Monte Carlo simulation of x-ray buildup factors of lead and its applications in shielding of diagnostic x-ray facilities

被引:14
作者
Kharrati, Hedi
Agrebi, Amel
Karaoui, Mohamed-Karim
机构
[1] Ecole Super Sci & Tech Sante Monastir, Monastir 5000, Tunisia
[2] Fac Sci Monastir, Monastir, Tunisia
关键词
X-ray; buildup factor; Monte Carlo simulation; lead barrier; broad beam transmission;
D O I
10.1118/1.2710333
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
X-ray buildup factors of lead in broad beam geometry for energies from 15 to 150 keV are determined using the general purpose Monte Carlo N-particle radiation transport computer code (MCNP4C). The obtained buildup factors data are fitted to a modified three parameter Archer et al. model for ease in calculating the broad beam transmission with computer at any tube potentials/filters combinations in diagnostic energies range. An example for their use to compute the broad beam transmission at 70, 100, 120, and 140 kVp is given. The calculated broad beam transmission is compared to data derived from literature, presenting good agreement. Therefore, the combination of the buildup factors data as determined and a mathematical model to generate x-ray spectra provide a computationally based solution to broad beam transmission for lead barriers in shielding x-ray facilities. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1398 / 1404
页数:7
相关论文
共 39 条
[1]   AN EVALUATION OF 2 AGGREGATES FOR USE IN A CONCRETE REACTOR SHIELD [J].
AHMED, FU ;
RAHMAN, MA ;
HUSAIN, SR ;
RAHMAN, MM .
NUCLEAR SCIENCE AND ENGINEERING, 1983, 85 (04) :427-430
[2]  
[Anonymous], ORNLRSIC10
[3]   DIAGNOSTIC-X-RAY SHIELDING DESIGN BASED ON AN EMPIRICAL-MODEL OF PHOTON ATTENUATION [J].
ARCHER, BR ;
THORNBY, JI ;
BUSHONG, SC .
HEALTH PHYSICS, 1983, 44 (05) :507-517
[4]   ATTENUATION PROPERTIES OF DIAGNOSTIC-X-RAY SHIELDING MATERIALS [J].
ARCHER, BR ;
FEWELL, TR ;
CONWAY, BJ ;
QUINN, PW .
MEDICAL PHYSICS, 1994, 21 (09) :1499-1507
[5]   Monte Carlo simulation of x-ray spectra in diagnostic radiology and mammography using MCNP4C [J].
Ay, MR ;
Shahriari, M ;
Sarkar, S ;
Adib, M ;
Zaidi, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (21) :4897-4917
[6]   Assessment of different computational models for generation of x-ray spectra in diagnostic radiology and mammography [J].
Ay, MR ;
Sarkar, S ;
Shahriari, M ;
Sardari, D ;
Zaidi, H .
MEDICAL PHYSICS, 2005, 32 (06) :1660-1675
[7]  
Berger M. J., 1987, 873597 NBSIR
[8]  
BERGER MJ, 1956, USNRDL REV LECT, V29, P7
[9]   Diagnostic x-ray spectra: A comparison of spectra generated by different computational methods with a measured spectrum [J].
Bhat, M ;
Pattison, J ;
Bibbo, G ;
Caon, M .
MEDICAL PHYSICS, 1998, 25 (01) :114-120
[10]   COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR [J].
BIRCH, R ;