Regenerable ZnO/GaAs Bulk Acoustic Wave Biosensor for Detection of Escherichia coli in "Complex" Biological Medium

被引:10
作者
Chawich, Juliana [1 ,2 ]
Hassen, Walid M. [1 ]
Elie-Caille, Celine [2 ]
Leblois, Therese [2 ]
Dubowski, Jan J. [1 ]
机构
[1] Univ Sherbrooke, Lab Quantum Semicond & Photon Based BioNanotechno, Interdisciplinary Inst Technol Innovat 3IT, CNRS,Lab Nanotechnol Nanosyst LN2,UMI 3463, Sherbrooke, PQ J1K 0A5, Canada
[2] Univ Bourgogne Franche Comte, CNRS, FEMTO ST Inst, UMR 6174, F-25030 Besancon, France
来源
BIOSENSORS-BASEL | 2021年 / 11卷 / 05期
基金
加拿大自然科学与工程研究理事会;
关键词
regenerable biosensor; bulk acoustic waves; piezoelectric ZnO thin film; GaAs membrane; self-assembled monolayers; bacteria detection; Escherichia coli; PATHOGENIC BACTERIA; RECENT PROGRESS; SURFACE; GAAS; MICROSCOPY; OUTBREAK; PHASE; LAYER; FILMS; WATER;
D O I
10.3390/bios11050145
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A regenerable bulk acoustic wave (BAW) biosensor is developed for the rapid, label-free and selective detection of Escherichia coli in liquid media. The geometry of the biosensor consists of a GaAs membrane coated with a thin film of piezoelectric ZnO on its top surface. A pair of electrodes deposited on the ZnO film allows the generation of BAWs by lateral field excitation. The back surface of the membrane is functionalized with alkanethiol self-assembled monolayers and antibodies against E. coli. The antibody immobilization was investigated as a function of the concentration of antibody suspensions, their pH and incubation time, designed to optimize the immunocapture of bacteria. The performance of the biosensor was evaluated by detection tests in different environments for bacterial suspensions ranging between 10(3) and 10(8) CFU/mL. A linear dependence between the frequency response and the logarithm of E. coli concentration was observed for suspensions ranging between 10(3) and 10(7) CFU/mL, with the limit of detection of the biosensor estimated at 10(3) CFU/mL. The 5-fold regeneration and excellent selectivity towards E. coli detected at 10(4) CFU/mL in a suspension tinted with Bacillus subtilis at 10(6) CFU/mL illustrate the biosensor potential for the attractive operation in complex biological media.
引用
收藏
页数:15
相关论文
共 48 条
[1]   Biosensors for Whole-Cell Bacterial Detection [J].
Ahmed, Asif ;
Rushworth, Jo V. ;
Hirst, Natalie A. ;
Millner, Paul A. .
CLINICAL MICROBIOLOGY REVIEWS, 2014, 27 (03) :631-646
[2]   A Highly Sensitive Impedimetric DNA Biosensor Based on Hollow Silica Microspheres for Label-Free Determination of E. coli [J].
Ariffin, Eda Yuhana ;
Heng, Lee Yook ;
Tan, Ling Ling ;
Abd Karim, Nurul Huda ;
Hasbullah, Siti Aishah .
SENSORS, 2020, 20 (05)
[3]   A Fluidic Interface with High Flow Uniformity for Reusable Large Area Resonant Biosensors [J].
Azzopardi, Charles-Louis ;
Lacour, Vivien ;
Manceau, Jean-Francois ;
Barthes, Magali ;
Bonnet, Dimitri ;
Chollet, Franck ;
Leblois, Therese .
MICROMACHINES, 2017, 8 (10)
[4]  
Ballantine D.S., 1996, Acoustic Wave Sensors: Theory, Design and Physico-Chemical Applications
[5]   AMIDE MODES AND PROTEIN CONFORMATION [J].
BANDEKAR, J .
BIOCHIMICA ET BIOPHYSICA ACTA, 1992, 1120 (02) :123-143
[6]   RECONSTITUTION OF A PROTEIN MONOLAYER ON THIOLATES FUNCTIONALIZED GaAs SURFACE [J].
Bienaime, A. ;
Leblois, T. ;
Lucchi, G. ;
Blondeau-Patissier, V. ;
Ducoroy, P. ;
Boireau, W. ;
Elie-Caille, C. .
INTERNATIONAL JOURNAL OF NANOSCIENCE, 2012, 11 (04)
[7]   Design and microfabrication of a lateral excited gallium arsenide biosensor [J].
Bienaime, A. ;
Liu, L. ;
Elie-Caille, C. ;
Leblois, T. .
EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2012, 57 (02)
[8]   Influence of a Thiolate Chemical Layer on GaAs (100) Biofunctionalization: An Original Approach Coupling Atomic Force Microscopy and Mass Spectrometry Methods [J].
Bienaime, Alex ;
Leblois, Therese ;
Gremaud, Nicolas ;
Chaudon, Maxime-Jean ;
El Osta, Marven ;
Pecqueur, Delphine ;
Ducoroy, Patrick ;
Elie-Caille, Celine .
MATERIALS, 2013, 6 (11) :4946-4966
[9]   Micro Structuration of GaAs Surface by Wet Etching: Towards a Specific Surface Behavior [J].
Bienaime, Alex ;
Elie-Caille, Celine ;
Leblois, Therese .
JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2012, 12 (08) :6855-6863
[10]   Effects of the piezoelectric field on the modulation of exciton-polaritons by surface acoustic waves [J].
Cerda-Mendez, E. A. ;
Krizhanovskii, D. ;
Biermann, K. ;
Hey, R. ;
Santos, P. V. ;
Skolnick, M. S. .
SUPERLATTICES AND MICROSTRUCTURES, 2011, 49 (03) :233-240