The effect slot positions and dimensions have on the size of the ablation zone, reflected power and highest temperature reached by microwave antennas in a hepatic tissue phantom is analyzed with COMSOL Multiphysics. Two antenna configurations are analyzed, coaxial double slot and single slot with choke while taking into account antenna heating.
引用
收藏
页码:41 / 44
页数:4
相关论文
共 14 条
[1]   Antenna design for microwave hepatic ablation using an axisymmetric electromagnetic model [J].
Bertram, John M. ;
Yang, Deshan ;
Converse, Mark C. ;
Webster, John G. ;
Mahvi, David M. .
BIOMEDICAL ENGINEERING ONLINE, 2006, 5 (1)
[2]   Radiofrequency and Microwave Ablation of the Liver, Lung, Kidney, and Bone: What Are the Differences? [J].
Brace, Christopher L. .
CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2009, 38 (03) :135-143
[3]  
Health Policy Advisory Committee on Technology, 2015, TECHN BRIEF UPD MICR
[4]   Microwave ablation: Results with a 2.45-GHz applicator in ex vivo bovine and in vivo porcine liver [J].
Hines-Peralta, AU ;
Pirani, N ;
Clegg, P ;
Cronin, N ;
Ryan, TP ;
Liu, ZJ ;
Goldberg, SN .
RADIOLOGY, 2006, 239 (01) :94-102
[5]   Comparison of Four Microwave Ablation Devices: An Experimental Study in ex Vivo Bovine Liver [J].
Hoffmann, Ruediger ;
Rempp, Hansjoerg ;
Erhard, Ludwig ;
Blumenstock, Gunnar ;
Pereira, Philippe L. ;
Claussen, Claus D. ;
Clasen, Stephan .
RADIOLOGY, 2013, 268 (01) :89-97
[6]  
Lloyd D. M., INT MICROWAVE TUMOUR, V13, P579
[7]   Microwave Tumor Ablation: Mechanism of Action, Clinical Results, and Devices [J].
Lubner, Meghan G. ;
Brace, Christopher L. ;
Hinshaw, J. Louis ;
Lee, Fred T., Jr. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 21 (08) :S192-S203
[8]   Microwave hepatic ablation: Initial experience of safety and efficacy [J].
Martin, Robert C. G. ;
Scoggins, Charles R. ;
McMasters, Kelly M. .
JOURNAL OF SURGICAL ONCOLOGY, 2007, 96 (06) :481-486
[9]   Radiofrequency ablation of the liver: Current status [J].
McGahan, JP ;
Dodd, GD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (01) :3-16
[10]   A Study of the Effects of Geometry on the Efficiency of Single Slot Microwave Ablation Antennas used in Hepatic Tumor Hyperthermia [J].
Neagu, V. .
INTERNATIONAL CONFERENCE ON ADVANCEMENTS OF MEDICINE AND HEALTH CARE THROUGH TECHNOLOGY, MEDITECH 2016, 2017, 59 :131-136