Monte Carlo simulation of x-ray buildup factors of lead and its applications in shielding of diagnostic x-ray facilities

被引:14
作者
Kharrati, Hedi
Agrebi, Amel
Karaoui, Mohamed-Karim
机构
[1] Ecole Super Sci & Tech Sante Monastir, Monastir 5000, Tunisia
[2] Fac Sci Monastir, Monastir, Tunisia
关键词
X-ray; buildup factor; Monte Carlo simulation; lead barrier; broad beam transmission;
D O I
10.1118/1.2710333
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
X-ray buildup factors of lead in broad beam geometry for energies from 15 to 150 keV are determined using the general purpose Monte Carlo N-particle radiation transport computer code (MCNP4C). The obtained buildup factors data are fitted to a modified three parameter Archer et al. model for ease in calculating the broad beam transmission with computer at any tube potentials/filters combinations in diagnostic energies range. An example for their use to compute the broad beam transmission at 70, 100, 120, and 140 kVp is given. The calculated broad beam transmission is compared to data derived from literature, presenting good agreement. Therefore, the combination of the buildup factors data as determined and a mathematical model to generate x-ray spectra provide a computationally based solution to broad beam transmission for lead barriers in shielding x-ray facilities. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1398 / 1404
页数:7
相关论文
共 50 条
[21]   New achievements in X-ray optics--the X-ray lens and its applications [J].
颜一鸣 ;
赫业军 ;
丁训良 ;
陈俊 ;
李玉德 ;
魏富忠 ;
谢晋东 ;
潘秋丽 ;
王大椿 .
ProgressinNaturalScience, 2001, (02) :9-15
[22]   Monte Carlo simulation of the imaging properties of scintillator-coated X-ray pixel detectors [J].
Hjelm, M ;
Norlin, B ;
Nilsson, HE ;
Fröjdh, C ;
Badel, X .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3) :76-85
[23]   Estimation of gamma- and X-ray photons buildup factor in soft tissue with Monte Carlo method [J].
Sardari, Dariush ;
Abbaspour, Ali ;
Baradaran, Samaneh ;
Babapour, Farshid .
APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) :1438-1440
[24]   Monte Carlo simulation of tritium beta-ray induced X-ray spectrum in various gases [J].
Hara, Masanori ;
Uchikawa, Ryota ;
Hatano, Yuji ;
Matsuyama, Masao ;
Aso, Tsukasa ;
Kawakami, Tomohiko ;
Ito, Takeshi .
FUSION ENGINEERING AND DESIGN, 2018, 131 :125-129
[25]   X-RAY COLLIMATOR DESIGN USING MONTE CARLO SIMULATIONS [J].
Han, Eun Young ;
Clarkson, Richard ;
Sharma, Sunil ;
Corry, Peter M. ;
Moros, Eduardo G. ;
Ratanatharathorn, Vaneerat .
BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2013, 25 (06)
[26]   Monte-Carlo simulation of a slot-scanning X-ray imaging system [J].
Kulkarni, Mayuresh ;
Dendere, Ronald ;
Nicolls, Fred ;
Steiner, Stef ;
Douglas, Tania S. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (01) :284-289
[27]   Method using a Monte Carlo simulation database for optimizing x-ray fluoroscopic conditions [J].
Ueki, H ;
Okajima, K .
MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 :524-535
[28]   X-ray spectra and quality parameters from Monte Carlo simulation and analytical filters [J].
Salehi, Z. ;
Ali, N. K. Ya ;
Yusoff, A. L. .
APPLIED RADIATION AND ISOTOPES, 2012, 70 (11) :2586-2589
[29]   X-ray imaging plate performance investigation based on a Monte Carlo simulation tool [J].
Yao, M. ;
Duvauchelle, Ph ;
Kaftandjian, V. ;
Peterzol-Parmentier, A. ;
Schumm, A. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 103 :84-91
[30]   A new Monte Carlo code for simulation of the effect of irregular surfaces on X-ray spectra [J].
Brunetti, Antonio ;
Golosio, Bruno .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 94-95 :58-62