X-Tream dosimetry of synchrotron radiation with the PTW microDiamond

被引:16
作者
Davis, J. A. [1 ,2 ]
Petasecca, M. [1 ,2 ]
Cullen, A. [1 ]
Paino, J. R. [1 ]
Archer, J. [1 ]
Rosenfeld, A. B. [1 ,2 ]
Lerch, M. L. F. [1 ,2 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Northfields Ave, Wollongong, NSW, Australia
[2] Univ Wollongong, Illawarra Hlth & Med Res Inst, Northfields Ave, Wollongong, NSW, Australia
基金
澳大利亚国家健康与医学研究理事会;
关键词
Data acquisition concepts; Diamond Detectors; Dosimetry concepts and apparatus; Instrumentation for synchrotron radiation accelerators; THERAPY; BEAM;
D O I
10.1088/1748-0221/14/10/P10037
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this study, we demonstrate that the X-Tream dosimetry system developed by the Centre for Medical Radiation Physics can be used with both commercial and non-commercial dosimeters. A custom adaptor was constructed to connect the PTW microdiamond to the X-Tream DAQ. This allowed for the measurements of continuous depth dose curves, broad beam and microbeam profiles. The X-Tream system enables real time measurement of the instantaneous dose rate of synchrotron generated radiation with the PTW microDiamond. Finally, measurements undertaken in this study demonstrate that the X-Tream system is able to mitigate the alignment issue that has previously hampered the uptake of the PTW microdiamond in clinical quality assurance for small field dosimetry.
引用
收藏
页数:12
相关论文
共 13 条
[1]   Chalcone JAI-51 improves efficacy of synchrotron microbeam radiation therapy of brain tumors [J].
Bouchet, Audrey ;
Boumendjel, Ahcene ;
Khalil, Enam ;
Serduc, Raphael ;
Braeuer, Elke ;
Siegbahn, Erik Albert ;
Laissue, Jean A. ;
Boutonnat, Jean .
JOURNAL OF SYNCHROTRON RADIATION, 2012, 19 :478-482
[2]   PREFERENTIAL EFFECT OF SYNCHROTRON MICROBEAM RADIATION THERAPY ON INTRACEREBRAL 9L GLIOSARCOMA VASCULAR NETWORKS [J].
Bouchet, Audrey ;
Lemasson, Benjamin ;
Le Duc, Geraldine ;
Maisin, Cecile ;
Brauer-Krisch, Elke ;
Siegbahn, Erik Albert ;
Renaud, Luc ;
Khalil, Enam ;
Remy, Chantal ;
Poillot, Cathy ;
Bravin, Alberto ;
Laissue, Jean A. ;
Barbier, Emmanuel L. ;
Serduc, Raphael .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (05) :1503-1512
[3]   Spatial response of synthetic microDiamond and diode detectors measured with kilovoltage synchrotron radiation [J].
Butler, Duncan J. ;
Beveridge, Toby ;
Lehmann, Joerg ;
Oliver, Christopher P. ;
Stevenson, Andrew W. ;
Livingstone, Jayde .
MEDICAL PHYSICS, 2018, 45 (02) :943-952
[4]  
Curtis H J, 1967, Radiat Res Suppl, V7, P250, DOI 10.2307/3583718
[5]  
Dilmanian FA, 2002, NEURO-ONCOLOGY, V4, P26, DOI 10.1093/neuonc/4.1.26
[6]  
Laissue JA, 1998, INT J CANCER, V78, P654, DOI 10.1002/(SICI)1097-0215(19981123)78:5<654::AID-IJC21>3.0.CO
[7]  
2-L
[8]   Characterization of a synthetic single crystal diamond detector for dosimetry in spatially fractionated synchrotron x-ray fields [J].
Livingstone, Jayde ;
Stevenson, Andrew W. ;
Butler, Duncan J. ;
Hausermann, Daniel ;
Adam, Jean-Francois .
MEDICAL PHYSICS, 2016, 43 (07) :4283-4293
[9]   X-Tream: a novel dosimetry system for Synchrotron Microbeam Radiation Therapy [J].
Petasecca, M. ;
Cullen, A. ;
Fuduli, I. ;
Espinoza, A. ;
Porumb, C. ;
Stanton, C. ;
Aldosari, A. H. ;
Braeuer-Krisch, E. ;
Requardt, H. ;
Bravin, A. ;
Perevertaylo, V. ;
Rosenfeld, A. B. ;
Lerch, M. L. F. .
JOURNAL OF INSTRUMENTATION, 2012, 7
[10]   Brain tumor vessel response to synchrotron microbeam radiation therapy:: a short-term in vivo study [J].
Serduc, Raphael ;
Christen, Thomas ;
Laissue, Jean ;
Farion, Regine ;
Bouchet, Audrey ;
van der Sanden, Boudewijn ;
Segebarth, Christoph ;
Braeuer-Krisch, Elke ;
Le Duc, Geraldine ;
Bravin, Alberto ;
Remy, Chantal ;
Barbier, Emmanuel L. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (13) :3609-3622