Rifampicin determination in plasma by stir bar-sorptive extraction and liquid chromatography

被引:35
作者
Balbao, Marina Salviato [1 ]
Bertucci, Carlo [2 ]
Bergamaschi, Mateus Machado [1 ]
Costa Queiroz, Regina Helena [1 ]
Malfara, Wilson Roberto [1 ]
Carvalho Dreossi, Sonia Aparecida [1 ]
Mello, Lidervan de Paula [3 ]
Costa Queiroz, Maria Eugenia [3 ]
机构
[1] Univ Sao Paulo, Fac Ciencias Farmaceut Ribeirao Preto, Dept Anal Clin Toxicol & Bromatol, BR-14040903 Sao Paulo, Brazil
[2] Univ Bologna, Dept Pharmaceut Sci, I-40126 Bologna, Italy
[3] Univ Sao Paulo, Fac Filosofia Ciencias & Letras Ribeirao Preto, Dept Quim, BR-14040903 Sao Paulo, Brazil
关键词
Stir bar-sorptive extraction; High performance liquid chromatography; Rifampicin; Therapeutic drug monitoring; Drug stability; THERMAL-DESORPTION; MASS SPECTROMETRY; UV DETECTION; HPLC METHOD; PYRAZINAMIDE; URINE; QUANTIFICATION; 4-NONYLPHENOL; MATRICES; SAMPLES;
D O I
10.1016/j.jpba.2009.11.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and reproducible stir bar-sorptive extraction and high performance liquid chromatography-UV detection (SBSE/HPLC-UV) method for therapeutic drug monitoring of rifampicin in plasma samples is described and compared with a liquid:liquid extraction (LLE/HPLC-UV) method. This miniaturized method can result in faster analysis, higher sample throughput, lower solvent consumption and less workload per sample while maintaining or even improving sensitivity. Important factors in the optimization of SBSE efficiency such as pH, temperature, extraction time and desorption conditions (solvents, mode magnetic stir, mode ultrasonic stir, time and number of steps) were optimized recoveries ranging from 75 to 80%. Separation was obtained using a reverse phase C-8 column with UV detection (254 nm). The mobile phase consisted of methanol:0.25 N sodium acetate buffer, pH 5.0 (58:42, v/v). The SBSE/HPLC-UV method was linear over a working range of 0.125-50.0 mu g mL(-1). The intra-assay and inter-assay precision and accuracy were studied at three concentrations (1.25, 6.25 and 25.0 mu g mL(-1)). The intra-assay coefficients of variation (CVs) for all compounds were less than 10% and all inter-CVs were less than 10%. Limits of quantification were 0.125 mu g mL(-1). Stability studies showed rifampicin was stable in plasma for 12 h after thawing; the samples were also stable for 24 h after preparation. Based on the figures of merit results, the SBSE/HPLC-UV proved to be adequate to the rifampicin analyses from therapeutic to toxic levels. This method was successfully applied to the analysis of real samples and was as effective as the LLE/HPLC-UV method. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1078 / 1083
页数:6
相关论文
共 30 条
  • [1] Determination of rifampicin in human plasma and blood spots by high performance liquid chromatography with UV detection: A potential method for therapeutic drug monitoring
    Allanson, A. L.
    Cotton, M. M.
    Tettey, J. N. A.
    Boyter, A. C.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (04) : 963 - 969
  • [2] Determination of steroid sex hormones in water and urine matrices by stir bar sorptive extraction and liquid chromatography with diode array detection
    Almeida, C.
    Nogueira, J. M. F.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (04) : 1303 - 1311
  • [3] Simultaneous determination of rifampicin and sulbactam in mouse plasma by high-performance liquid chromatography
    Aparicio, Irene
    Bello, Miguel Angel
    Callejon, Manuel
    Guiraum, Alfonso
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (08) : 748 - 752
  • [4] Simultaneous Quantification of Linezolid, Rifampicin, Levofloxacin, and Moxifloxacin in Human Plasma Using High-Performance Liquid Chromatography With UV
    Baietto, Lorena
    D'Avolio, Antonio
    De Rosa, Francesco Giuseppe
    Garazzino, Silvia
    Patanella, Samantha
    Siccardi, Marco
    Sciandra, Matiro
    Di Perri, Giovanni
    [J]. THERAPEUTIC DRUG MONITORING, 2009, 31 (01) : 104 - 109
  • [5] High-performance liquid-chromatographic determination of rifampicin in plasma and tissues
    Calleja, I
    Blanco-Príeto, MJ
    Ruz, N
    Renedo, MJ
    Dios-Viéitez, MC
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1031 (1-2) : 289 - 294
  • [6] Validation of a RP-LC method for the simultaneous determination of isoniazid, pyrazinamide and rifampicin in a pharmaceutical formulation
    Calleri, E
    De Lorenzi, E
    Furlanetto, S
    Massolini, G
    Caccialanza, G
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 29 (06) : 1089 - 1096
  • [7] Stir bar sorptive extraction and liquid chromatography with UV detection for determination of antidepressants in plasma samples
    Chaves, Andrea Rodrigues
    Silva, Silvana Maciel
    Costa Queiroz, Regina Helena
    Lancas, Fernando Mauro
    Costa Queiroz, Maria Eugnia
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 850 (1-2): : 295 - 302
  • [8] Quantification of carbamazepine, carbamazepine-10,11-epoxide, phenytoin and phenobarbital in plasma samples by stir bar-sorptive extraction and liquid chromatography
    Costa Queiroz, Regina Helena
    Bertucci, Carlo
    Malfara, Wilson Roberto
    Carvalho Dreossi, Sonia Aparecida
    Chaves, Andrea Rodrigues
    Rodrigues Valerio, Daniel Augusto
    Costa Queiroz, Maria Eugenia
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (02) : 428 - 434
  • [9] Stir bar sorptive extraction for trace analysis
    David, Frank
    Sandra, Pat
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1152 (1-2) : 54 - 69
  • [10] Determination of fluoxetine in plasma by gas chromatography-mass spectrometry using stir bar sorptive extraction
    Fernandes, Christian
    Van Hoeck, Els
    Sandra, Pat
    Lancas, Fernando M.
    [J]. ANALYTICA CHIMICA ACTA, 2008, 614 (02) : 201 - 207