EXPRESSION OF HEAT SHOCK PROTEIN 70 IN RABBIT LIVER AFTER CONTRAST-ENHANCED ULTRASOUND AND RADIOFREQUENCY ABLATION

被引:38
|
作者
Liu, Guang-Jian [2 ]
Moriyasu, Fuminori [1 ]
Hirokawa, Tomihiko
Rexiati, Munire
Yamada, Masahiko
Imai, Yasuharu
机构
[1] Tokyo Med Univ, Dept Gastroenterol & Hepatol, Shinjuku Ku, Tokyo 1600023, Japan
[2] Sun Yat Sen Univ, Affiliated Hosp 1, Inst Diagnost & Intervent Ultrasound, Dept Med Ultrasound, Guangzhou 510275, Guangdong, Peoples R China
关键词
Contrast agent; Ultrasound; Heat shock protein; Radiofrequency ablation; HEAT-SHOCK PROTEINS; HEPATOCELLULAR-CARCINOMA; THERMAL ABLATION; KUPFFER CELLS; GENE-TRANSFER; AGENT; MICROBUBBLES; BEHAVIOR; HYPERTHERMIA; EFFICIENCY;
D O I
10.1016/j.ultrasmedbio.2009.08.001
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Heat shock proteins (HSPs) induced by thermal ablation therapy may help presenting tumor antigen to the host immune system and be a valuable adjuvant in the ablation therapy of liver cancer. This paper described our preliminary study on the expression of HSP70 in rabbit liver after contrast-enhanced ultrasound (CEUS) and radiofrequency (RF) ablation. Twenty-five male New Zealand white rabbits were divided into five groups as: control group (n=5), ultrasound group (n=5), CEUS group (n=5), RF group (n=5) and CEUS + RF group (n=5). Clinical ultrasound and RF ablation equipment were used in the present experiment. Sonazoid was used as the contrast agent. All the animals were sacrificed 24 h after the procedure, and HSP70 was detected by immunohistochemistry staining and Western blot analysis. In the groups without RF ablation, there was no evidence of HSP70 expression in the liver tissue of the control group and ultrasound group, whereas positive HSP70 expression was detected in the liver tissue of the CEUS group, with a mean optical density of 0.33. In the RF and CEUS + RF groups, there were cells showing HSP70 expression in the normal liver tissue far from the ablation region. The mean densities of HSP70 expression were 0.31 in the RF group and 0.35 in the CEUS + RF group, respectively. With regard to the distribution of HSP70 expression of the RF and CEUS + RF groups, the marginal areas were stronger than liver tissue 1 cm away from the margin, and the ablated tissues showed no evidence of HSP70 expression. The mean density of HSP70 expression in the marginal areas were 0.47 in the RF group and 0.42 in the CEUS + RF group, respectively. CEUS using Sonazoid may produce HSP70 expression in the normal liver parenchyma after CEUS examination and RF ablation. (E-mail: moriyasu@tokyo-med.ac.jp) (C) 2010 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:78 / 85
页数:8
相关论文
共 50 条
  • [21] EFFECT OF MICROBUBBLE-ENHANCED ULTRASOUND ON RADIOFREQUENCY ABLATION OF RABBIT LIVER
    Chen, Zhong
    Zhao, Hongzhi
    Qiao, Xueyan
    Yi, Cuo
    Gao, Shunji
    Gao, Wenhong
    Liu, Zheng
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (07) : 1451 - 1459
  • [22] Hepatocellular nodules in liver cirrhosis: contrast-enhanced ultrasound
    Kim, Tae Kyoung
    Lee, Kyoung Ho
    Khalili, Korosh
    Jang, Hyun-Jung
    ABDOMINAL IMAGING, 2011, 36 (03): : 244 - 263
  • [23] Heat Shock Protein 70 Is Induced in Mouse Human Colon Tumor Xenografts After Sublethal Radiofrequency Ablation
    Weng-Lang Yang
    Deepak G. Nair
    Ryouji Makizumi
    George Gallos
    Xuemei Ye
    Rohit R. Sharma
    T. S. Ravikumar
    Annals of Surgical Oncology, 2004, 11 : 399 - 406
  • [24] Heat shock protein 70 is induced in mouse human colon tumor xenografts after sublethal radiofrequency ablation
    Yang, WL
    Nair, DG
    Makizumi, R
    Gallos, G
    Ye, XM
    Sharma, RR
    Ravikumar, TS
    ANNALS OF SURGICAL ONCOLOGY, 2004, 11 (04) : 399 - 406
  • [25] Elevated serum levels of heat shock protein 70 can be detected after radiofrequency ablation
    Sebastian P. Haen
    Cécile Gouttefangeas
    Diethard Schmidt
    Andreas Boss
    Stephan Clasen
    Alexandra von Herbay
    Bora Kosan
    Hermann Aebert
    Philippe L. Pereira
    Hans-Georg Rammensee
    Cell Stress and Chaperones, 2011, 16 : 495 - 504
  • [26] Intraprocedural contrast-enhanced ultrasound (CEUS) in liver percutaneous radiofrequency ablation: Clinical impact and health technology assessment
    Mauri G.
    Porazzi E.
    Cova L.
    Restelli U.
    Tondolo T.
    Bonfanti M.
    Cerri A.
    Ierace T.
    Croce D.
    Solbiati L.
    Insights into Imaging, 2014, 5 (2) : 209 - 216
  • [27] Clinical application of contrast-enhanced ultrasound after percutaneous renal tumor ablation
    Guo, Fang
    Hu, Bing
    Chen, Lei
    Li, Jia
    BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1103)
  • [28] Contrast-enhanced ultrasound of hepatocarcinogenesis in liver cirrhosis
    Wu Wei
    Chen Min-hua
    Sun, Maryellen
    Yan Kun
    Yang Wei
    Li Ji-you
    CHINESE MEDICAL JOURNAL, 2012, 125 (17) : 3104 - 3109
  • [29] Contrast-Enhanced Ultrasound-Guided Radiofrequency Ablation of Renal Tumors
    O'Neal, Dan
    Cohen, Tal
    Peterson, Cynthia
    Barr, Richard G.
    JOURNAL OF KIDNEY CANCER AND VHL, 2018, 5 (01): : 7 - 14
  • [30] Contrast-enhanced ultrasound improves real-time imaging of ablation region during radiofrequency ablation: Preliminary results
    Wiggermann, P.
    Zuber-Jerger, I.
    Zausig, Y.
    Loss, M.
    Scherer, M. N.
    Schreyer, A. G.
    Stroszczynski, C.
    Jung, E. M.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2011, 49 (1-4) : 43 - 54