Assessment of a Non-Invasive Brain Oximeter in a Sheep Model of Acute Brain Injury

被引:5
作者
Dixon, Barry [1 ]
Turner, Renee [2 ]
Christou, Chris [3 ]
机构
[1] Cyban Pty Ltd, Melbourne, Vic, Australia
[2] Univ Adelaide, Adelaide Med Sch, Adelaide, SA, Australia
[3] South Australian Hlth & Med Res Inst Adelaide, Preclin Imaging & Res Labs, Adelaide, SA, Australia
关键词
oximetry; traumatic brain injury; brain; sheep; NEAR-INFRARED SPECTROSCOPY; CEREBRAL-BLOOD-FLOW; VENOUS-BLOOD; TISSUE OXYGEN; EXTRACRANIAL CONTAMINATION; PRESSURE; ARTERIAL; SATURATION; PERFUSION; VESSELS;
D O I
10.2147/MDER.S235804
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Introduction: Evidence suggests treatments guided by brain oxygen levels improve patient outcomes following severe traumatic brain injury; however, brain oxygen levels are not routinely monitored as an effective non-invasive method has not been established. We undertook a study, in a sheep model of acute brain injury, to assess a new non-invasive brain oximeter. The monitor uses the principles of pulse oximetry to record a pulse and oxygen levels. Methods: We studied 8 sheep. An acute increase in intracranial pressure was induced with an injection of blood into the cranial vault. The temporal changes in the brain oximeter, intracranial pressure and cerebral perfusion pressure were recorded. Simultaneous conventional skin pulse oximetry was also recorded to assess the possible influence of skin blood flow on the brain oximeter signal. Results: At baseline, a pulsatile waveform consistent with the brain circulation was obtained in 7 animals. The baseline brain pulse was quite distinct from the simultaneous conventional skin pulse and similar in shape to a central venous pressure waveform. Injection of blood into the cranial vault triggered an immediate increase in intracranial pressure and fall in cerebral perfusion pressure, by 60-s cerebral perfusion pressure recovered. The brain oximeter oxygen levels demonstrated similar changes with an immediate fall and recovery by 60 s. Periods of high intracranial pressure were also associated with high-frequency oscillations in the brain pulse waveform; there was, however, no change in the conventional skin pulse oximeter pulse waveform. Conclusion: The brain oximeter detected acute changes in both oxygen levels and the brain pulse waveform following an increase in intracranial pressure levels. The brain oximeter could assist clinicians in the management of acute brain injury.
引用
收藏
页码:479 / 487
页数:9
相关论文
共 34 条
[1]   Brain Monitoring: Do We Need a Hole? An Update on Invasive and Noninvasive Brain Monitoring Modalities [J].
Barone, D. G. ;
Czosnyka, M. .
SCIENTIFIC WORLD JOURNAL, 2014,
[2]   Accuracy of two pulse oximeters at low arterial hemoglobin-oxygen saturation [J].
Carter, BG ;
Carlin, JB ;
Tibballs, J ;
Mead, H ;
Hochmann, M ;
Osborne, A .
CRITICAL CARE MEDICINE, 1998, 26 (06) :1128-1133
[3]   Impact of Extracranial Contamination on Regional Cerebral Oxygen Saturation A Comparison of Three Cerebral Oximetty Technologies [J].
Davie, Sophie N. ;
Grocott, Hilary P. .
ANESTHESIOLOGY, 2012, 116 (04) :834-840
[4]   Retinal venous oxygen saturation and cardiac output during controlled hemorrhage and resuscitation [J].
Denninghoff, KR ;
Smith, MH ;
Lompado, A ;
Hillman, LW .
JOURNAL OF APPLIED PHYSIOLOGY, 2003, 94 (03) :891-896
[5]   CHRONIC CATHETERIZATION FOR SAMPLING VENOUS-BLOOD FROM BRAIN OF SHEEP [J].
HALES, JRS .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1972, 337 (01) :81-&
[6]   Topology and hemodynamics of the cortical cerebrovascular system [J].
Hirsch, Sven ;
Reichold, Johannes ;
Schneider, Matthias ;
Szekelyi, Gabor ;
Weber, Bruno .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2012, 32 (06) :952-967
[7]   TRANS-CUTANEOUS OXYGEN-TENSION MEASUREMENTS DURING HEMORRHAGIC HYPOPERFUSION USING TRENDELENBURG AND THE PNEUMATIC ANTISHOCK GARMENT [J].
JAFFURS, W ;
SPICER, SS ;
CARROLL, RG ;
ALLISON, EJ ;
WHITLEY, TW ;
MAYO, HL .
RESUSCITATION, 1989, 17 (02) :119-129
[8]   RAISED INTRACRANIAL PRESSURE AND CEREBRAL BLOOD-FLOW .1. CISTERNA MAGNA INFUSION IN PRIMATES [J].
JOHNSTON, IH ;
JENNETT, WB ;
ROWAN, JO ;
HARPER, AM .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1972, 35 (03) :285-&
[9]   Effect of posture and extracranial contamination on results of cerebral oximetry by near-infrared spectroscopy [J].
Kato, Shinya ;
Yoshitani, Kenji ;
Kubota, Yosuke ;
Inatomi, Yuzuru ;
Ohnishi, Yoshihiko .
JOURNAL OF ANESTHESIA, 2017, 31 (01) :103-110
[10]   Noninvasive intracranial compliance monitoring - Technical note and clinical results [J].
Lang, EW ;
Paulat, K ;
Witte, C ;
Zolondz, J ;
Mehdorn, HM .
JOURNAL OF NEUROSURGERY, 2003, 98 (01) :214-218