摘要
Post-combustion CO2 capture and storage (CCS) presents a promising strategy to capture, compress, transport and store CO2 from a high volume-low pressure flue gas stream emitted from a fossil fuel-fired power plant. This work undertakes the simulation of CO2 capture and compression integration into an 800 MW supercritical coal-fired power plant using chemical process simulators. The focus is not only on the simulation of full load of flue gas stream into the CO2 capture and compression, but also, on the impact of a partial load. The result reveals that the energy penalty of a low capture efficiency, for example, at 50% capture efficiency with 10% flue gas load is higher than for 90% flue gas load at the equivalent capture efficiency by about 440 kWh(e)/tonne CO2. The study also addresses the effect of CO2 capture performance by different coal ranks. It is found that lignite pulverized coal (PC)-fired power plant has a higher energy requirement than subbituminous and bituminous PC-fired power plants by 40.1 and 98.6 MWe, respectively. In addition to the investigation of energy requirement, other significant parameters including energy penalty, plant efficiency, amine flow rate and extracted steam flow rate, are also presented. The study reveals that operating at partial load, for example at half load with 90% CO2 capture efficiency, as compared with full load, reduces the energy penalty, plant efficiency drop, amine flow rate and extracted steam flow rate by 9.9%, 24.4%, 50.0% and 49.9%, respectively. In addition, the effect of steam extracted from different locations from a series of steam turbine with the objective to achieve the lowest possible energy penalty is evaluated. The simulation shows that a low extracted steam pressure from a series of steam turbines, for example at 300 kPa, minimizes the energy penalty by up to 25.3%. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:499 / 510
页数:12
相关论文
共 34 条
[1]   CO2 capture from power plants.: Part I.: A parametric study of the technical-performance based on monoethanolamine [J].
Abu-Zahra, Mohammad R. M. ;
Schneiders, Leon H. J. ;
Niederer, John P. M. ;
Feron, Paul H. M. ;
Versteeg, Geert F. .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2007, 1 (01) :37-46
[2]  
[Anonymous], GREENHOUSE GAS CONTR
[3]  
[Anonymous], 2008, International energy outlook
[4]  
[Anonymous], 2016, CARBON DIOXIDE CAPTU
[5]  
[Anonymous], 2006, KEY WORLD EN STAT
[6]  
[Anonymous], P 8 INT C GREENH GAS
[7]   Integration of CO2 capture unit using single- and blended-amines into supercritical coal-fired power plants:: Implications for emission and energy management [J].
Aroonwilas, Adisorn ;
Veawab, Amornuadee .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2007, 1 (02) :143-150
[8]  
Couper J. R., 2005, CHEM PROCESS EQUIPME
[9]  
Dooley JJ., 2009, ASSESSMENT COMMERCIA
[10]   Absorber model for CO2 capture by monoethanolamine - application to CASTOR pilot results [J].
Dugas, Ross ;
Alix, Pascal ;
Lemaire, Eric ;
Broutin, Paul ;
Rochelle, Gary .
GREENHOUSE GAS CONTROL TECHNOLOGIES 9, 2009, 1 (01) :103-107