Wall Shear Stress Assessment of the False Lumen in Acute Type B Aortic Dissection Visualized by 4-Dimensional Flow Magnetic Resonance Imaging: An Ex-Vivo Study

被引:8
作者
Veger, Hugo T. C. [1 ]
Pasveer, Erik H. [1 ]
Westenberg, Jos J. M. [2 ]
Wever, Jan J. [1 ]
van Eps, Randolph G. Statius [1 ]
机构
[1] Haga Teaching Hosp, Dept Vasc Surg, Els Borst Eilerspl 275, NL-2545 AA The Hague, Netherlands
[2] Leiden Univ, Dept Radiol, Med Ctr, Leiden, Netherlands
关键词
aortic dissection; type B; four-dimensional flow magnetic resonance imaging; ex-vivo; THORACIC AORTA; TEAR SIZE; MANAGEMENT; QUANTIFICATION; PRESSURE; PORCINE; MOTION; MODEL;
D O I
10.1177/15385744211017117
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Four-dimensional flow magnetic resonance imaging (4D flow MRI) can accurately visualize and quantify flow and provide hemodynamic information such as wall shear stress (WSS). This imaging technique can be used to obtain more insight in the hemodynamic changes during cardiac cycle in the true and false lumen of uncomplicated acute Type B Aortic Dissection (TBAD). Gaining more insight of these forces in the false lumen in uncomplicated TBAD during optimal medical treatment, might result in prediction of adverse outcomes. Methods: A porcine aorta dissection model with an artificial dissection was positioned in a validated ex-vivo circulatory system with physiological pulsatile flow. 4D flow MR images with 3 set heartrates (HR; 60 bpm, 80 bpm and 100 bpm) were acquired. False lumen volume per cycle (FLV), mean and peak systolic WSS were determined from 4D flow MRI data. For validation, the experiment was repeated with a second porcine aorta dissection model. Results: During both experiments an increase in FLV (initial experiment: Delta FLV = 2.05 ml, p < 0.001, repeated experiment: Delta FLV = 1.08 ml, p = 0.005) and peak WSS (initial experiment: Delta WSS = 1.2 Pa, p = 0.004, repeated experiment: Delta WSS = 1.79 Pa, p = 0.016) was observed when HR increased from 60 to 80 bpm. Raising the HR from 80 to 100 bpm, no significant increase in FLV (p = 0.073, p = 0.139) was seen during both experiments. The false lumen mean WSS increased significant during initial (2.71 to 3.85 Pa; p = 0.013) and non-significant during repeated experiment (3.22 to 4.00 Pa; p = 0.320). Conclusion: 4D flow MRI provides insight into hemodynamic dimensions including WSS. Our ex-vivo experiments showed that an increase in HR from 60 to 80 bpm resulted in a significant increase of FLV and WSS of the false lumen. We suggest that strict heart rate control is of major importance to reduce the mean and peak WSS in uncomplicated acute TBAD. Because of the limitations of an ex-vivo study, 4D flow MRI will have to be performed in clinical setting to determine whether this imaging model would be of value to predict the course of uncomplicated TBAD.
引用
收藏
页码:696 / 701
页数:6
相关论文
共 25 条
  • [1] Pulsatile Flow Leads to Intimal Flap Motion and Flow Reversal in an In Vitro Model of Type B Aortic Dissection
    Birjiniuk, Joav
    Timmins, Lucas H.
    Young, Mark
    Leshnower, Bradley G.
    Oshinski, John N.
    Ku, David N.
    Veeraswamy, Ravi K.
    [J]. CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2017, 8 (03) : 378 - 389
  • [2] Aortic Customize: An In Vivo Feasibility Study of a Percutaneous Technique for the Repair of Aortic Aneurysms Using Injectable Elastomer
    Bosman, W. M. P. F.
    Vlot, J.
    van der Steenhoven, T. J.
    van den Berg, O.
    Hamming, J. F.
    de Vries, A. C.
    Brom, H. L. F.
    Jacobs, M. J.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2010, 40 (01) : 65 - 70
  • [3] True-lumen collapse in aortic dissection - Part II. Evaluation of treatment methods in phantoms with pulsatile flow
    Chung, JW
    Elkins, C
    Sakai, T
    Kato, N
    Vestring, T
    Semba, CP
    Slonim, SM
    Dake, MD
    [J]. RADIOLOGY, 2000, 214 (01) : 99 - 106
  • [4] A new imaging method for assessment of aortic dissection using four-dimensional phase contrast magnetic resonance imaging
    Clough, Rachel E.
    Waltham, Matthew
    Giese, Daniel
    Taylor, Peter R.
    Schaeffter, Tobias
    [J]. JOURNAL OF VASCULAR SURGERY, 2012, 55 (04) : 914 - 923
  • [5] Comparative Analysis of Porcine and Human Thoracic Aortic Stiffness
    de Beaufort, Hector W. L.
    Ferrara, Anna
    Conti, Michele
    Moll, Frans L.
    van Herwaarden, Joost A.
    Figueroa, C. Alberto
    Bismuth, Jean
    Auricchio, Ferdinando
    Trimarchi, Santi
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2018, 55 (04) : 560 - 566
  • [6] Four-dimensional, flow-sensitive magnetic resonance imaging of blood flow patterns in thoracic aortic dissections
    Francois, Christopher J.
    Markl, Michael
    Schiebler, Mark L.
    Niespodzany, Eric
    Landgraf, Benjamin R.
    Schlensak, Christian
    Frydrychowicz, Alex
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (05) : 1359 - 1366
  • [7] Aneurysm sac pressure monitoring: Does the direction of pressure measurement matter in fibrinous thrombus?
    Hinnen, Jan-Willem
    Rixen, Daniel J.
    Koning, Olivier H.
    Van Bockel, Hajo J.
    Hamming, Jaap F.
    [J]. JOURNAL OF VASCULAR SURGERY, 2007, 45 (04) : 812 - 816
  • [8] 2010 ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM Guidelines for the Diagnosis and Management of Patients With Thoracic Aortic Disease
    Hiratzka, Loren F.
    Bakris, George L.
    Beckman, Joshua A.
    Bersin, Robert M.
    Carr, Vincent F.
    Casey, Donald E., Jr.
    Eagle, Kim A.
    Hermann, Luke K.
    Isselbacher, Eric M.
    Kazerooni, Ella A.
    Kouchoukos, Nicholas T.
    Lytle, Bruce W.
    Milewicz, Dianna M.
    Reich, David L.
    Sen, Souvik
    Shinn, Julie A.
    Svensson, Lars G.
    Williams, David M.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (14) : E27 - E129
  • [9] Preliminary findings in quantification of changes in septal motion during follow-up of type B aortic dissections
    Karmonik, Christof
    Duran, Cassidy
    Shah, Dipan J.
    Anaya-Ayala, Javier E.
    Davies, Mark G.
    Lumsden, Alan B.
    Bismuth, Jean
    [J]. JOURNAL OF VASCULAR SURGERY, 2012, 55 (05) : 1419 - U598
  • [10] Wall shear stress: Theoretical considerations and methods of measurement
    Katritsis, Demosthenes
    Kaiktsis, Lambros
    Chaniotis, Andreas
    Pantos, John
    Efstathopoulos, Efstathios P.
    Marmarelis, Vasilios
    [J]. PROGRESS IN CARDIOVASCULAR DISEASES, 2007, 49 (05) : 307 - 329