Clinical applications of high-speed blood flow measurements with Diffuse Correlation Spectroscopy

被引:1
|
作者
Parthasarathy, Ashwin B. [1 ,2 ]
Baker, Wesley B. [1 ]
Gannon, Kimberly [3 ]
Mullen, Michael T. [3 ]
Detre, John A. [3 ]
Yodh, Arjun G. [1 ]
机构
[1] Univ Penn, Dept Phys & Astron, Philadelphia, PA 19104 USA
[2] Univ S Florida, Dept Elect Engn, Tampa, FL 33620 USA
[3] Hosp Univ Penn, Div Stroke & Neurocrit Care, Philadelphia, PA 19104 USA
基金
美国国家卫生研究院;
关键词
Cerebral Blood Flow; Clinical Measurements; Diffuse Correlation Spectroscopy; AUTOREGULATION;
D O I
10.1117/12.2253488
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Diffuse Correlation Spectroscopy (DCS) is an increasingly popular non-invasive optical technique to clinically measure deep tissue blood flow, albeit at slow measurement rates of 0.5-1 Hz. We recently reported the development of a new 'fast' DCS instrument that continuously measures blood flow at 50-100 Hz (simultaneously from 8 channels), using conventional DCS sources/detectors, and optimized software computations. A particularly interesting result was our ability to optically record pulsatile micro-vascular blood flow waveforms, and therein readily identify high frequency features such as the dicrotic notch. Here, we showcase the utility and potential of high-speed measurements of blood flow (and arterial blood pressure) in a few clinical applications. First, we employ the fast-DCS instrumentation to measure cerebral autoregulation (CVAR) dynamics. Cerebral autoregulation refers to the mechanism by which cerebral blood flow (CBF) is maintained during fluctuations in blood pressure; CVAR is impaired in the injured brain. We derive an index of autoregulation by measuring the rates of decrease (and recovery) of blood flow and blood pressure following a sudden, induced change in systemic blood pressure (e.g., bilateral thigh cuff deflation). Our pilot experiments in healthy volunteers show that DCS measured rates of micro-vascular regulation are comparable to conventional large vessel regulatory metrics (e.g., measured with transcranial Doppler ultrasound). Second, we utilized pulsatile blood flow oscillations in cerebral arteries to estimate the critical closing pressure (CrCP), i.e., the arterial blood pressure at which CBF approaches zero. Pilot experiments in healthy subjects show good agreement between CrCP measured with DCS and transcranial Doppler ultrasound.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Portable, high speed blood flow measurements enabled by long wavelength, interferometric diffuse correlation spectroscopy (LW-iDCS)
    Robinson, Mitchell B. B.
    Renna, Marco
    Ozana, Nisan
    Martin, Alyssa N. N.
    Otic, Nikola
    Carp, Stefan A. A.
    Franceschini, Maria Angela
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [2] Portable, high speed blood flow measurements enabled by long wavelength, interferometric diffuse correlation spectroscopy (LW-iDCS)
    Mitchell B. Robinson
    Marco Renna
    Nisan Ozana
    Alyssa N. Martin
    Nikola Otic
    Stefan A. Carp
    Maria Angela Franceschini
    Scientific Reports, 13
  • [3] Hematocrit significantly confounds diffuse correlation spectroscopy measurements of blood flow
    Sathialingam, Eashani
    Williams, Evelyn Kendall
    Lee, Seung Yup
    McCracken, Courtney E.
    Lam, Wilbur A.
    Buckley, Erin M.
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (08) : 4786 - 4799
  • [4] Diffuse correlation spectroscopy measurements of blood flow using 1064 nm light
    Carp, Stefan A.
    Tamborini, Davide
    Mazumder, Dibbyan
    Wu, Kuan-Cheng
    Robinson, Mitchell R.
    Stephens, Kimberly A.
    Shatrovoy, Oleg
    Lue, Niyom
    Ozana, Nisan
    Blackwell, Megan H.
    Franceschini, Maria A.
    JOURNAL OF BIOMEDICAL OPTICS, 2020, 25 (09)
  • [5] Influences of tissue absorption and scattering on diffuse correlation spectroscopy blood flow measurements
    Irwin, Daniel
    Dong, Lixin
    Shang, Yu
    Cheng, Ran
    Kudrimoti, Mahesh
    Stevens, Scott D.
    Yu, Guoqiang
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (07): : 1969 - 1985
  • [6] Clinical applications of near-infrared diffuse correlation spectroscopy and tomography for tissue blood flow monitoring and imaging
    Shang, Yu
    Li, Ting
    Yu, Guoqiang
    PHYSIOLOGICAL MEASUREMENT, 2017, 38 (04) : R1 - R26
  • [7] Influence of oversimplifying the head anatomy on cerebral blood flow measurements with diffuse correlation spectroscopy
    Zhao, Hongting
    Buckley, Erin M.
    NEUROPHOTONICS, 2023, 10 (01)
  • [8] A Study on Blood Flow Measurement by Diffuse Correlation Spectroscopy
    Liang Jia-ming
    Wang Jing
    Mei Jian-sheng
    Zhang Zhen-xi
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (10) : 2749 - 2752
  • [9] Methods and applications of high-speed MR spectroscopy
    Maudsley, AA
    ULTRAFAST MAGNETIC RESONANCE IMAGING IN MEDICINE, 1999, 1192 : 249 - 254
  • [10] Effects of muscle fiber motion on diffuse correlation spectroscopy blood flow measurements during exercise
    Shang, Yu
    Symons, T. B.
    Durduran, Turgut
    Yodh, A. G.
    Yu, Guoqiang
    BIOMEDICAL OPTICS EXPRESS, 2010, 1 (02): : 500 - 511