Monte Carlo simulation of x-ray buildup factors of lead and its applications in shielding of diagnostic x-ray facilities

被引:14
作者
Kharrati, Hedi
Agrebi, Amel
Karaoui, Mohamed-Karim
机构
[1] Ecole Super Sci & Tech Sante Monastir, Monastir 5000, Tunisia
[2] Fac Sci Monastir, Monastir, Tunisia
关键词
X-ray; buildup factor; Monte Carlo simulation; lead barrier; broad beam transmission;
D O I
10.1118/1.2710333
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
X-ray buildup factors of lead in broad beam geometry for energies from 15 to 150 keV are determined using the general purpose Monte Carlo N-particle radiation transport computer code (MCNP4C). The obtained buildup factors data are fitted to a modified three parameter Archer et al. model for ease in calculating the broad beam transmission with computer at any tube potentials/filters combinations in diagnostic energies range. An example for their use to compute the broad beam transmission at 70, 100, 120, and 140 kVp is given. The calculated broad beam transmission is compared to data derived from literature, presenting good agreement. Therefore, the combination of the buildup factors data as determined and a mathematical model to generate x-ray spectra provide a computationally based solution to broad beam transmission for lead barriers in shielding x-ray facilities. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1398 / 1404
页数:7
相关论文
共 50 条
[31]   Voxel-based Monte Carlo simulation of X-ray imaging and spectroscopy experiments [J].
Bottigli, U ;
Brunetti, A ;
Golosio, B ;
Oliva, P ;
Stumbo, S ;
Vincze, L ;
Randaccio, P ;
Bleuet, P ;
Simionovici, A ;
Somogyi, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (10-11) :1747-1754
[32]   Monte Carlo simulation of an x-ray volume imaging cone beam CT unit [J].
Spezi, Emiliano ;
Downes, Patrick ;
Radu, Emil ;
Jarvis, Richard .
MEDICAL PHYSICS, 2009, 36 (01) :127-136
[33]   PENEPMA: A Monte Carlo Program for the Simulation of X-Ray Emission in Electron Probe Microanalysis [J].
Llovet, Xavier ;
Salvat, Francesc .
MICROSCOPY AND MICROANALYSIS, 2017, 23 (03) :634-646
[34]   Monte Carlo simulation applied in Total Reflection X-Ray Fluorescence: preliminary results [J].
Meira, Luiza L. C. ;
Inocente, Guilherme F. ;
Vieira, Leticia D. ;
Mesa, Joel .
XXXV BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 2013, 1529 :66-69
[35]   Monte-Carlo simulation of secondary electron emission by x-ray irradiation - an application of x-ray absorption near-edge structure (XANES) [J].
Iyasu, T ;
Tamura, K ;
Shimizu, R ;
Zhang, ZM ;
Koshikawa, T ;
Yoshikawa, H ;
Fukushima, S .
SURFACE AND INTERFACE ANALYSIS, 2004, 36 (10) :1413-1416
[36]   Monte Carlo simulation of x-ray generation and energy dissipation in a W/Cu target for optimum design of a high-power x-ray source [J].
Araki, K ;
Yoshioka, A ;
Shimizu, R ;
Nagatomi, T ;
Takahashi, S ;
Nihei, Y .
SURFACE AND INTERFACE ANALYSIS, 2002, 33 (05) :376-380
[37]   The Promising Use of Volcanic Silica as an Environmental Source for Diagnostic X-ray Shielding Applications [J].
Damoom, Mohammed M. .
CHALLENGES AND RECENT ADVANCEMENTS IN NUCLEAR ENERGY SYSTEMS, SCOPE 2023, 2024, :94-102
[38]   Monte Carlo simulation of the beta-ray induced X-ray spectra of tritium at various depths in solids [J].
Hara, Masanori ;
Shimura, Tomoya ;
Aoki, Kenjiro ;
Matsuyama, Masao ;
Aso, Tsukasa ;
Roellig, Marco .
FUSION ENGINEERING AND DESIGN, 2021, 172
[39]   X-Ray Inerferometer with a X-Ray Beamsplitter [J].
Kitamoto, S. ;
Sakata, K. ;
Murakami, H. ;
Yoshida, Y. ;
Seta, H. .
SPACE TELESCOPES AND INSTRUMENTATION 2012: ULTRAVIOLET TO GAMMA RAY, 2012, 8443
[40]   X-ray dosimetry: comparing Monte Carlo simulations and experimental data [J].
Stichelbaut, F ;
Bol, JL ;
Lundhal, B ;
Martin, F ;
Rose, G ;
Schlecht, J ;
Smith, R .
RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (1-2) :345-349