Remote Sensing of Heartbeat based on Space Diversity Using MIMO FMCW Radar

被引:1
作者
Yamamoto, Kohei [1 ]
Endo, Koji [1 ]
Ohtsuki, Tomoaki [2 ]
机构
[1] Keio Univ, Grad Sch Sci & Technol, Yokohama, Kanagawa 2238522, Japan
[2] Keio Univ, Dept Informat & Comp Sci, Yokohama, Kanagawa 2238522, Japan
来源
2021 IEEE GLOBAL COMMUNICATIONS CONFERENCE (GLOBECOM) | 2021年
关键词
DISEASE;
D O I
10.1109/GLOBECOM46510.2021.9685033
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Remote sensing of heartbeat offers various applications in the medical and health care fields. To realize non-contact heartbeat detection, an FMCW (Frequency Modulated Continuous Wave) radar-based heartbeat detection method has been investigated. The conventional FMCW radar-based heartbeat detection method estimates a range from an FMCW radar to a subject and extracts heartbeat components from phase changes for the range. However, the range suitable for extracting heartbeat components can change over time due to respiration and body fluctuation. Thus, when the SNR (Signal-to-Noise Ratio) of heartbeat components over phase changes is low at the estimated range, the accuracy of heartbeat detection tends to degrade. In this paper, we propose a MIMO (Multiple-Input Multiple-Output) FMCW radar-based heartbeat detection method based on space diversity. A MIMO FMCW radar can estimate the range for multiple beam directions and obtain phase changes for a space specified with the range and the beam direction. The SNR of heartbeat components over phase changes differs from one space to another. Taking it into account, the proposed method detects heartbeat by exploiting the space diversity of phase changes. The experimental results showed that compared to the detection method using only one phase change, the proposed method using phase changes for multiple spaces detected heartbeat accurately, which is brought by the diversity effect of phase changes for multiple spaces.
引用
收藏
页数:6
相关论文
共 19 条
  • [1] Remote Monitoring of Human Vital Signs Using mm-Wave FMCW Radar
    Alizadeh, Mostafa
    Shaker, George
    Martins De Almeida, Joao Carlos
    Morita, Plinio Pelegrini
    Safavi-Naeini, Safeddin
    [J]. IEEE ACCESS, 2019, 7 : 54958 - 54968
  • [2] Alizadeh SM, 2018, 2018 25TH IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING AND 2018 3RD INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING (ICBME), P1
  • [3] Improved Contactless Heartbeat Estimation in FMCW Radar via Kalman Filter Tracking
    Arsalan, Muhammad
    Santra, Avik
    Will, Christoph
    [J]. IEEE SENSORS LETTERS, 2020, 4 (05)
  • [4] Brindle JT, 2002, NAT MED, V8, P1439, DOI 10.1038/nm802
  • [5] Continuous Human Motion Recognition With a Dynamic Range-Doppler Trajectory Method Based on FMCW Radar
    Ding, Chuanwei
    Hong, Hong
    Zou, Yu
    Chu, Hui
    Zhu, Xiaohua
    Fioranelli, Francesco
    Le Kernec, Julien
    Li, Changzhi
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2019, 57 (09): : 6821 - 6831
  • [6] Simultaneous Detection of Multi-Target Vital Signs Using EEMD Algorithm Based on FMCW Radar
    Fang, Guan-Wei
    Huang, Ching-Yao
    Yang, Chin-Lung
    [J]. 2019 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE (IMBIOC 2019), 2019,
  • [7] Novel signal processing method for vital sign monitoring using FMCW radar
    He, Mi
    Nian, Yongjian
    Gong, Yushun
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2017, 33 : 335 - 345
  • [8] Inclusion of Respiratory Frequency Information in Heart Rate Variability Analysis for Stress Assessment
    Hernando, Alberto
    Lazaro, Jesus
    Gil, Eduardo
    Arza, Adriana
    Mario Garzon, Jorge
    Lopez-Anton, Raul
    de la Camara, Concepcion
    Laguna, Pablo
    Aguilo, Jordi
    Bailon, Raquel
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2016, 20 (04) : 1016 - 1025
  • [9] Islam SMM, 2020, IEEE MTT S INT MICR, P783, DOI 10.1109/IMS30576.2020.9223838
  • [10] Low-Complexity Joint Extrapolation-MUSIC-Based 2-D Parameter Estimator for Vital FMCW Radar
    Kim, Sangdong
    Lee, Kyun-Kyung