Measurement of mass attenuation coefficients of some boron compounds and the trommel sieve waste in the energy range 15.746-40.930 keV

被引:25
作者
Içelli, O [1 ]
Erzeneoglu, S
Boncukçuoglu, R
机构
[1] Ataturk Univ, Educ Fac Erzincan, Dept Educ Phys, Erzincan, Turkey
[2] Ataturk Univ, Fac Sci, Dept Phys, Erzurum, Turkey
[3] Ataturk Univ, Fac Engn, Dept Environm Engn, Erzurum, Turkey
关键词
D O I
10.1016/S0022-4073(02)00210-8
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Mass attenuation coefficients of some boron compounds (H3BO3, Na2B4O7 and B3Al2O3) and the trommel sieve waste (TSW) have been measured by using an extremely narrow collimated-beam transmission method in the energy range 15.746-40.930 keV. The characteristic Kalpha and Kbeta X-rays of Zr, Mo, Ag, In, Sb, Ba and Pr passed through H3BO3, Na2B4O7, B3Al2O3 and TSW were detected with a high-resolution Si(Li) detector. The measured values are compared with the theoretical ones obtained using the WINXCOM. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:203 / 210
页数:8
相关论文
共 25 条
[1]  
Agarwal BK., 1991, XRAY SPECTROSCOPY
[2]  
ALKAN M, 1985, J CHEM TECH BIOT A, V35, P382
[3]   Measurement of mass attenuation coefficients for four mixtures using X-rays from 13 keV up to 40 keV [J].
Angelone, M ;
Esposito, A ;
Chiti, M ;
Gentile, A .
RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) :547-548
[4]   Application of boron isotopes for tracing sources of anthropogenic contamination in groundwater [J].
Barth, S .
WATER RESEARCH, 1998, 32 (03) :685-690
[5]   Utilization of trommel sieve waste as an additive in Portland cement production [J].
Boncukcuoglu, R ;
Yilmaz, MT ;
Kocakerim, MM ;
Tosunoglu, V .
CEMENT AND CONCRETE RESEARCH, 2002, 32 (01) :35-39
[6]   Borax production from borax slime, an industrial waste [J].
Boncukcuoglu, R ;
Kocakkerim, MM ;
Alkan, M .
WATER AIR AND SOIL POLLUTION, 1998, 104 (1-2) :103-112
[7]   Upgrading of the reactor waste obtained during borax production from tincal [J].
Boncukcuoglu, R ;
Kocakerim, MM ;
Ersahan, H .
MINERALS ENGINEERING, 1999, 12 (10) :1275-1280
[8]   The measurement of thermal neutron flux depression for determining the concentration of boron in blood [J].
Brooke, SL ;
Green, S ;
Charles, MW ;
Beddoe, AH .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (03) :707-715
[9]   X-ray absorption in matter. reengineering XCOM [J].
Gerward, L ;
Guilbert, N ;
Jensen, KB ;
Levring, H .
RADIATION PHYSICS AND CHEMISTRY, 2001, 60 (1-2) :23-24
[10]  
Kaneyoshi T, 1999, X-RAY SPECTROM, V28, P497, DOI 10.1002/(SICI)1097-4539(199911/12)28:6<497::AID-XRS379>3.0.CO