Accuracy of digital implant impressions in clinical studies: A systematic review

被引:56
作者
Schmidt, Alexander [1 ]
Woestmann, Bernd [1 ]
Schlenz, Maximiliane Amelie [1 ]
机构
[1] Justus Liebig Univ, Sch Dent Med, Dept Prosthodont, Schlangenzahl 14, D-35392 Giessen, Germany
关键词
clinical study; dental implants; dental impression technique; digital dentistry; dimensional measurement accuracy; intraoral scanner; IN-VIVO PRECISION; INTRAORAL SCANNERS; CONVENTIONAL IMPRESSIONS; FIXED PROSTHODONTICS; MULTIPLE IMPLANTS; DENTAL PROSTHESES; ARCH; POSITION; BODIES;
D O I
10.1111/clr.13951
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives The use of intraoral scanners (IOSs) for digital implant impressions in daily clinical practice is increasing. However, no structured literature review on the accuracy of digital implant impressions in clinical studies has been described to date. Therefore, this systematic review aimed to answer the PICO question: Which accuracy is described for digital implant impressions in clinical studies? Material and Methods An electronic database search was conducted in December 2021 using MeSH terms and free-text search. English-language studies addressing the accuracy of digital implant impressions in clinical studies involving at least 10 patients were included. All clinical indications were considered. Results Eight publications between 2014 and 2021 matched the review criteria. However, the study designs showed considerable differences. The number of implants within the studies ranged from 1 to 6, and the number of patients ranged from 10 to 39. The oldest study (2014) revealed the highest deviation for linear distances at 1000 +/- 650 mu m, whereas the other studies reported data in the range of 360 +/- 46 mu m to 40 +/- 20 mu m. In one study, no numerical data were reported and all studies compared digital and conventional implant impressions. Conclusions The number of clinical studies on the accuracy of digital implant impressions is low. Thus, the impact of different factors, such as the scanpath or scanbody, could not be identified. However, the accuracy of recent IOSs for digital implant impressions in patients was shown to be clinically acceptable. Nevertheless, the transfer error still needs to be considered when fabricating implant-supported restorations.
引用
收藏
页码:573 / 585
页数:13
相关论文
共 79 条
[1]   Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation [J].
Abduo, Jaafar ;
Palamara, Joseph E. A. .
INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
[2]   Accuracy of Intraoral Scanners: A Systematic Review of Influencing Factors [J].
Abduo, Jaafar ;
Elseyoufi, Mohamed .
EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2018, 26 (03) :101-121
[3]  
Afrashtehfar Kelvin I, 2016, Evid Based Dent, V17, P56, DOI [10.1038/sj.ebd.6401173, 10.1038/sj.ebd.6401173]
[4]   Digital Versus Conventional Impressions in Fixed Prosthodontics: A Review [J].
Ahlholm, Pekka ;
Sipila, Kirsi ;
Vallittu, Pekka ;
Jakonen, Minna ;
Kotiranta, Ulla .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (01) :35-41
[5]  
Alikhasi Marzieh, 2015, J Dent (Tehran), V12, P774
[6]   A Clinical Comparative Study of 3-Dimensional Accuracy between Digital and Conventional Implant Impression Techniques [J].
Alsharbaty, Mohammed Hussein M. ;
Alikhasi, Marzieh ;
Zarrati, Simindokht ;
Shamshiri, Ahmed Reza .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (04) :E902-E908
[7]  
Amezua-Lasuen Xabier, 2020, Advances in Design Engineering. Proceedings of the XXIX International Congress INGEGRAF. Lecture Notes in Mechanical Engineering (LNME), P202, DOI 10.1007/978-3-030-41200-5_22
[8]   Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: A pilot study [J].
Andriessen, Frank S. ;
Riikens, David R. ;
van der Meer, Wither J. ;
Wismeijer, Daniell W. .
JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (03) :186-194
[9]  
[Anonymous], 1994, Ann ICRP, V24, P1
[10]   Accuracy of an intraoral digital impression: A review [J].
Aswani, Kanchan ;
Wankhade, Sattyam ;
Khalikar, Arun ;
Deogade, Suryakant .
JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2020, 20 (01) :27-37