Measurement of mass attenuation coefficients of some boron compounds and the trommel sieve waste in the energy range 15.746-40.930 keV

被引:25
作者
Içelli, O [1 ]
Erzeneoglu, S
Boncukçuoglu, R
机构
[1] Ataturk Univ, Educ Fac Erzincan, Dept Educ Phys, Erzincan, Turkey
[2] Ataturk Univ, Fac Sci, Dept Phys, Erzurum, Turkey
[3] Ataturk Univ, Fac Engn, Dept Environm Engn, Erzurum, Turkey
关键词
D O I
10.1016/S0022-4073(02)00210-8
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Mass attenuation coefficients of some boron compounds (H3BO3, Na2B4O7 and B3Al2O3) and the trommel sieve waste (TSW) have been measured by using an extremely narrow collimated-beam transmission method in the energy range 15.746-40.930 keV. The characteristic Kalpha and Kbeta X-rays of Zr, Mo, Ag, In, Sb, Ba and Pr passed through H3BO3, Na2B4O7, B3Al2O3 and TSW were detected with a high-resolution Si(Li) detector. The measured values are compared with the theoretical ones obtained using the WINXCOM. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:203 / 210
页数:8
相关论文
共 25 条
[11]  
2-N
[12]   Radioisotope X-ray fluorescence analysis of some elements in colemanite ore [J].
Karabulut, A ;
Budak, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (01) :91-95
[13]   ANOMALOUS X-RAY ATTENUATION COEFFICIENTS AROUND THE ABSORPTION EDGES USING MN K-ALPHA AND CU K-ALPHA X-RAYS [J].
KERUR, BR ;
THONTADARYA, SR ;
HANUMAIAH, B .
APPLIED RADIATION AND ISOTOPES, 1994, 45 (02) :159-163
[14]   Gamma-ray attenuation coefficients in some heavy metal oxide borate glasses at 662keV [J].
Khanna, A ;
Bhatti, SS ;
Singh, KJ ;
Thind, KS .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1996, 114 (3-4) :217-220
[15]   DISSOLUTION KINETICS OF COLEMANITE IN SO2-SATURATED WATER [J].
KOCAKERIM, MM ;
ALKAN, M .
HYDROMETALLURGY, 1988, 19 (03) :385-392
[16]  
Muramatsu Y, 1999, X-RAY SPECTROM, V28, P503, DOI 10.1002/(SICI)1097-4539(199911/12)28:6<503::AID-XRS385>3.0.CO
[17]  
2-F
[18]   Flow injection spectrophotometric determination of boron in ceramic materials [J].
Sanchez-Ramos, S ;
Medina-Hernandez, MJ ;
Sagrado, S .
TALANTA, 1998, 45 (05) :835-842
[19]   Validation of a method for the determination of boron in ceramic materials by X-ray fluorescence spectrometry [J].
Sánchez-Ramos, S ;
Bosch-Reig, F ;
Gimeno-Adelantado, JV ;
Yusá-Marco, DJ ;
Doménech-Carbó, A ;
Berja-Pérez, JA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (11) :1669-1677
[20]  
Sciler H.G., 1998, HDB TOXICITY INORGAN