Variable flip angle echo planar time-resolved imaging (vFA-EPTI) for fast high-resolution gradient echo myelin water imaging

被引:15
|
作者
Dong, Zijing [1 ,2 ]
Wang, Fuyixue [1 ,3 ]
Chan, Kwok-Shing [4 ]
Reese, Timothy G. [1 ]
Bilgic, Berkin [1 ,3 ]
Marques, Jose P. [4 ]
Setsompop, Kawin [1 ,3 ]
机构
[1] Massachusetts Gen Hosp, Athinoula A Martins Ctr Biomed Imaging, Charlestown, MA 02129 USA
[2] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[3] MIT, Harvard MIT Hlth Sci & Technol, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[4] Radhoud Univ, Donders Inst Brain Cognit & Behav, Nijmegen, Netherlands
关键词
Myelin water imaging; Fast imaging; High resolution; Multi-compartment; Myeloarchitecture; Cortical layers; PROSPECTIVE MOTION CORRECTION; MULTIPLE-SCLEROSIS; HUMAN BRAIN; RECONSTRUCTION; VISUALIZATION; RELAXATION; FIELD;
D O I
10.1016/j.neuroimage.2021.117897
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Myelin water imaging techniques based on multi-compartment relaxometry have been developed as an important tool to measure myelin concentration in vivo, but are limited by the long scan time of multi-contrast multi-echo acquisition. In this work, a fast imaging technique, termed variable flip angle Echo Planar Time-Resolved Imaging (vFA-EPTI), is developed to acquire multi-echo and multi-flip-angle gradient-echo data with significantly reduced acquisition time, providing rich information for multi-compartment analysis of gradient-echo myelin water imaging (GRE-MWI). The proposed vFA-EPTI method achieved 26 folds acceleration with good accuracy by utilizing an efficient continuous readout, optimized spatiotemporal encoding across echoes and flip angles, as well as a joint subspace reconstruction. An approach to estimate off-resonance field changes between different flip-angle acquisitions was also developed to ensure high-quality joint reconstruction across flip angles. The accuracy of myelin water fraction (MWF) estimate under high acceleration was first validated by a retrospective undersampling experiment using a lengthy fully-sampled data as reference. Prospective experiments were then performed where whole-brain MWF and multi-compartment quantitative maps were obtained in 5 min at 1.5 mm isotropic resolution and 24 min at 1 mm isotropic resolution at 3T. Additionally, ultra-high resolution data at 600 mu m isotropic resolution were acquired at 7T, which show detailed structures within the cortex such as the line of Gennari, demonstrating the ability of the proposed method for submillimeter GRE-MWI that can be used to study cortical myeloarchitecture in vivo
引用
收藏
页数:12
相关论文
共 43 条
  • [1] Echo planar time-resolved imaging (EPTI)
    Wang, Fuyixue
    Dong, Zijing
    Reese, Timothy G.
    Bilgic, Berkin
    Manhard, Mary Katherine
    Chen, Jingyuan
    Polimeni, Jonathan R.
    Wald, Lawrence L.
    Setsompop, Kawin
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (06) : 3599 - 3615
  • [2] Fast and high-resolution myelin water imaging: Accelerating multi-echo GRASE with CAIPIRINHA
    Piredda, Gian Franco
    Hilbert, Tom
    Jorge Canales-Rodriguez, Erick
    Pizzolato, Marco
    von Deuster, Constantin
    Meuli, Reto
    Pfeuffer, Josef
    Daducci, Alessandro
    Thiran, Jean-Philippe
    Kober, Tobias
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (01) : 223 - 236
  • [3] 3D Echo Planar Time-resolved Imaging (3D-EPTI) for ultrafast multi-parametric quantitative MRI
    Wang, Fuyixue
    Dong, Zijing
    Reese, Timothy G.
    Rosen, Bruce
    Wald, Lawrence L.
    Setsompop, Kawin
    NEUROIMAGE, 2022, 250
  • [4] Propeller echo-planar time-resolved imaging with dynamic encoding
    Fair, Merlin J.
    Wang, Fuyixue
    Dong, Zijing
    Reese, Timothy G.
    Setsompop, Kawin
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (06) : 2124 - 2137
  • [5] Echo planar time-resolved imaging with subspace reconstruction and optimized spatiotemporal encoding
    Dong, Zijing
    Wang, Fuyixue
    Reese, Timothy G.
    Bilgic, Berkin
    Setsompop, Kawin
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (05) : 2442 - 2455
  • [6] High-Resolution Echo-Planar Spectroscopic Imaging of the Human Calf
    Weis, Jan
    Bruvold, Morten
    Ortiz-Nieto, Francisco
    Ahlstrom, Hakan
    PLOS ONE, 2014, 9 (01):
  • [7] A Modified EPI Sequence for High-Resolution Imaging at Ultra-Short Echo Time
    Hetzer, Stefan
    Mildner, Toralf
    Moeller, Harald E.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (01) : 165 - 175
  • [8] VARIABLE FLIP ANGLE IMAGING AND FAT SUPPRESSION IN COMBINED GRADIENT AND SPIN-ECHO (GREASE) TECHNIQUES
    VINITSKI, S
    MITCHELL, DG
    SZUMOWSKI, J
    BURK, DL
    RIFKIN, MD
    MAGNETIC RESONANCE IMAGING, 1990, 8 (02) : 131 - 139
  • [9] Single-shot echo planar time-resolved imaging for multi-echo functional MRI and distortion-free diffusion imaging
    Dong, Zijing
    Wald, Lawrence L.
    Polimeni, Jonathan R.
    Wang, Fuyixue
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (03) : 993 - 1013
  • [10] High-resolution echo-planar spectroscopic imaging at ultra-high field
    Coello, Eduardo
    Noeske, Ralph
    Burns, Brian L.
    Gordon, Jeremy W.
    Jakary, Angela
    Menze, Bjoern
    Haase, Axel
    Larson, Peder E. Z.
    Li, Yan
    Schulte, Rolf F.
    NMR IN BIOMEDICINE, 2018, 31 (11)