A non-contact camera-based method for respiratory rhythm extraction

被引:11
|
作者
Mateu-Mateus, M. [1 ]
Guede-Fernandez, F. [1 ]
Rodriguez-Ibanez, N. [2 ]
Garcia-Gonzalez, M. A. [1 ]
Ramos-Castro, J. [1 ]
Fernandez-Chimeno, M. [1 ]
机构
[1] Univ Politecn Cataluna, Dept Elect Engn, Barcelona 08034, Spain
[2] Ficosa Int SA, PI Can Mitjans S-N, Viladecavalls 08232, Barcelona, Spain
关键词
Non-contact; Camera-based; Respiration; Computer vision;
D O I
10.1016/j.bspc.2021.102443
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this work is to present a non-contact video-based method for respiratory rhythm extraction. The method makes use of a consumer-grade RGB camera, and it is based on computer vision algorithms to detect and track a custom pattern placed on the thorax of the subject. The respiratory signal is extracted by computing the changes in the position of the detected pattern through time. The method has been validated by comparing the extracted respiratory signal versus the one obtained with a reference method in adult population. The reference method was an inductive thorax plethysmography system (Respiband system from BioSignalsPlux (TM)). 21 healthy subjects were measured and four tests were performed for each subject. The respiratory signals and its respiratory cycles were extracted. To characterise the error, the respiratory cycles were assessed with: the Fisher intra-class correlation (ICC), mean absolute error (MAE), the mean absolute percentage error (MAPE) and four Bland-Altman plots were obtained. The results show a > 0.9 correlation for controlled respiration and > 0.85 for unconstrained respiration between the proposed method and the reference method, with low error results (MAPE < 4% for constrained respiration and < 6% for unconstrained respiration) and with a high sensitivity when detecting the respiratory cycles (> 94% in all cases). From the obtained results we can conclude that the proposed algorithm is adequate to acquire the respiratory signal for rhythm extraction, in real-time with a high performance when compared with the reference method, and that it could be applied to real-life situations.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Non-contact respiratory rate and heart rate signal acquisition system
    Guo J.
    Chen Y.-H.
    Wang L.-R.
    Wei Y.
    Guo Y.
    Zhao Y.-M.
    Liu L.-L.
    Chen X.-H.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2019, 27 (06): : 1354 - 1361
  • [32] A self-calibration method of non-contact voltage measurement based on impedance transformation
    Huang R.
    Suo C.
    Zhang W.
    Zhu J.
    Zou X.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2023, 44 (03): : 137 - 145
  • [33] Non-contact Vehicle Weighing Method Based on Tire Deformation Using Image Recognition
    Kong X.
    Zhang J.
    Wang T.-Y.
    Tang H.-D.
    Huang Q.-X.
    Deng L.
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2022, 35 (08): : 186 - 193
  • [34] Non-contact vehicle weighing method based on tire-road contact model and computer vision techniques
    Kong, Xuan
    Zhang, Jie
    Wang, Tengyi
    Deng, Lu
    Cai, C. S.
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2022, 174
  • [35] Non-Contact Heart-Rate Measurement Method Using Both Transmitted Wave Extraction and Wavelet Transform
    Yang, Zheng
    Mitsui, Kazutaka
    Wang, Jianqing
    Saito, Takashi
    Shibata, Shunsuke
    Mori, Hiroyuki
    Ueda, Goro
    SENSORS, 2021, 21 (08)
  • [36] Non-Contact Eddy Current Excitation Method for Vibration Testing
    H. A. Sodano
    Experimental Mechanics, 2006, 46 : 627 - 635
  • [37] Non-contact ECG Monitoring Based on Capacitive Electrodes
    ZHOU Ping
    LI Zhou-cheng
    WANG Feng
    JIAO Hong-yu
    ChineseJournalofBiomedicalEngineering, 2012, 21 (03) : 98 - 103
  • [38] Design of a Tribotester Based on Non-Contact Displacement Measurements
    Kim, Chang-Lae
    Sung, Yoon-Gyung
    MICROMACHINES, 2019, 10 (11)
  • [39] Non-Contact Measurement Device based on Ultrasonic Technology
    Lan, Zhenping
    Meng, Huimin
    Li, Jintao
    Wang, Yuru
    Li, Ping
    Jin, Jiyu
    MECHATRONICS ENGINEERING, COMPUTING AND INFORMATION TECHNOLOGY, 2014, 556-562 : 2654 - 2657
  • [40] Dynamic detection method for non-contact vehicle wheelbase difference
    Shan H.
    Wu D.
    Zhang L.
    Su J.
    Zhang, Libin (zlb@jlu.edu.cn), 1600, Central South University of Technology (48): : 2959 - 2965