A prospective ultrasound biomicroscopy evaluation of changes in anterior segment morphology after laser iridotomy in Asian eyes

被引:141
作者
Gazzard, G
Friedman, DS
Devereux, JG
Chew, P
Seah, SKL
机构
[1] Singapore Natl Eye Ctr, Singapore 168751, Singapore
[2] Inst Ophthalmol, London, England
[3] Moorfields Eye Hosp, Glaucoma Res Unit, London, England
[4] Singapopre Eye Res Inst, Singapore, Singapore
[5] Johns Hopkins Univ, Wilmer Ophthalmol Inst, Baltimore, MD 21218 USA
[6] Natl Univ Singapore, Singapore 117548, Singapore
关键词
D O I
10.1016/S0161-6420(02)01893-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To prospectively quantify changes in anterior segment morphology after laser iridotomy using gonioscopy and ultrasound biomicroscopy (UBM). Design: Prospective comparative observational case series. Participants: Fifty-five fellow eyes of patients presenting with acute primary angle closure (APAC). Methods: The fellow eyes of patients presenting with APAC were examined with UBM, A-scan ultrasonography, and optical pachymetry at presentation and 2 weeks after sequential argon/neodymium yttrium-aluminum-garnet laser peripheral iridotomy (LPI). UBM images were analyzed using UBM Pro 2000 software. Baseline measurements were made both under standard lighting conditions and in darkness to look for changes in anterior segment findings. Main Outcome Measures: The degree of angle opening was measured using the angle-opening distance (AOD) at 250 and 500 mum from the scleral spur (AOD250 and AOD500, respectively) and angle recess area (ARA). Results: Fifty-five Asian patients were examined; AOD250, AOD500, and ARA all significantly increased after sequential laser iridotomy (P < 0.002). Gonioscopic grading of the angle opening significantly increased in all 4 quadrants (P < 0.001). The Van Herick grade of limbal anterior chamber depth increased (P < 0.001), whereas the number of eyes classified as occludable decreased (73%-33%, P < 0.001). Anterior chamber depth did not change significantly (2.41 mm +/- 0.28 mm vs. 2.42 mm +/- 0.30 mm, P = 0.43) as measured with optical pachymetry. Increased illumination increased the angle-opening measures, but induced a different alteration in peripheral iris morphology. Illumination-induced changes were greater after iridotomy than before laser treatment. Conclusions: In Asian eyes at high risk of developing APAC, sequential LPI produced a significant widening of the anterior chamber angle without deepening the anterior chamber centrally. LPI produces changes in iris morphology that are different from those caused by an increase in illumination, indicating that different mechanisms account for angle opening under these 2 conditions.
引用
收藏
页码:630 / 638
页数:9
相关论文
共 43 条
  • [1] [Anonymous], 1994, OPHTHALMOLOGY, V101, P1749
  • [2] Acute primary angle-closure: Long-term intraocular pressure outcome in Asian eyes
    Aung, T
    Ang, LP
    Chan, SP
    Chew, PTK
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2001, 131 (01) : 7 - 12
  • [3] Increase in iris-lens contact after laser iridotomy for pupillary block angle closure
    Caronia, RM
    Liebmann, JM
    Stegman, Z
    Sokol, J
    Ritch, R
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1996, 122 (01) : 53 - 57
  • [4] GENES, PEOPLES AND LANGUAGES
    CAVALLISFORZA, LL
    [J]. SCIENTIFIC AMERICAN, 1991, 265 (05) : 72 - 78
  • [5] Biometry and primary angle-closure glaucoma among Chinese, white, and black populations
    Congdon, NG
    Qi, YL
    Quigley, H
    Hung, PT
    Wang, TH
    Ho, TC
    Tielsch, JM
    [J]. OPHTHALMOLOGY, 1997, 104 (09) : 1489 - 1495
  • [6] Angle-closure glaucoma in an urban population in southern India - The Andhra Pradesh Eye Disease Study
    Dandona, L
    Dandona, R
    Mandal, P
    Srinivas, M
    John, RK
    McCarty, CA
    Rao, GN
    [J]. OPHTHALMOLOGY, 2000, 107 (09) : 1710 - 1716
  • [7] BEHAVIOR OF THE FELLOW EYE IN ACUTE ANGLE-CLOSURE GLAUCOMA
    EDWARDS, RS
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1982, 66 (09) : 576 - 579
  • [8] The incidence of primary angle-closure glaucoma in Olmsted County, Minnesota
    Erie, JC
    Hodge, DO
    Gray, DT
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (02) : 177 - 181
  • [9] FLECK B W, 1991, Eye (London), V5, P315
  • [10] Anterior chamber depth in Mongolians: Variation with age, sex, and method of measurement
    Foster, PJ
    Alsbirk, PH
    Baasanhu, J
    Munkhbayar, D
    Uranchimeg, D
    Johnson, GJ
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 124 (01) : 53 - 60