Assessment of QT-measurement accuracy using the 12-lead electrocardiogram derived from EASI leads

被引:17
作者
Martinez, Juan Pablo [1 ]
Laguna, Pablo
Olmos, Salvador
Pahlm, Olle
Pettersson, Jonas
Sornmo, Leif
机构
[1] Univ Zaragoza, Ctr Politecn Super, Dept Ingn Elect & Comunicac, Aragon Inst Engn Res, Aragon 50018, Spain
[2] Univ Lund Hosp, Dept Clin Physiol, S-22185 Lund, Sweden
[3] AstraZeneca R&D, Expt Med, Molndal, Sweden
[4] Lund Inst Technol, Dept Electrosci, Lund, Sweden
关键词
D O I
10.1016/j.jelectrocard.2006.08.089
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of the present study is to assess QT-interval measurements from the EASI 12-lead electrocardiogram (ECG) as compared with the standard 12-lead ECG. The QT interval was automatically determined in simultaneously recorded standard and EASI 12-lead ECGs, using a validated wavelet-based delineator. The agreement between the 2 sets of measurements was quantified both on a lead-by-lead basis and a multilead basis with global definitions of QRS onset and T-wave end. The results show that the agreement between QT-interval measurements from the 2 lead systems is acceptable, with negligible mean differences and with correlation coefficients ranging from 0.91 to 0.98 depending on the lead studied. Although the SD shows a clear dependence on the selected lead (ranging from 9.2 to 26.4 milliseconds), differences are within the accepted tolerances for automatic delineation. In a few patients, large differences were found, mainly because of changes in morphology present in both lead systems. QT intervals measured by the multilead approach were considerably more stable than single-lead measurements and resulted in a much better agreement between the 2 lead systems (correlation coefficient, 0.98; QT difference, 1.1 +/- 9.8 milliseconds). Thus, the EASI 12-lead ECG may be used for reliable QT monitoring when the multilead delineation approach is adopted. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:172 / 179
页数:8
相关论文
共 50 条
[31]   Reconstruction of the 12-lead electrocardiogram from reduced lead sets [J].
Nelwan, SP ;
Kors, JA ;
Meij, SH ;
van Bemmel, JH ;
Simoons, ML .
JOURNAL OF ELECTROCARDIOLOGY, 2004, 37 (01) :11-18
[32]   Measurement of skin-electrode impedance for a 12-lead electrocardiogram [J].
Zepeda-Carapia, I ;
Márquez-Espinoza, A ;
Alvarado-Serrano, C .
2005 2nd International Conference on Electrical & Electronics Engineering (ICEEE), 2005, :193-195
[33]   Using the 12-Lead Electrocardiogram in the Care of Athletic Patients [J].
Yeo, Tee Joo ;
Sharma, Sanjay .
CARDIOLOGY CLINICS, 2016, 34 (04) :543-+
[34]   Sensitivity to noise and artifacts of the Mason-Likar 12-lead ECG and the EASI-derived 12-lead ECG for monitoring applications [J].
Thulin, A ;
Pettersson, J ;
Pahlm, O .
CRITICAL CARE MEDICINE, 2002, 30 (12) :A76-A76
[35]   Diagnostic Accuracy of the 12-lead Electrocardiogram in the First 48 Hours of Life in Neonates From a Parent With Genotype Positive Long QT Syndrome [J].
Tobert, Kathryn E. ;
Perez, Yalile ;
Bos, Martijn ;
Ackerman, Michael J. .
CIRCULATION, 2021, 144
[36]   Deriving the 12-lead electrocardiogram from four standard leads based on the Frank Torso model [J].
Wei, D .
PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 :381-384
[37]   TOWARDS WEARABLE AND CONTINUOUS 12-LEAD ELECTROCARDIOGRAM MONITORING Synthesis of the 12-lead Electrocardiogram using 3 Wireless Single-lead Sensors [J].
Figueiredo, C. P. ;
Mendes, P. M. .
BIODEVICES: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, 2012, :329-332
[38]   Modified HEART Score Using the Derived 12-Lead Electrocardiogram and Cardiac Electrical Biomarker [J].
Schreck, D. M. ;
Tansey, W. A. ;
Sheris, S. ;
Gillam, L. ;
Gavi, S. .
ANNALS OF EMERGENCY MEDICINE, 2017, 70 (04) :S18-S18
[39]   XYZ DATA INTERPRETED BY A 12-LEAD COMPUTER-PROGRAM USING THE DERIVED ELECTROCARDIOGRAM [J].
DOWER, GE ;
MACHADO, HB .
JOURNAL OF ELECTROCARDIOLOGY, 1979, 12 (03) :249-261
[40]   Derived electrocardiograms on the posterior leads from the 12-lead system: Method and evaluation [J].
Wei, DM .
PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 :74-77