Wall Shear Stress Assessment of the False Lumen in Acute Type B Aortic Dissection Visualized by 4-Dimensional Flow Magnetic Resonance Imaging: An Ex-Vivo Study

被引:8
作者
Veger, Hugo T. C. [1 ]
Pasveer, Erik H. [1 ]
Westenberg, Jos J. M. [2 ]
Wever, Jan J. [1 ]
van Eps, Randolph G. Statius [1 ]
机构
[1] Haga Teaching Hosp, Dept Vasc Surg, Els Borst Eilerspl 275, NL-2545 AA The Hague, Netherlands
[2] Leiden Univ, Dept Radiol, Med Ctr, Leiden, Netherlands
关键词
aortic dissection; type B; four-dimensional flow magnetic resonance imaging; ex-vivo; THORACIC AORTA; TEAR SIZE; MANAGEMENT; QUANTIFICATION; PRESSURE; PORCINE; MOTION; MODEL;
D O I
10.1177/15385744211017117
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Four-dimensional flow magnetic resonance imaging (4D flow MRI) can accurately visualize and quantify flow and provide hemodynamic information such as wall shear stress (WSS). This imaging technique can be used to obtain more insight in the hemodynamic changes during cardiac cycle in the true and false lumen of uncomplicated acute Type B Aortic Dissection (TBAD). Gaining more insight of these forces in the false lumen in uncomplicated TBAD during optimal medical treatment, might result in prediction of adverse outcomes. Methods: A porcine aorta dissection model with an artificial dissection was positioned in a validated ex-vivo circulatory system with physiological pulsatile flow. 4D flow MR images with 3 set heartrates (HR; 60 bpm, 80 bpm and 100 bpm) were acquired. False lumen volume per cycle (FLV), mean and peak systolic WSS were determined from 4D flow MRI data. For validation, the experiment was repeated with a second porcine aorta dissection model. Results: During both experiments an increase in FLV (initial experiment: Delta FLV = 2.05 ml, p < 0.001, repeated experiment: Delta FLV = 1.08 ml, p = 0.005) and peak WSS (initial experiment: Delta WSS = 1.2 Pa, p = 0.004, repeated experiment: Delta WSS = 1.79 Pa, p = 0.016) was observed when HR increased from 60 to 80 bpm. Raising the HR from 80 to 100 bpm, no significant increase in FLV (p = 0.073, p = 0.139) was seen during both experiments. The false lumen mean WSS increased significant during initial (2.71 to 3.85 Pa; p = 0.013) and non-significant during repeated experiment (3.22 to 4.00 Pa; p = 0.320). Conclusion: 4D flow MRI provides insight into hemodynamic dimensions including WSS. Our ex-vivo experiments showed that an increase in HR from 60 to 80 bpm resulted in a significant increase of FLV and WSS of the false lumen. We suggest that strict heart rate control is of major importance to reduce the mean and peak WSS in uncomplicated acute TBAD. Because of the limitations of an ex-vivo study, 4D flow MRI will have to be performed in clinical setting to determine whether this imaging model would be of value to predict the course of uncomplicated TBAD.
引用
收藏
页码:696 / 701
页数:6
相关论文
共 25 条
  • [11] Endovascular management of acute aortic dissection
    Khayat, Mamdouh
    Cooper, Kyle J.
    Khaja, Minhaj S.
    Gandhi, Ripal
    Bryce, Yolanda C.
    Williams, David M.
    [J]. CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2018, 8 : S97 - S107
  • [12] Dynamic MR angiography in acute aortic dissection
    Kinner, Sonja
    Eggebrecht, Holger
    Maderwald, Stefan
    Barkhausen, Joerg
    Ladd, Susanne C.
    Quick, Harald H.
    Hunold, Peter
    Vogt, Florian M.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (02) : 505 - 514
  • [13] Management of complicated and uncomplicated acute type B dissection. A systematic review and meta-analysis
    Moulakakis, Konstantinos G.
    Mylonas, Spyridon N.
    Dalainas, Ilias
    Kakisis, John
    Kotsis, Thomas
    Liapis, Christos D.
    [J]. ANNALS OF CARDIOTHORACIC SURGERY, 2014, 3 (03) : 234 - 246
  • [14] Changing Pathology of the Thoracic Aorta From Acute to Chronic Dissection Literature Review and Insights
    Peterss, Sven
    Mansour, Ahmed M.
    Ross, Julia A.
    Vaitkeviciute, Irena
    Charilaou, Paris
    Dumfarth, Julia
    Fang, Hai
    Ziganshin, Bulat A.
    Rizzo, John A.
    Adeniran, Adebowale J.
    Elefteriades, John A.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (10) : 1054 - 1065
  • [15] Ex-vivo Haemodynamic Models for the Study of Stanford Type B Aortic Dissection in Isolated Porcine Aorta
    Qing, K. -X.
    Chan, Y. C.
    Lau, S. F.
    Yiu, W. -K.
    Ting, A. C. W.
    Cheng, S. W. K.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2012, 44 (04) : 399 - 405
  • [16] An in vitro phantom study on the influence of tear size and configuration on the hemodynamics of the lumina in chronic type B aortic dissections
    Rudenick, Paula A.
    Bijnens, Bart H.
    Garcia-Dorado, David
    Evangelista, Arturo
    [J]. JOURNAL OF VASCULAR SURGERY, 2013, 57 (02) : 464 - +
  • [17] Management of Descending Thoracic Aorta Disease: Evolving Treatment Paradigms in the TEVAR Era
    Schermerhorn, M. L.
    Jones, D. W.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2017, 53 (01) : 1 - 3
  • [18] Contemporary Management of Acute Type B Dissection
    Scott, A. J.
    Bicknell, C. D.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2016, 51 (03) : 452 - 459
  • [19] Tear size and location impacts false lumen pressure in an ex vivo model of chronic type B aortic dissection
    Tsai, Thomas T.
    Schlicht, Marty S.
    Khanafer, Khalil
    Bull, Joseph L.
    Valassis, Doug T.
    Williams, David M.
    Bergner, Ramon
    Eagle, Kim A.
    [J]. JOURNAL OF VASCULAR SURGERY, 2008, 47 (04) : 844 - 851
  • [20] van der Geest RJ, 1999, J MAGN RESON IMAGING, V10, P602, DOI 10.1002/(SICI)1522-2586(199911)10:5<602::AID-JMRI3>3.0.CO