Validation of a novel automated border-detection algorithm for rapid and accurate quantitation of left ventricular volumes based on three-dimensional echocardiography

被引:100
|
作者
Muraru, Denisa [1 ]
Badano, Luigi P. [2 ]
Piccoli, Gianluca [3 ]
Gianfagna, Pasquale [2 ]
Del Mestre, Lorenzo [2 ]
Ermacora, Davide [2 ]
Proclemer, Alessandro [2 ]
机构
[1] Prof Dr CC Iliescu Inst Cardiovasc Dis, Bucharest 022322, Romania
[2] Univ Hosp Santa Maria della Misericordia, Dept Cardiopulm Sci, Udine, Italy
[3] Univ Hosp Santa Maria della Misericordia, Dept Radiol, Udine, Italy
来源
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY | 2010年 / 11卷 / 04期
关键词
Three-dimensional echocardiography; Cardiac magnetic resonance; Left ventricular volumes; Left ventricular function; Left ventricle; Automated border detection; CARDIAC MAGNETIC-RESONANCE; EJECTION FRACTION; SEMIAUTOMATED QUANTIFICATION; AMERICAN-SOCIETY; REPRODUCIBILITY; PARAMETERS; SIZE;
D O I
10.1093/ejechocard/jep217
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To assess the accuracy and reproducibility of a novel automated software for left ventricular (LV) volumes and ejection fraction (EF) measurements using real-time three-dimensional echocardiography (3DE). A total of 103 patients with a wide range of LV volumes were analyzed with both 4D AutoLVQ (TM) and 4D TomTec (TM) software. In 23 patients, a side-by-side comparison of LV volume and EF measurements was done between 3DE, 2DE, and cardiac magnetic resonance (CMR). Excellent correlation was found between 4D AutoLVQ and 4D TomTec [r = 0.98 for end-diastolic volume (EDV), 0.99 for end-systolic volume (ESV), and 0.97 for EF, P < 0.0001], with small biases and narrow limits of agreement: EDV 5.2 mL (-14 to 25 mL), ESV 2.9 mL (-10 to 16 mL), EF -0.2% (-7 to 6%). Time of analysis was halved using 4D AutoLVQ with manual correction (1 min 52 s +/- 30 s) in comparison with 4D TomTec software (3 min 46 s +/- 1 min 24 s). Both softwares showed similar accuracy in comparison with CMR (4D AutoLVQ biases -11.0 mL, -9.1 mL, and 2.9%; 4D TomTec biases -8.3 mL, -7.4 mL, and 2.8% for EDV, ESV, and EF, respectively, P = NS for all) and good reproducibility. Novel 4D AutoLVQ software showed very good agreement with more time-consuming 4D TomTec software, having similar accuracy against CMR.
引用
收藏
页码:359 / 368
页数:10
相关论文
共 50 条
  • [1] Rapid three-dimensional echocardiography - Clinically feasible alternative for precise and accurate measurement of left ventricular volumes
    Belohlavek, M
    Tanabe, K
    Jakrapanichakul, D
    Breen, JF
    Seward, JB
    CIRCULATION, 2001, 103 (24) : 2882 - 2884
  • [2] Validation of live three-dimensional echocardiography for quantification of absolute left ventricular volumes; comparison with volumetric three-dimensional echocardiography
    Shin, JH
    Shiota, T
    Qin, JX
    Agler, DA
    Saracino, G
    Greenberg, N
    Oryszak, S
    Thomas, JD
    EUROPEAN HEART JOURNAL, 2004, 25 : 260 - 260
  • [3] Rapid and accurate left ventricular surface generation from three-dimensional echocardiography by a catalog based method
    Selwyn P. Wong
    Richard K. Johnson
    Florence H. Sheehan
    The International Journal of Cardiovascular Imaging, 2003, 19 : 9 - 17
  • [4] Validation of novel vendor-independent software algorithm for left ventricular volumes and ejection fraction by three-dimensional echocardiography: impact of manual correction versus automated tracking
    Cecchetto, A.
    Muraru, D.
    Spadotto, V.
    Romeo, G.
    Aruta, P.
    Mihaila, S.
    Onciul, S.
    Cucchini, U.
    Iliceto, S.
    Badano, P.
    EUROPEAN HEART JOURNAL, 2015, 36 : 426 - 426
  • [5] Automated Three-Dimensional Left Ventricular Volumes: Rise of the Machines?
    Nedadur, Rashmi
    Tsang, Wendy
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2019, 32 (09) : 1116 - 1119
  • [6] Automated border detection in three-dimensional echocardiography: principles and promises
    Leung, K. Y. Esther
    Bosch, Johan G.
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2010, 11 (02): : 97 - 108
  • [7] Rapid and accurate left ventricular surface generation from three-dimensional echocardiography by a catalog based method - Rapid LV surface generation by three-dimensional echo
    Wong, SP
    Johnson, RK
    Sheehan, FH
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2003, 19 (01): : 9 - 17
  • [8] Rapid image acquisition and automated determination of left ventricular cavity boundary for precise and accurate volumetry by clinical three-dimensional echocardiography
    Belohlavek, M
    Seward, JB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 7054 - 7054
  • [9] Rapid freehand scanning three-dimensional echocardiography: Accurate measurement of left ventricular volumes and ejection fraction compared with quantitative gated scintigraphy
    Kawai, J
    Tanabe, K
    Morioka, S
    Shiotani, H
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2003, 16 (02) : 110 - 115
  • [10] Real-time three-dimensional echocardiography for measurement of left ventricular volumes
    Schmidt, MA
    Ohazama, CJ
    Agyeman, KO
    Freidlin, RZ
    Jones, M
    Laurienzo, JM
    Brenneman, CL
    Arai, AE
    von Ramm, OT
    Panza, JA
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (12): : 1434 - 1439