Biomechanically Constrained Groupwise US to CT Registration of the Lumbar Spine

被引:0
作者
Gill, Sean [1 ]
Mousavi, Parvin [1 ]
Fichtinger, Gabor [1 ]
Chen, Elvis [1 ]
Boisvert, Jonathan [1 ]
Pichora, David [1 ]
Abolmaesumi, Purang [1 ]
机构
[1] Queens Univ, Kingston, ON, Canada
来源
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2009, PT I, PROCEEDINGS | 2009年 / 5761卷
基金
加拿大健康研究院;
关键词
MEDICAL ULTRASOUND; SIMULATION; IMAGES;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Registration of intraoperative ultrasound (US) with preoperative computed tomography (CT) data for interventional guidance is a subject of immense interest, Particularly for percutaneous spinal injections. Propose a biomechanically constrained group-wise registration of US to CT. images of the lumbar spine. Each vertebra in CT is treated as a sub-volume and transformed individually. The sub-volumes are then reconstructed into a single volume. The algorithm simulates an US image front the CT data at. each iteration of the registration. This simulated US image is used to calculate an intensity based similarity metric with the real US image. A biomechanical model is used to constrain the displacement of the vertebrae relative to one another. Covariance Matrix Adaption - Evolution Strategy (CMA-ES) is utilized its the optimization strategy. Validation is Performed on CT and US images from a phantom designed 110 Preserve realistic curvatures of the spine. The technique is able to register initial misalignments of up to 20mm with a success rate of 82%, and those, of up to 10mm with a success rate of 98.6%.
引用
收藏
页码:803 / 810
页数:8
相关论文
共 11 条
[1]  
CHEN TK, 2008, REAL TIME ULTRASOUND, V6918
[2]   Simulation of an anterior spine instrumentation in adolescent idiopathic scoliosis using a flexible multi-body model [J].
Desroches, Genevieve ;
Aubin, Carl-Eric ;
Sucato, Daniel J. ;
Rivard, Charles-Hilaire .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2007, 45 (08) :759-768
[3]  
GILL S, 2009, GROUP WISE REGISTRAT, V7261
[4]  
KUTTER O, 2009, GPU BASED FRAMEWORK, V7261
[5]   Tissue-mimicking agar/gelatin materials for use in heterogeneous elastography phantoms [J].
Madsen, EL ;
Hobson, MA ;
Shi, HR ;
Varghese, T ;
Frank, GR .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (23) :5597-5618
[6]   Cadaver validation of intensity-based ultrasound to CT registration [J].
Penney, G. P. ;
Barratt, D. C. ;
Chan, C. S. K. ;
Slomczykowski, M. ;
Carter, T. J. ;
Edwards, P. J. ;
Hawkes, D. J. .
MEDICAL IMAGE ANALYSIS, 2006, 10 (03) :385-395
[7]  
REICHL T, 2009, ULTRASOUND GOES GPU, V7261
[8]  
Shams R, 2008, LECT NOTES COMPUT SC, V5242, P734, DOI 10.1007/978-3-540-85990-1_88
[9]   Automatic CT-ultrasound registration for diagnostic imaging and image-guided intervention [J].
Wein, Wolfgang ;
Brunke, Shelby ;
Khamene, Ali ;
Callstrom, Matthew R. ;
Navab, Nassir .
MEDICAL IMAGE ANALYSIS, 2008, 12 (05) :577-585
[10]  
Wein W, 2007, LECT NOTES COMPUT SC, V4791, P136