Method development for the separation of steroids by capillary electrochromatography

被引:8
作者
Jiskra, J
Claessens, HA
Cramers, CA
机构
[1] Eindhoven Univ Technol, Dept Polymer Chem, Instrumental Anal Lab, NL-5600 MB Eindhoven, Netherlands
[2] Synthon BV, NL-6503 GN Nijmegen, Netherlands
[3] Eindhoven Univ Technol, Dept Chem Engn & Chem, Instrumental Anal Lab, NL-5600 MB Eindhoven, Netherlands
来源
JOURNAL OF SEPARATION SCIENCE | 2002年 / 25卷 / 18期
关键词
capillary electrochromatography (CEC); steroids; method development;
D O I
10.1002/jssc.200290005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid capillary electrochromatography (CEC) method was developed to separate five structurally related steroid compounds from the production line of steroid hormones. The separation was performed on a Hypersil C8 MOS and Unimicro C18 stationary phases using acetonitrile (ACN), methanol (MeOH), and tetrahydrofuran (THF) as organic modifiers and tris(hydroxymethyl)aminomethane (Tris) as buffer additive. The Hypersil C8 MOS stationary phase performed best together with ACN as organic modifier and Tris buffer. The method was extensively tested for ruggedness with respect to sensitivity to temperature, ACN composition, pH change, concentration of Tris buffer, injected plug length, and run-to-run and day-to-day repeatability. The minimal detectable concentration and amount were investigated for quantification purposes. The developed CEC method was shown to be fast, rugged, and well suited for quantification of the steroids under study.
引用
收藏
页码:1337 / 1345
页数:9
相关论文
共 19 条
  • [1] BACZEK T, 2001, LC GC EUR, V14, P304
  • [2] Some considerations concerning the composition of the mobile phase in capillary electrochromatography
    Banholczer, A
    Pyell, U
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) : 363 - 374
  • [3] Capillary electrochromatography in the pharmaceutical industry. Practical reality or fantasy?
    Euerby, MR
    Johnson, CM
    Bartle, KD
    Myers, P
    Roulin, SCP
    [J]. ANALYTICAL COMMUNICATIONS, 1996, 33 (11): : 403 - 405
  • [4] Euerby MR, 1997, J MICROCOLUMN SEP, V9, P373
  • [5] EUERBY MR, 1998, LC GC EUR, V11, P39
  • [6] International Union of Pure and Applied Chemistry, 1979, NOM ORG CHEM
  • [7] Chromatographic properties of reversed-phase stationary phases under pressure- and electro-driven conditions
    Jiskra, J
    Cramers, CA
    Byelik, M
    Claessens, HA
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 862 (02) : 121 - 135
  • [8] Tapers and restrictors for capillary electrochromatography and capillary electrochromatography mass spectrometry
    Lord, GA
    Gordon, DB
    Myers, P
    King, BW
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1997, 768 (01) : 9 - 16
  • [9] Poole C.F., 1991, CHROMATOGRAPHY TODAY
  • [10] Influence of sample plug width in capillary electrochromatography
    Pyell, U
    Rebscher, H
    Banholczer, A
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1997, 779 (1-2) : 155 - 163