Validation of a novel automated border-detection algorithm for rapid and accurate quantitation of left ventricular volumes based on three-dimensional echocardiography

被引:100
|
作者
Muraru, Denisa [1 ]
Badano, Luigi P. [2 ]
Piccoli, Gianluca [3 ]
Gianfagna, Pasquale [2 ]
Del Mestre, Lorenzo [2 ]
Ermacora, Davide [2 ]
Proclemer, Alessandro [2 ]
机构
[1] Prof Dr CC Iliescu Inst Cardiovasc Dis, Bucharest 022322, Romania
[2] Univ Hosp Santa Maria della Misericordia, Dept Cardiopulm Sci, Udine, Italy
[3] Univ Hosp Santa Maria della Misericordia, Dept Radiol, Udine, Italy
来源
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY | 2010年 / 11卷 / 04期
关键词
Three-dimensional echocardiography; Cardiac magnetic resonance; Left ventricular volumes; Left ventricular function; Left ventricle; Automated border detection; CARDIAC MAGNETIC-RESONANCE; EJECTION FRACTION; SEMIAUTOMATED QUANTIFICATION; AMERICAN-SOCIETY; REPRODUCIBILITY; PARAMETERS; SIZE;
D O I
10.1093/ejechocard/jep217
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To assess the accuracy and reproducibility of a novel automated software for left ventricular (LV) volumes and ejection fraction (EF) measurements using real-time three-dimensional echocardiography (3DE). A total of 103 patients with a wide range of LV volumes were analyzed with both 4D AutoLVQ (TM) and 4D TomTec (TM) software. In 23 patients, a side-by-side comparison of LV volume and EF measurements was done between 3DE, 2DE, and cardiac magnetic resonance (CMR). Excellent correlation was found between 4D AutoLVQ and 4D TomTec [r = 0.98 for end-diastolic volume (EDV), 0.99 for end-systolic volume (ESV), and 0.97 for EF, P < 0.0001], with small biases and narrow limits of agreement: EDV 5.2 mL (-14 to 25 mL), ESV 2.9 mL (-10 to 16 mL), EF -0.2% (-7 to 6%). Time of analysis was halved using 4D AutoLVQ with manual correction (1 min 52 s +/- 30 s) in comparison with 4D TomTec software (3 min 46 s +/- 1 min 24 s). Both softwares showed similar accuracy in comparison with CMR (4D AutoLVQ biases -11.0 mL, -9.1 mL, and 2.9%; 4D TomTec biases -8.3 mL, -7.4 mL, and 2.8% for EDV, ESV, and EF, respectively, P = NS for all) and good reproducibility. Novel 4D AutoLVQ software showed very good agreement with more time-consuming 4D TomTec software, having similar accuracy against CMR.
引用
收藏
页码:359 / 368
页数:10
相关论文
共 50 条
  • [31] Accurate measurement of left ventricular mass by three-dimensional echocardiography with unrestricted plane positioning
    Chuang, ML
    Beaudin, RA
    Riley, MF
    Manning, WJ
    Feamside, JT
    Douglas, PS
    Hibberd, MG
    CIRCULATION, 1996, 94 (08) : 4023 - 4023
  • [32] Assessment of resynchronisation therapy based on dynamic three-dimensional echocardiography and semi-automated border detection
    Szili-Torok, T
    Krenning, BJ
    Voormolen, MM
    Theuns, DAMJ
    Jordaens, LJ
    Ten Cate, F
    Roelandt, JRTC
    EUROPEAN HEART JOURNAL, 2003, 24 : 395 - 395
  • [33] The use of real-time three-dimensional echocardiography for the quantification of left ventricular volumes and function
    Mor-Avi, Victor
    Lang, Roberto M.
    CURRENT OPINION IN CARDIOLOGY, 2009, 24 (05) : 402 - 409
  • [34] Partition values for normal left and right ventricular volumes and ejection fraction by three-dimensional echocardiography
    Gopal, AS
    Krishnaswamy, R
    Toole, R
    Schapiro, W
    Reichek, N
    EUROPEAN HEART JOURNAL, 2004, 25 : 341 - 341
  • [35] Sources of variation and bias in assessing left ventricular volumes and dyssynchrony using three-dimensional echocardiography
    Muraru, Denisa
    Badano, Luigi P.
    Ermacora, Davide
    Piccoli, Gianluca
    Iliceto, Sabino
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (06): : 1357 - 1368
  • [36] Sources of variation and bias in assessing left ventricular volumes and dyssynchrony using three-dimensional echocardiography
    Denisa Muraru
    Luigi P. Badano
    Davide Ermacora
    Gianluca Piccoli
    Sabino Iliceto
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1357 - 1368
  • [37] Reliability of left ventricular volumes and function measurements using three-dimensional speckle tracking echocardiography
    Kleijn, Sebastiaan A.
    Aly, Mohamed F. A.
    Terwee, Caroline B.
    van Rossum, Albert C.
    Kamp, Otto
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (02) : 159 - 168
  • [38] Three-Dimensional Echocardiography Derived Nomograms for Left Ventricular Volumes in Healthy Caucasian Italian Children
    Cantinotti, Massimiliano
    Scalese, Marco
    Giordano, Raffaele
    Franchi, Eliana
    Marchese, Pietro
    Assanta, Nadia
    Molinaro, Sabrina
    Paterni, Marco
    Iervasi, Giorgio
    Koestenberger, Martin
    Kutty, Shelby
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2019, 32 (06) : 794 - +
  • [39] Clinical validation of automated computer analysis of left ventricular functions using real-time three-dimensional echocardiography
    Song, JM
    Qin, JX
    Agler, DA
    Greenberg, NL
    Oryszak, S
    Thomas, JD
    Shiota, T
    CIRCULATION, 2004, 110 (17) : 569 - 569
  • [40] Unbiased and efficient estimation of left ventricular volumes by three-dimensional echocardiography with coaxial sections. Validation with magnetic resonance imaging
    W. Y. Kim
    Kim A. Terp
    Jens R. Nyengaard
    Trine Silkjær
    F. Taagehøj Jensen
    Heart and Vessels, 2000, 15 : 35 - 43