Changes in Optical Path Length Reveal Significant Potential Errors of Muscle Oxygenation Evaluation during Exercise in Humans

被引:5
作者
Endo, Tasuki [1 ]
Kime, Ryotaro [1 ]
Fuse, Sayuri [1 ]
Murase, Norio [1 ]
Kurosawa, Yuko [1 ]
Hamaoka, Takafumi [1 ]
机构
[1] Tokyo Med Univ, Dept Sports Med Hlth Promot, Tokyo, Japan
关键词
NEAR-INFRARED TIME-RESOLVED SPECTROSCOPY; INCREMENTAL EXERCISE; MUSCLE OXYGENATION; REDUCED SCATTERING COEFFICIENT; OPTICAL PATH LENGTH; NEAR-INFRARED SPECTROSCOPY; TIME-RESOLVED SPECTROSCOPY; TISSUE OXYGENATION; O-2; EXTRACTION; ADIPOSE-TISSUE; BLOOD-FLOW; DEOXYGENATION; PATHLENGTH; QUADRICEPS; HYPEREMIA;
D O I
10.1249/MSS.0000000000002530
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose Near-infrared spectroscopy (NIRS), performed with a commonly available noninvasive tissue oxygenation monitoring device, is based on the modified Beer-Lambert law (MBLL). Although NIRS based on MBLL (NIRSMBLL) assumes that the optical path length (PL) is constant, the effects of changes in PL during exercise on muscle oxygenation calculated by MBLL are still incompletely understood. Thus, the purposes of this study were to examine the changes in optical properties during ramp incremental exercise and to compare muscle oxygen dynamics measured by time-resolved NIRS with those calculated based on MBLL. Methods Twenty-two healthy young men performed ramp incremental cycling exercise until exhaustion. Optical properties (reduced scattering coefficient and PL) and absolute oxygenated, deoxygenated, and total hemoglobin and myoglobin concentrations (oxy[Hb + Mb], deoxy[Hb + Mb], and total[Hb + Mb], respectively) at the vastus lateralis were continuously monitored by a three-wavelength (763, 801, and 836) time-resolved NIRS device. The values of oxy-, deoxy-, and total[Hb + Mb] were then recalculated by assuming constant PL. Results PL at all wavelengths statistically significantly shortened during exercise. In particular, PL at 763 nm was greatly shortened, and the average changes during exercise were a 9.8% +/- 3.1% reduction. In addition, significant differences in the kinetics of oxy-, deoxy-, and total[Hb + Mb] between directly measuring PL and assuming constant PL were found. The average changes in measured PL and assuming constant PL-deoxy[Hb + Mb] were increases of 28.8 +/- 16.0 mu M and increases of 16.4 +/- 9.3 mu M, respectively. Conclusion Assuming constant PL in NIRSMBLL significantly underestimated actual muscle oxy/deoxygenation as compared with measurements obtained by real-time PL determination. The percent degree of the underestimated oxy/deoxygenation was greater than the percent degree of the changes in PL.
引用
收藏
页码:853 / 859
页数:7
相关论文
共 35 条
  • [1] Understanding near infrared spectroscopy and its application to skeletal muscle research
    Barstow, Thomas J.
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2019, 126 (05) : 1360 - 1376
  • [2] CHANGES IN SKELETAL-MUSCLE OXYGENATION DURING INCREMENTAL EXERCISE MEASURED WITH NEAR-INFRARED SPECTROSCOPY
    BELARDINELLI, R
    BARSTOW, TJ
    PORSZASZ, J
    WASSERMAN, K
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1995, 70 (06): : 487 - 492
  • [3] Slowed oxygen uptake kinetics in hypoxia correlate with the transient peak and reduced spatial distribution of absolute skeletal muscle deoxygenation
    Bowen, T. Scott
    Rossiter, Harry B.
    Benson, Alan P.
    Amano, Tatsuro
    Kondo, Narihiko
    Kowalchuk, John M.
    Koga, Shunsaku
    [J]. EXPERIMENTAL PHYSIOLOGY, 2013, 98 (11) : 1585 - 1596
  • [4] RECOVERY FROM EXERCISE-INDUCED DESATURATION IN THE QUADRICEPS MUSCLES OF ELITE COMPETITIVE ROWERS
    CHANCE, B
    DAIT, MT
    ZHANG, CD
    HAMAOKA, T
    HAGERMAN, F
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 262 (03): : C766 - C775
  • [5] The relationship between muscle deoxygenation and activation in different muscles of the quadriceps during cycle ramp exercise
    Chin, Lisa M. K.
    Kowalchuk, John M.
    Barstow, Thomas J.
    Kondo, Narihiko
    Amano, Tatsuro
    Shiojiri, Tomoyuki
    Koga, Shunsaku
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (05) : 1259 - 1265
  • [6] Effect of adipose tissue thickness, muscle site, and sex on near-infrared spectroscopy derived total-[hemoglobin plus myoglobin]
    Craig, Jesse C.
    Broxterman, Ryan M.
    Wilcox, Samuel L.
    Chen, Chixiang
    Barstow, Thomas J.
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2017, 123 (06) : 1571 - 1578
  • [7] ESTIMATION OF OPTICAL PATHLENGTH THROUGH TISSUE FROM DIRECT TIME OF FLIGHT MEASUREMENT
    DELPY, DT
    COPE, M
    VANDERZEE, P
    ARRIDGE, S
    WRAY, S
    WYATT, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (12) : 1433 - 1442
  • [8] OPTICAL PATHLENGTH MEASUREMENTS ON ADULT HEAD, CALF AND FOREARM AND THE HEAD OF THE NEWBORN-INFANT USING PHASE-RESOLVED OPTICAL SPECTROSCOPY
    DUNCAN, A
    MEEK, JH
    CLEMENCE, M
    ELWELL, CE
    TYSZCZUK, L
    COPE, M
    DELPY, DT
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (02) : 295 - 304
  • [9] Reduced Optical Path Length in the Vastus Lateralis During Ramp Cycling Exercise
    Endo, Tasuki
    Kime, Ryotaro
    Watanabe, Tsubasa
    Fuse, Sayuri
    Murase, Norio
    Kurosawa, Yuko
    Hamaoka, Takafumi
    [J]. OXYGEN TRANSPORT TO TISSUE XLI, 2020, 1232 : 239 - 244
  • [10] Evaluation of Functional Hyperemia Using NIRTRS Without the Influence of Fat Layer Thickness
    Endo, Tasuki
    Kime, Ryotaro
    Fuse, Sayuri
    Watanabe, Tsubasa
    Murase, Norio
    Kurosawa, Yuko
    Hamaoka, Takafumi
    [J]. OXYGEN TRANSPORT TO TISSUE XL, 2018, 1072 : 97 - 101