Position tracking of moving liver lesion based on real-time registration between 2D ultrasound and 3D preoperative images

被引:14
作者
Weon, Chijun [1 ]
Nam, Woo Hyun [1 ]
Lee, Duhgoon [1 ]
Lee, Jae Young [2 ]
Ra, Jong Beom [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Elect Engn, Taejon 305701, South Korea
[2] Seoul Natl Univ Hosp, Dept Radiol, Seoul 110744, South Korea
关键词
ultrasound; 4D preoperative image; image-guided intervention; real-time registration; lesion tracking; NONRIGID REGISTRATION; CT IMAGES; INTENSITY; MOTION;
D O I
10.1118/1.4903945
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Registration between 2D ultrasound (US) and 3D preoperative magnetic resonance (MR) (or computed tomography, CT) images has been studied recently for US-guided intervention. However, the existing techniques have some limits, either in the registration speed or the performance. The purpose of this work is to develop a real-time and fully automatic registration system between two intermodal images of the liver, and subsequently an indirect lesion positioning/tracking algorithm based on the registration result, for image-guided interventions. Methods: The proposed position tracking system consists of three stages. In the preoperative stage, the authors acquire several 3D preoperative MR (or CT) images at different respiratory phases. Based on the transformations obtained from nonrigid registration of the acquired 3D images, they then generate a 4D preoperative image along the respiratory phase. In the intraoperative preparatory stage, they properly attach a 3D US transducer to the patient's body and fix its pose using a holding mechanism. They then acquire a couple of respiratory-controlled 3D US images. Via the rigid registration of these US images to the 3D preoperative images in the 4D image, the pose information of the fixed-pose 3D US transducer is determined with respect to the preoperative image coordinates. As feature(s) to use for the rigid registration, they may choose either internal liver vessels or the inferior vena cava. Since the latter is especially useful in patients with a diffuse liver disease, the authors newly propose using it. In the intraoperative real-time stage, they acquire 2D US images in real-time from the fixed-pose transducer. For each US image, they select candidates for its corresponding 2D preoperative slice from the 4D preoperative MR (or CT) image, based on the predetermined pose information of the transducer. The correct corresponding image is then found among those candidates via real-time 2D registration based on a gradient-based similarity measure. Finally, if needed, they obtain the position information of the liver lesion using the 3D preoperative image to which the registered 2D preoperative slice belongs. Results: The proposed method was applied to 23 clinical datasets and quantitative evaluations were conducted. With the exception of one clinical dataset that included US images of extremely low quality, 22 datasets of various liver status were successfully applied in the evaluation. Experimental results showed that the registration error between the anatomical features of US and preoperative MR images is less than 3 mm on average. The lesion tracking error was also found to be less than 5 mm at maximum. Conclusions: A new system has been proposed for real-time registration between 2D US and successive multiple 3D preoperative MR/CT images of the liver and was applied for indirect lesion tracking for image-guided intervention. The system is fully automatic and robust even with images that had low quality due to patient status. Through visual examinations and quantitative evaluations, it was verified that the proposed system can provide high lesion tracking accuracy as well as high registration accuracy, at performance levels which were acceptable for various clinical applications. (c) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:335 / 347
页数:13
相关论文
共 50 条
  • [21] PWP3D: Real-Time Segmentation and Tracking of 3D Objects
    Prisacariu, Victor A.
    Reid, Ian D.
    INTERNATIONAL JOURNAL OF COMPUTER VISION, 2012, 98 (03) : 335 - 354
  • [22] Real-time 3D ultrasound-based servoing of a surgical instrument
    Stoll, Jeffrey
    Novotny, Paul
    Howe, Robert
    Dupont, Pierre
    2006 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), VOLS 1-10, 2006, : 613 - +
  • [23] Non-rigid registration between 3D ultrasound and CT images of the liver based on intensity and gradient information
    Lee, Duhgoon
    Nam, Woo Hyun
    Lee, Jae Young
    Ra, Jong Beom
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (01) : 117 - 137
  • [24] Extraction of 3D trajectories of mandibular condyles from 2D real-time MRI
    Isaieva, Karyna
    Leclere, Justine
    Paillart, Guillaume
    Drouot, Guillaume
    Felblinger, Jacques
    Dubernard, Xavier
    Vuissoz, Pierre-Andre
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2025, 38 (01): : 131 - 140
  • [25] A MODEL-BASED REGISTRATION APPROACH OF PREOPERATIVE MRI WITH 3D ULTRASOUND OF THE LIVER FOR INTERVENTIONAL GUIDANCE PROCEDURES
    Kadoury, S.
    Zagorchev, L.
    Wood, B. J.
    Venkatesan, A.
    Weese, J.
    Jago, J.
    Kruecker, J.
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 952 - 955
  • [26] A deep learning approach for 2D ultrasound and 3D CT/MR image registration in liver tumor ablation
    Wei Wei
    Xu Haishan
    Alpers, Julian
    Rak, Marko
    Hansen, Christian
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 206
  • [27] Segmentation of ultrasound images - multiresolution 2D and 3D algorithm based on global and local statistics
    Boukerroui, D
    Baskurt, A
    Noble, JA
    Basset, O
    PATTERN RECOGNITION LETTERS, 2003, 24 (4-5) : 779 - 790
  • [28] Developments in real-time 2D ultrasound inspection for aging aircraft
    Lasser, M
    Lasser, B
    Kula, J
    Rohrer, G
    Harrison, G
    NONDESTRUCTIVE EVALUATION OF AGING AIRCRAFT, AIRPORTS, AND AEROSPACE HARDWARE III, 1999, 3586 : 78 - 84
  • [29] Spatial and temporal performance of 3D optical surface imaging for real-time head position tracking
    Wiersma, Rodney D.
    Tomarken, S. L.
    Grelewicz, Zachary
    Belcher, Andrew H.
    Kang, Hyejoo
    MEDICAL PHYSICS, 2013, 40 (11)
  • [30] A hybrid deformable registration method to generate motion-compensated 3D virtual MRI for fusion with interventional real-time 3D ultrasound
    Mitra, Jhimli
    Bhushan, Chitresh
    Ghose, Soumya
    Mills, David
    Patel, Aqsa
    Chan, Heather
    Tarasek, Matthew
    Foo, Thomas
    Wells, Shane
    Jupitz, Sydney
    Bednarz, Bryan
    Brace, Chris
    Holmes, James
    Yeo, Desmond
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2023, 18 (08) : 1501 - 1509