A novel calibration for L-shell x-ray fluorescence measurements of bone lead concentration using the strontium Kβ/Kα ratio

被引:2
作者
Gherase, Mihai R. [1 ]
Serna, Blaz [1 ]
Kroeker, Sarah [1 ]
机构
[1] Calif State Univ Fresno, Dept Phys, Fresno, CA 93740 USA
基金
美国国家卫生研究院;
关键词
bone; x-ray fluorescence; lead; strontium; calibration; UNITED-STATES; COHERENT NORMALIZATION; NATIONAL-HEALTH; CHILDREN; EXPOSURE; TOXICITY; PHANTOMS; TUBE; PB; AGE;
D O I
10.1088/1361-6579/abf886
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective. Lead (Pb) is a well-known toxic element. In vivo bone Pb concentration measurement is a long-term exposure metric complementary to blood Pb concentration measurement which is a metric of recent exposure. In vivo human tibia bone Pb measurements using Pb K-shell or L-shell x-ray fluorescence (KXRF or LXRF) emissions were developed in the 1980s. KXRF bone Pb measurements using Cd-109 gamma rays and coherent-to-fluorescence ratio to account for differences between phantom and in vivo measurements, was employed in human studies. Bone Pb LXRF method employed x-ray tubes. However, calibration procedures using ultrasound measurements of the soft tissue thickness (STT) proved inaccurate. Approach. In this study, bone and soft tissue (ST) phantoms simulated in vivo bone Pb measurements. Seven plaster-of-Paris cylindrical bone phantoms containing 1.01 mg g(-1) of strontium (Sr) were doped with Pb in 0, 8, 16, 29, 44, 59, and 74 mu g g(-1) concentrations. Polyoxymethylene (POM), resin, and wax were each used to fabricate four ST phantoms in the approximate 1-4 mm thickness range. Pb LXRF measurements were performed using a previously developed optimal grazing incidence position method. Main results. Linear attenuation coefficients measurements of ST materials indicated that POM and resin mimicked well attenuation of Pb x-rays in skin and adipose tissue, respectively. POM and resin data indicated a bone Pb detection limit of 20 mu g g(-1) for a 2 mm STT. Derived relationships between the Pb concentration, Pb LXRF and Sr K- beta /K- alpha ratio data did not require STT knowledge. Applied to POM and resin data, the new calibration method yielded unbiased results. Significance. In vivo bone Pb measurements in children were suggested following considerations of radiation dose, STT, detectability and distribution of Pb and Sr in bone. This research meets with the concerns regarding the negative effects of low levels of Pb exposure on neurodevelopment of children.
引用
收藏
页数:29
相关论文
共 50 条
  • [41] Assessment of the effect of strontium, lead, and aluminum in bone on dual-energy x-ray absorptiometry and quantitative ultrasound measurements: A phantom study
    Jang, Deok Hyun
    Da Silva, Eric
    Tavakkoli, Jahan
    Slatkovska, Lubomira
    Cheung, Angela M.
    Pejovic-Milic, Ana
    MEDICAL PHYSICS, 2018, 45 (01) : 81 - 91
  • [42] K-shell X-ray production cross-sections and fluorescence yields in some medium-Z elements
    Özdemir, Y
    Durak, R
    Öz, E
    RADIATION PHYSICS AND CHEMISTRY, 2002, 65 (03) : 199 - 204
  • [43] Monte Carlo modeling of gold nanoparticles detection limits of benchtop three-dimensional L- and K-shell X-ray fluorescence mapping systems
    Jung, Seongmoon
    X-RAY SPECTROMETRY, 2023, 52 (01) : 28 - 37
  • [44] Energy dispersive X-ray fluorescence determination of cadmium in uranium matrix using Cd Kα line excited by continuum
    Dhara, Sangita
    Misra, N. L.
    Aggarwal, S. K.
    Venugopal, V.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (06) : 461 - 465
  • [45] Non-invasive determination of bone lead in human body using X-ray fluorescence excited by 109Cd
    Huang, SB
    Tian, L
    Cheng, HS
    Pei, P
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24 (11) : 1470 - 1472
  • [46] Effect of annealing temperature on K-shell X-ray fluorescence parameters of zinc oxide thin films prepared by the sol-gel method
    Sirin, Murat
    Baltas, Hasan
    Kiris, Erkan
    Keskenler, Eyup Fahri
    SPECTROSCOPY LETTERS, 2019, 52 (02) : 98 - 104
  • [47] Preliminary determination of calcium,phosphorus,and the calcium/phosphorus ratio in cortical bone of Chinstrap penguin using synchrotron X-ray fluorescence analysis
    谢周清
    程帮波
    孙立广
    黄玉营
    何伟
    赵三平
    Chinese Journal of Polar Science, 2006, (01) : 48 - 54
  • [48] Absolute measurements of anomalous small-angle X-ray scattering intensity using glassy carbon at the Mg K absorption edge
    Aoyama, Keita
    Okuda, Hiroshi
    Lin, Shan
    Mase, Kazuhiko
    Kitajima, Yoshinori
    Tamenori, Yusuke
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2022, 61 (07)
  • [49] Major ion geochemistry in Na-Ca-Mg-K-Cl-SO4 brines using portable X-ray fluorescence spectrometry
    Kipnis, Evan L.
    Bowen, Brenda B.
    Hutchings, Sean J.
    Hynek, Scott A.
    Benison, Kathleen C.
    CHEMICAL GEOLOGY, 2020, 558
  • [50] Development of a Novel X-ray Compatible 3D-Printed Bone Model to Characterize Different K-Wire Fixation Methods in Support of the Treatment of Pediatric Radius Fractures
    Lamberti, Anna Gabriella
    Ujfalusi, Zoltan
    Told, Roland
    Hanna, Daniel
    Jozsa, Gergo
    Maroti, Peter
    POLYMERS, 2021, 13 (23)