Correlation between Contrast-Enhanced Ultrasound and Microvessel Density via CD31 and CD34 in the rabbit VX2 lung peripheral tumor model

被引:17
|
作者
Xing, Jin [1 ]
He, Wen [1 ]
Ding, Yi-Wen [2 ]
Li, Yang [2 ]
Li, Yan-Dong [3 ]
机构
[1] Capital Med Univ, Beijing Tian Tan Hosp, Dept Ultrasound, 6 Tian Tan Xi Li St, Beijing 100000, Peoples R China
[2] Capital Med Univ, Fuxing Hosp, Dept Ultrasound, Beijing, Peoples R China
[3] Capital Med Univ, Fuxing Hosp, Dept Pathol, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
contrast-enhanced ultrasonography; VX2; tumor; lung cancer; microvessel density; peak intensity; RENAL-CELL CARCINOMA; ENDOTHELIAL GROWTH-FACTOR; COLOR DOPPLER SONOGRAPHY; HEPATOCELLULAR-CARCINOMA; RADIOFREQUENCY ABLATION; BREAST-CANCER; ANGIOGENESIS; ULTRASONOGRAPHY; VASCULARITY; METASTASIS;
D O I
10.11152/mu-1234
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aim: To evaluate the tumor angiogenesis in lung peripheral VX2 tumor model by contrast-enhanced ultrasound (CEUS) and to determine the correlation between CEUS parameters and microvessel density (MVD) calculated via CD31 and CD34 expression. Materials and methods: VX2 pulmonary tumors were created in eight Japanese white rabbits by implanting a VX2 sarcoma into the lower portion of the right lung through ultrasound guidance. Tumors were allowed to grow for 14-21 days to achieve a diameter of 7-15 mm, and were examined by CEUS using a SonoVue contrast agent. The results were recorded as digital video images, and the time-intensity curves and hemodynamic parameters were analyzed. Pathological tumor specimens were immediately obtained after the ultrasound examinations. Tumor specimens were stained with hematoxylin and eosin (H&E) and expressed as CD31 and CD34. The different endothelial cell markers were determined by immunohistochemical staining. MVD was calculated via CD 31 and CD34, and the relationship between CEUS parameters and MVDs was analyzed. Results: Two distinct types of microvessels were identified in lung peripheral VX2 tumors: differentiated (CD34+) and undifferentiated (CD31+) vessels. A significant correlation was found between CEUS parameters and undifferentiated MVD (CD31+ vessels) in lung peripheral VX2 tumors (p<0.05). A reverse correlation was observed between different MVDs. Conclusions: Two different degrees of differentiation of vascular endothelial cells (CD31 and CD34) exist in the rabbit lung peripheral VX2 tumor model. CD31 MVD can more effectively evaluate tumor angiogenesis compared with CD34 MVD. CEUS, as a non-invasive imaging method, can effectively evaluate tumor angiogenesis in rabbit peripheral lung cancer.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 10 条
  • [1] Contrast-enhanced ultrasonography of the rabbit VX2 tumor model: Analysis of vascular pathology
    Liu, Yanjun
    Ren, Weidong
    Liu, Caigang
    Huang, Kun
    Feng, Yueqin
    Wang, Xuemei
    Tong, Yuzhang
    ONCOLOGY LETTERS, 2012, 4 (04) : 685 - 690
  • [2] Novel fluorescence nanobubbles for contrast-enhanced ultrasound imaging in rabbit VX2 hepatocellular carcinoma model
    Yu Houqiang
    Wang Wei
    He Xiaoling
    Zhou Qibing
    Ding Mingyue
    MEDICAL IMAGING 2017: ULTRASONIC IMAGING AND TOMOGRAPHY, 2017, 10139
  • [3] The Correlation of Contrast-Enhanced Ultrasound and MRI Perfusion Quantitative Analysis in Rabbit VX2 Liver Cancer
    Xiang, Zhiming
    Liang, Qianwen
    Liang, Changhong
    Zhong, Guimian
    CELL BIOCHEMISTRY AND BIOPHYSICS, 2014, 70 (03) : 1859 - 1867
  • [4] The Correlation of Contrast-Enhanced Ultrasound and MRI Perfusion Quantitative Analysis in Rabbit VX2 Liver Cancer
    Zhiming Xiang
    Qianwen Liang
    Changhong Liang
    Guimian Zhong
    Cell Biochemistry and Biophysics, 2014, 70 : 1859 - 1867
  • [5] Contrast-Enhanced Ultrasound Differentiation Between Low- and High- Grade Bladder Urothelial Carcinoma and Correlation With Tumor Microvessel Density
    Guo, Suping
    Xu, Pan
    Zhou, Aiyun
    Wang, Gongxian
    Chen, Weimin
    Mei, Jinhong
    Xiao, Fan
    Liu, Juan
    Zhang, Cheng
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (11) : 2287 - 2296
  • [6] Combining dynamic contrast enhanced magnetic resonance imaging and microvessel density to assess the angiogenesis after PEI in a rabbit VX2 liver tumor model
    Chen, Juan
    Qian, Ting
    Zhang, Huanhuan
    Wei, Chunxiao
    Meng, Fanhua
    Yin, Huabin
    MAGNETIC RESONANCE IMAGING, 2016, 34 (02) : 177 - 182
  • [7] Evaluation of neovascularization with spectral computed tomography in a rabbit VX2 liver model: a comparison with real-time contrast-enhanced ultrasound and molecular biological findings
    Zhou, Yue
    Gao, Jian-Bo
    Xu, Han
    Dong, Jun-Qiang
    Wang, Ming-Yue
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1055)
  • [8] Using semi-quantitative dynamic contrast-enhanced magnetic resonance imaging parameters to evaluate tumor hypoxia: a preclinical feasibility study in a maxillofacial VX2 rabbit model
    Zheng, Linfeng
    Li, Yujie
    Geng, Feng
    Zheng, Sujuan
    Yan, Ruiling
    Han, Yuedong
    Wang, Qiben
    Zhang, Zhuoli
    Zhang, Guixiang
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2015, 7 (03): : 535 - 547
  • [9] Stress Test of Contrast-Enhanced US with Phenylephrine in a Rabbit VX2 Liver Tumor Model: Differentiating Benign Periablational Enhancement from Residual Tumor after Radiofrequency Ablation
    Kan, Xuefeng
    Zhang, Yanrong
    Zheng, Chuansheng
    Li, Lin
    Chen, Juan
    Wu, Yihua
    Guo, Tao
    Xiong, Bin
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (07) : 1077 - 1085
  • [10] Relationships between CD34-, CD105-and bcl-2-Expression Levels and Contrast-Enhanced Ultrasound-Based Differential Diagnosis of Adnexal Tumours
    Szymanski, Marek
    Florczyk, Iwona
    Janicki, Radoslaw
    Bernard, Piotr
    Domaracki, Piotr
    Brycht, Lukasz
    Szyca, Robert
    Szymanska, Angelika
    Paniutycz, Julia
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (23)