Position tracking of moving liver lesion based on real-time registration between 2D ultrasound and 3D preoperative images

被引:14
作者
Weon, Chijun [1 ]
Nam, Woo Hyun [1 ]
Lee, Duhgoon [1 ]
Lee, Jae Young [2 ]
Ra, Jong Beom [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Elect Engn, Taejon 305701, South Korea
[2] Seoul Natl Univ Hosp, Dept Radiol, Seoul 110744, South Korea
关键词
ultrasound; 4D preoperative image; image-guided intervention; real-time registration; lesion tracking; NONRIGID REGISTRATION; CT IMAGES; INTENSITY; MOTION;
D O I
10.1118/1.4903945
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Registration between 2D ultrasound (US) and 3D preoperative magnetic resonance (MR) (or computed tomography, CT) images has been studied recently for US-guided intervention. However, the existing techniques have some limits, either in the registration speed or the performance. The purpose of this work is to develop a real-time and fully automatic registration system between two intermodal images of the liver, and subsequently an indirect lesion positioning/tracking algorithm based on the registration result, for image-guided interventions. Methods: The proposed position tracking system consists of three stages. In the preoperative stage, the authors acquire several 3D preoperative MR (or CT) images at different respiratory phases. Based on the transformations obtained from nonrigid registration of the acquired 3D images, they then generate a 4D preoperative image along the respiratory phase. In the intraoperative preparatory stage, they properly attach a 3D US transducer to the patient's body and fix its pose using a holding mechanism. They then acquire a couple of respiratory-controlled 3D US images. Via the rigid registration of these US images to the 3D preoperative images in the 4D image, the pose information of the fixed-pose 3D US transducer is determined with respect to the preoperative image coordinates. As feature(s) to use for the rigid registration, they may choose either internal liver vessels or the inferior vena cava. Since the latter is especially useful in patients with a diffuse liver disease, the authors newly propose using it. In the intraoperative real-time stage, they acquire 2D US images in real-time from the fixed-pose transducer. For each US image, they select candidates for its corresponding 2D preoperative slice from the 4D preoperative MR (or CT) image, based on the predetermined pose information of the transducer. The correct corresponding image is then found among those candidates via real-time 2D registration based on a gradient-based similarity measure. Finally, if needed, they obtain the position information of the liver lesion using the 3D preoperative image to which the registered 2D preoperative slice belongs. Results: The proposed method was applied to 23 clinical datasets and quantitative evaluations were conducted. With the exception of one clinical dataset that included US images of extremely low quality, 22 datasets of various liver status were successfully applied in the evaluation. Experimental results showed that the registration error between the anatomical features of US and preoperative MR images is less than 3 mm on average. The lesion tracking error was also found to be less than 5 mm at maximum. Conclusions: A new system has been proposed for real-time registration between 2D US and successive multiple 3D preoperative MR/CT images of the liver and was applied for indirect lesion tracking for image-guided intervention. The system is fully automatic and robust even with images that had low quality due to patient status. Through visual examinations and quantitative evaluations, it was verified that the proposed system can provide high lesion tracking accuracy as well as high registration accuracy, at performance levels which were acceptable for various clinical applications. (c) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:335 / 347
页数:13
相关论文
共 50 条
  • [31] A hybrid deformable registration method to generate motion-compensated 3D virtual MRI for fusion with interventional real-time 3D ultrasound
    Jhimli Mitra
    Chitresh Bhushan
    Soumya Ghose
    David Mills
    Aqsa Patel
    Heather Chan
    Matthew Tarasek
    Thomas Foo
    Shane Wells
    Sydney Jupitz
    Bryan Bednarz
    Chris Brace
    James Holmes
    Desmond Yeo
    International Journal of Computer Assisted Radiology and Surgery, 2023, 18 (8) : 1501 - 1509
  • [32] Automatic registration between 3D intra-operative ultrasound and pre-operative CT images of the liver based on robust edge matching
    Nam, Woo Hyun
    Kang, Dong-Goo
    Lee, Duhgoon
    Lee, Jae Young
    Ra, Jong Beom
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (01) : 69 - 91
  • [33] 3D Deformable Organ Model Based Liver Motion Tracking in Ultrasound Videos
    Kim, Jung-Bae
    Hwang, Youngkyoo
    Oh, Young-Taek
    Bang, Won-Chul
    Lee, Heesae
    Kim, James D. K.
    Kim, ChangYeong
    MEDICAL IMAGING 2013: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2013, 8671
  • [34] Tracking Endometrial Malacoplakia Through the Evolution of 2D and 3D Ultrasound and Histopathological Features
    Vimercati, Antonella
    Cirignaco, Francesca
    De Nola, Rosalba
    Cerbone, Marco
    Difonzo, Tommaso
    Quarto, Pietro
    Fascilla, Fabiana Divina
    Cicinelli, Ettore
    Resta, Leonardo
    Cazzato, Gerardo
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [35] 3D Physics-Based Registration of 2D Dynamic MRI Data
    Trivisonne, Raffaella
    Peterlik, Igor
    Cotin, Stephane
    Courtecuisse, Hadrien
    MEDICINE MEETS VIRTUAL REALITY 22, 2016, 220 : 432 - 438
  • [36] 2D Ring Array Transducers for Real-Time 3D Imaging of Atrial Septal Defect Repair
    Light, Edward D.
    Lindsey, Brooks D.
    Upchurch, Joseph A.
    Smith, Stephen W.
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 230 - 233
  • [37] HYBRID FEATURE-BASED LOG-DEMONS REGISTRATION FOR TUMOUR TRACKING IN 2-D LIVER ULTRASOUND IMAGES
    Cifor, Amalia
    Risser, Laurent
    Chung, Daniel
    Anderson, Ewan M.
    Schnabel, Julia A.
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 724 - 727
  • [38] 3D shape reconstruction of bone from two x-ray images using 2D/3D non-rigid registration based on moving least-squares deformation
    Cresson, T.
    Branchaud, D.
    Chav, R.
    Godbout, B.
    de Guise, J. A.
    MEDICAL IMAGING 2010: IMAGE PROCESSING, 2010, 7623
  • [39] Joint segmentation and characterization of the dermis in 50 MHz ultrasound 2D and 3D images of the skin
    Sciolla, Bruno
    Le Digabel, Jimmy
    Josse, Gwendal
    Dambry, Thibaut
    Guibert, Benoit
    Delachartre, Philippe
    COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 103 : 277 - 286
  • [40] Convolution neural networks for real-time needle detection and localization in 2D ultrasound
    Mwikirize, Cosmas
    Nosher, John L.
    Hacihaliloglu, Ilker
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2018, 13 (05) : 647 - 657