Finite element modelling of timber infilled steel tubular short columns under axial compression

被引:19
|
作者
Navaratnam, Satheeskumar [1 ]
Thamboo, Julian [2 ]
Poologanathan, Keerthan [3 ]
Roy, Krishanu [4 ]
Gatheeshgar, Perampalam [3 ]
机构
[1] RMIT Univ, Sch Engn, Melbourne, Vic 3001, Australia
[2] South Eastern Univ Sri Lanka, Dept Civil Engn, Oluvil 32360, Sri Lanka
[3] Northumbria Univ, Fac Engn & Environm, Newcastle Upon Tyne, Tyne & Wear, England
[4] Univ Auckland, Dept Civil & Environm Engn, Auckland, New Zealand
关键词
Timber infilled steel tubular columns; Compressive strength; Finite Element modelling; Ductility; Confinement; Local bucking; COLD-FORMED STEEL; STRUCTURAL RESPONSE; NUMERICAL-ANALYSIS; STUB COLUMNS; BEHAVIOR; PERFORMANCE; BEAMS; CONNECTIONS; SYSTEMS; DESIGN;
D O I
10.1016/j.istruc.2020.12.087
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Timber infilled steel tubular (TIST) columns can be a promising alternative to the concrete infilled steel tubular (CIST) columns, particularly for the lightly loaded prefabricated structures, as timber is lighter and more sustainable material than the conventional concrete. However, limited research studies were dedicated to investigate the structural behaviour of TIST columns. Therefore, in this study an attempt has been made to investigate the parameters that influence the compressive behaviour and to develop appropriate design guidelines through finite element (FE) analyses of TIST columns. A three-dimensional FE modelling technique of TIST has been developed and validated with available experimental results. The developed model considered the steel tube induced confinement on the strength and orthotropic characteristics of timber as well as contact interaction between steel and timber. The validated modelling technique has been extended to parametrically (120 FE models) study the compressive behaviour of TIST columns varying parameters such as strength properties of steel and timber, thicknesses of steel tube, and cross-sectional shapes. The analyses reveal that the TIST columns can be used on par with CIST columns. The calculated strength and ductility indices reveal that the maximum strength and ductility enhancement up to 60% and 65% can be achieved with TIST. Further, the parametric analyses results have been used to verify suitable design formulations for TIST column, subsequently the design formations that are similar to CIST columns can consciously be extended to design the TIST columns.
引用
收藏
页码:910 / 924
页数:15
相关论文
共 50 条
  • [31] Axial compression performance of square UHPC-filled stainless-steel tubular columns
    Zhao, Zhuang
    Wei, Yang
    Wang, Gaofei
    Zhang, Yirui
    Lin, Yu
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 408
  • [32] Behavior of Rectangular-Sectional Steel Tubular Columns Filled with High-Strength Steel Fiber Reinforced Concrete Under Axial Compression
    Liu, Shiming
    Ding, Xinxin
    Li, Xiaoke
    Liu, Yongjian
    Zhao, Shunbo
    MATERIALS, 2019, 12 (17)
  • [33] Code based assessment of load capacity of steel tubular columns infilled with recycled aggregate concrete under compression
    Kadhim, Ihsan Taha
    Guneyisi, Esra Mete
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 168 : 715 - 731
  • [34] Experimental investigation of rubberised concrete-filled double skin square tubular columns under axial compression
    Elchalakani, Mohamed
    Hassanein, M. F.
    Karrech, Ali
    Yang, Bo
    ENGINEERING STRUCTURES, 2018, 171 : 730 - 746
  • [35] Structural performance of short concrete-filled steel tube columns with external and internal stiffening under axial compression
    Alrebeh, Salih K.
    Ekmekyapar, Talha
    STRUCTURES, 2019, 20 : 702 - 716
  • [36] Analytical Model of Circular CFRP Confined Concrete-Filled Steel Tubular Columns under Axial Compression
    Choi, Kang-Kyu
    Xiao, Yan
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2010, 14 (01) : 125 - 133
  • [37] Primary analysis of Concrete-Filled Steel Tubular Slender Columns with Elliptical Section under Axial Compression
    Jiang, Zhiguo
    Zhao, Xiong
    Ren, Qingxin
    Wu, Jinguo
    Tan, Chuang
    CONSTRUCTION AND URBAN PLANNING, PTS 1-4, 2013, 671-674 : 736 - +
  • [38] Mechanical Performance of Stiffened Concrete Filled Double Skin Steel Tubular Stub Columns under Axial Compression
    Hasan, Hussein Ghanim
    Ekmekyapar, Talha
    KSCE JOURNAL OF CIVIL ENGINEERING, 2019, 23 (05) : 2281 - 2292
  • [39] An experimental study on FRC infilled steel tubular columns under eccentric loading
    Gopal, S. Ramana
    KSCE JOURNAL OF CIVIL ENGINEERING, 2017, 21 (03) : 923 - 927
  • [40] A hybrid model for predicting the axial compression capacity of square concrete-filled steel tubular columns
    Sy Hung Mai
    Ben Seghier, Mohamed El Amine
    Phuong Lam Nguyen
    Jafari-Asl, Jafar
    Duc-Kien Thai
    ENGINEERING WITH COMPUTERS, 2022, 38 (02) : 1205 - 1222