Onishi, Hiroshi
    Motosugi, Utaroh
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2021, 20 (01) : 99 - 105
  • [39] Depiction of Achilles Tendon Microstructure In Vivo Using High-Resolution 3-Dimensional Ultrashort Echo-Time Magnetic Resonance Imaging at 7 T
    Han, Misung
    Larson, Peder E. Z.
    Liu, Jing
    Krug, Roland
    INVESTIGATIVE RADIOLOGY, 2014, 49 (05) : 339 - 345
  • [40] Rapid 3-D mapping of hyperpolarized 3He spin-lattice relaxation times using variable flip angle gradient echo imaging with application to alveolar oxygen partial pressure measurement in rat lungs
    Alexei V. Ouriadov
    Wilfred W. Lam
    Giles E. Santyr
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2009, 22 : 309 - 318