Solid or partly solid solitary pulmonary nodules - Their characterization using contrast wash-in and morphologic features at helical CT

被引:35
作者
Lee, Kyung Soo
Yi, Chin A.
Jeong, Sun Young
Jeong, Yeon Joo
Kim, Seonwoo
Chung, Myung Jin
Kim, Ha Young
Kim, Yoon Kyung
Lee, Kwang Hwi
机构
[1] Sungkyunkwan Univ, Dept Radiol, Samsung Med Ctr, Sch Med, Seoul 135710, South Korea
[2] Sungkyunkwan Univ, Ctr Imaging Sci, Samsung Med Ctr, Sch Med, Seoul 135710, South Korea
[3] Sungkyunkwan Univ, Biostat Unit, Samsung Med Ctr, Sch Med, Seoul 135710, South Korea
[4] Pusan Natl Univ Hosp, Dept Radiol, Pusan, South Korea
基金
新加坡国家研究基金会;
关键词
CT scan; diagnosis; lung neoplasms;
D O I
10.1378/chest.06-2526
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Solitary pulmonary nodule (SPN) evaluation based on analyses of combined wash-in (WI) and washout (WO) values obtained by helical dynamic CT (HDCT) scanning is useful for malignant SPN characterization, because this method has higher specificity and accuracy than that based on analyses of WI values only. However, increased specificity results in reduced sensitivity and the missing of malignant SPNs. Thus, the purpose of this study was to seek the most effective method for SPN characterization during HDCT scanning. Methods: After obtaining unenhanced CT scans, dynamic CT scanning was performed using a helical technique (images were obtained at 30, 60, 90, and 120 s, and at 5 and 15 min after the initiation of IV contrast administration) in 486 patients with a solid or partly solid SPN. Diagnostic efficacies were compared for three approaches involving considerations of WI values (in Housfield units [HU]) only, both WI and WO HU values, and WI HU values and morphologic characteristics. Results: Considering WI values only (>= 25 HU), sensitivity, specificity, and accuracy for malignancy were 98% (233 of 237 nodules), 46% (114 of 249 nodules), and 71% (347 of 486 nodules), respectively. Using both a WI value of : 25 HU and a WO value of 5 to 36 HU, the corresponding values were 89% (212 of 237 nodules), 79% (197 of 249 nodules), and 84% (409 of 486 nodules), respectively; for a WI value of : 25 HU and a malignant morphology, the corresponding values were 92% (219 of 237 nodules), 79% (197 of 249 nodules), and 86% (416 of 486 nodules), respectively (these values were significantly different between the WI-only group and the other two groups; p = 0.001). Conclusions: The efficacy of SPN evaluation based on analyses of WI values plus morphologic features during HDCT scanning appears to be equivalent to that based on analyses of WI plus WO values, thus obviating the need for WO scans, which saves time and reduces radiation exposure of the patient.
引用
收藏
页码:1516 / 1525
页数:10
相关论文
共 15 条
[2]   Pulmonary sclerosing hemangioma presenting as solitary pulmonary nodule: Dynamic CT findings and histopathologic comparisons [J].
Chung, Myung Jin ;
Lee, Kyung Soo ;
Han, Joungho ;
Sung, Yon Mi ;
Chong, Semin ;
Kwon, O. Jung .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (02) :430-437
[3]   CHEST CT FOR KNOWN OR SUSPECTED LUNG-CANCER [J].
COLICE, GL .
CHEST, 1994, 106 (05) :1538-1550
[4]  
DORIO PJ, 1995, AM J ROENTGENOL, V165, P73
[5]   Solitary pulmonary nodules: Part I. Morphologic evaluation for differentiation of benign and malignant lesions [J].
Erasmus, JJ ;
Connolly, JE ;
McAdams, HP ;
Roggli, VL .
RADIOGRAPHICS, 2000, 20 (01) :43-58
[6]   Cost-effectiveness of alternative management strategies for patients with solitary pulmonary nodules [J].
Gould, MK ;
Sanders, GD ;
Barnett, PG ;
Rydzak, CE ;
Maclean, CC ;
McClellan, MB ;
Owens, DK .
ANNALS OF INTERNAL MEDICINE, 2003, 138 (09) :724-735
[7]   Solitary pulmonary nodules: Detection, characterization, and guidance for further diagnostic workup and treatment [J].
Jeong, Yeong Joo ;
Yi, Chin A. ;
Lee, Kyung Soo .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (01) :57-68
[8]   Solitary pulmonary nodule: Characterization with combined wash-in and washout features at dynamic multi-detector row CT [J].
Jeong, YJ ;
Lee, KS ;
Jeong, SY ;
Chung, MJ ;
Shim, SS ;
Kim, H ;
Kwon, OJ ;
Kim, S .
RADIOLOGY, 2005, 237 (02) :675-683
[9]   Development of a novel computer-aided diagnosis system for automatic discrimination of malignant from benign solitary pulmonary nodules on thin-section dynamic computed tomography [J].
Mori, K ;
Niki, N ;
Kondo, T ;
Kamiyama, Y ;
Kodama, T ;
Kawada, Y ;
Moriyama, N .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (02) :215-222
[10]   HELICAL CT OF THE LIVER - CLINICAL-APPLICATION OF AN AUTOMATED COMPUTER TECHNIQUE, SMARTPREP, FOR OBTAINING IMAGES WITH OPTIMAL CONTRAST ENHANCEMENT [J].
SILVERMAN, PM ;
ROBERTS, S ;
TEFFT, MC ;
BROWN, B ;
FOX, SH ;
COOPER, C ;
ZEMAN, RK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (01) :73-78