A non-contact camera-based method for respiratory rhythm extraction

被引:11
|
作者
Mateu-Mateus, M. [1 ]
Guede-Fernandez, F. [1 ]
Rodriguez-Ibanez, N. [2 ]
Garcia-Gonzalez, M. A. [1 ]
Ramos-Castro, J. [1 ]
Fernandez-Chimeno, M. [1 ]
机构
[1] Univ Politecn Cataluna, Dept Elect Engn, Barcelona 08034, Spain
[2] Ficosa Int SA, PI Can Mitjans S-N, Viladecavalls 08232, Barcelona, Spain
关键词
Non-contact; Camera-based; Respiration; Computer vision;
D O I
10.1016/j.bspc.2021.102443
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this work is to present a non-contact video-based method for respiratory rhythm extraction. The method makes use of a consumer-grade RGB camera, and it is based on computer vision algorithms to detect and track a custom pattern placed on the thorax of the subject. The respiratory signal is extracted by computing the changes in the position of the detected pattern through time. The method has been validated by comparing the extracted respiratory signal versus the one obtained with a reference method in adult population. The reference method was an inductive thorax plethysmography system (Respiband system from BioSignalsPlux (TM)). 21 healthy subjects were measured and four tests were performed for each subject. The respiratory signals and its respiratory cycles were extracted. To characterise the error, the respiratory cycles were assessed with: the Fisher intra-class correlation (ICC), mean absolute error (MAE), the mean absolute percentage error (MAPE) and four Bland-Altman plots were obtained. The results show a > 0.9 correlation for controlled respiration and > 0.85 for unconstrained respiration between the proposed method and the reference method, with low error results (MAPE < 4% for constrained respiration and < 6% for unconstrained respiration) and with a high sensitivity when detecting the respiratory cycles (> 94% in all cases). From the obtained results we can conclude that the proposed algorithm is adequate to acquire the respiratory signal for rhythm extraction, in real-time with a high performance when compared with the reference method, and that it could be applied to real-life situations.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Video based non-contact monitoring of respiratory rate and chest indrawing in children with pneumonia
    Lucy, Ferdous Karim
    Suha, Khadiza Tun
    Dipty, Sumaiya Tabassum
    Wadud, Md Sharjis Ibne
    Kadir, Muhammad Abdul
    PHYSIOLOGICAL MEASUREMENT, 2021, 42 (10)
  • [22] Neonatal non-contact respiratory monitoring based on real-time infrared thermography
    Abbas K Abbas
    Konrad Heimann
    Katrin Jergus
    Thorsten Orlikowsky
    Steffen Leonhardt
    BioMedical Engineering OnLine, 10
  • [23] Non-contact respiratory monitoring system using a ceiling-attached microwave antenna
    Uenoyama, Maki
    Matsui, Takemi
    Yamada, Kouske
    Suzuki, Satoshi
    Takase, Bonpei
    Suzuki, Shinya
    Ishihara, Masayuki
    Kawakami, Mitsuyuki
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (09) : 835 - 840
  • [24] Non-contact respiratory monitoring system using a ceiling-attached microwave antenna
    Maki Uenoyama
    Takemi Matsui
    Kouske Yamada
    Satoshi Suzuki
    Bonpei Takase
    Shinya Suzuki
    Masayuki Ishihara
    Mitsuyuki Kawakami
    Medical and Biological Engineering and Computing, 2006, 44 : 835 - 840
  • [25] Non-contact Measurement of Respiratory and Heart Rates Using a CMOS Camera-equipped Infrared Camera for Prompt Infection Screening at Airport Quarantine Stations
    Nakayama, Yosuke
    Sun, Guanghao
    Abe, Shigeto
    Matsui, Takemi
    2015 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND VIRTUAL ENVIRONMENTS FOR MEASUREMENT SYSTEMS AND APPLICATIONS (CIVEMSA), 2015, : 27 - 30
  • [26] Energy Efficiency Measurement of Mechanical Crushing Based on Non-Contact Identification Method
    Lu, Xiaoquan
    Duan, Meimei
    Su, Huiling
    Li, Bo
    Liu, Ying
    SYMMETRY-BASEL, 2024, 16 (07):
  • [27] The infrared image based non-contact monitoring of respiratory waveform through deep Kalman filter
    Sun, Hao
    Huang, Zhipei
    Tong, Yonggang
    Shan, Guangcun
    Dai, Xuewu
    Qin, Fei
    2024 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS, MEMEA 2024, 2024,
  • [28] An Approach to Non-contact Monitoring of Respiratory Rate and Breathing Pattern Based on Slow Motion Images
    Jakkaew, Prasara
    Onoye, Takao
    2019 4TH IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS - ASIA (IEEE ICCE-ASIA 2019), 2019, : 47 - 51
  • [29] Double-network conductive hydrogel for non-contact respiratory monitoring
    Deng, Shuhang
    Ming, Xiaoran
    Yan, Guilong
    Wang, Li
    Li, Zhenyu
    Chen, Jingyu
    Lai, Jingjuan
    Li, Dong
    Xiang, Dong
    Zhao, Chunxia
    Li, Hui
    Zhang, Xuezhong
    Li, Han
    Wang, Xungai
    Xiao, Yu
    Wu, Yuanpeng
    CHEMICAL ENGINEERING JOURNAL, 2024, 502
  • [30] The Non-Contact Respiratory Monitoring System Using Thermal Image Processing
    Chiang, Ta-Chi
    Tung, Meng-Hsiung
    Hendrick
    Kurniadi, Dedi
    Wang, Zhi-hao
    Jong, Gwo-Jia
    2016 3RD INTERNATIONAL CONFERENCE ON GREEN TECHNOLOGY AND SUSTAINABLE DEVELOPMENT (GTSD), 2016, : 86 - 92