Near optimal energy selective x-ray imaging system performance with simple detectors

被引:33
作者
Alvarez, Robert E. [1 ]
机构
[1] Aprend Technol, Mountain View, CA 94043 USA
关键词
biomedical imaging; X-ray imaging; X-ray tubes; SINOGRAM DATA; NOISE;
D O I
10.1118/1.3284538
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Methods: A performance measure is derived by applying statistical detection theory to an abstract vector space of the line integrals of the basis set coefficients of the two function approximation to the x-ray attenuation coefficient. The approach produces optimal results that utilize all the available energy dependent data. The method can be used with any energy selective detector and is applied not only to detectors using pulse height analysis (PHA) but also to a detector that simultaneously measures the total photon number and integrated energy, as discussed by Roessl [Med. Phys. 34, 959-966 (2007)]. A generalization of this detector that improves the performance is introduced. A method is described to compute images with the optimal SNR using projections in a "whitened" vector space transformed so the noise is uncorrelated and has unit variance in both coordinates. Material canceled images with optimal SNR can also be computed by projections in this space. Results: The performance measure is validated by showing that it provides the Tapiovaara-Wagner optimal results for a detector with full energy information and also a conventional detector. The performance with different types of detectors is compared to the ideal SNR as a function of x-ray tube voltage and subject thickness. A detector that combines two bin PHA with a simultaneous measurement of integrated photon energy provides near ideal performance across a wide range of operating conditions. Conclusions: Low energy resolution detectors can be used in energy selective x-ray imaging systems to produce images with near optimal performance.
引用
收藏
页码:822 / 841
页数:20
相关论文
共 32 条
[1]   COMPARISON OF NOISE AND DOSE IN CONVENTIONAL AND ENERGY SELECTIVE COMPUTED-TOMOGRAPHY [J].
ALVAREZ, R ;
SEPPI, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) :2853-2855
[2]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[3]  
ALVAREZ RE, 1976, THESIS STANFORD U
[4]  
[Anonymous], 1993, FUNDAMENTALS STAT PR
[5]  
[Anonymous], 1998, FUNDEMENTALS STAT SI
[6]  
Barrett H. H., 2003, Foundations of Image Science
[7]  
Barrett H.H., 1981, RADIOLOGICAL IMAGING
[8]  
Berger M., Stopping-power and range tables for electrons, protons, and helium ions
[9]   Detective quantum efficiency dependence on x-ray energy weighting in mammography [J].
Cahn, RN ;
Cederström, B ;
Danielsson, M ;
Hall, A ;
Lundqvist, M ;
Nygren, D .
MEDICAL PHYSICS, 1999, 26 (12) :2680-2683
[10]  
Dyson N.A., 1990, X-Rays in Atomic and Nuclear Physics