A novel calibration for L-shell x-ray fluorescence measurements of bone lead concentration using the strontium Kβ/Kα ratio

被引:2
作者
Gherase, Mihai R. [1 ]
Serna, Blaz [1 ]
Kroeker, Sarah [1 ]
机构
[1] Calif State Univ Fresno, Dept Phys, Fresno, CA 93740 USA
基金
美国国家卫生研究院;
关键词
bone; x-ray fluorescence; lead; strontium; calibration; UNITED-STATES; COHERENT NORMALIZATION; NATIONAL-HEALTH; CHILDREN; EXPOSURE; TOXICITY; PHANTOMS; TUBE; PB; AGE;
D O I
10.1088/1361-6579/abf886
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective. Lead (Pb) is a well-known toxic element. In vivo bone Pb concentration measurement is a long-term exposure metric complementary to blood Pb concentration measurement which is a metric of recent exposure. In vivo human tibia bone Pb measurements using Pb K-shell or L-shell x-ray fluorescence (KXRF or LXRF) emissions were developed in the 1980s. KXRF bone Pb measurements using Cd-109 gamma rays and coherent-to-fluorescence ratio to account for differences between phantom and in vivo measurements, was employed in human studies. Bone Pb LXRF method employed x-ray tubes. However, calibration procedures using ultrasound measurements of the soft tissue thickness (STT) proved inaccurate. Approach. In this study, bone and soft tissue (ST) phantoms simulated in vivo bone Pb measurements. Seven plaster-of-Paris cylindrical bone phantoms containing 1.01 mg g(-1) of strontium (Sr) were doped with Pb in 0, 8, 16, 29, 44, 59, and 74 mu g g(-1) concentrations. Polyoxymethylene (POM), resin, and wax were each used to fabricate four ST phantoms in the approximate 1-4 mm thickness range. Pb LXRF measurements were performed using a previously developed optimal grazing incidence position method. Main results. Linear attenuation coefficients measurements of ST materials indicated that POM and resin mimicked well attenuation of Pb x-rays in skin and adipose tissue, respectively. POM and resin data indicated a bone Pb detection limit of 20 mu g g(-1) for a 2 mm STT. Derived relationships between the Pb concentration, Pb LXRF and Sr K- beta /K- alpha ratio data did not require STT knowledge. Applied to POM and resin data, the new calibration method yielded unbiased results. Significance. In vivo bone Pb measurements in children were suggested following considerations of radiation dose, STT, detectability and distribution of Pb and Sr in bone. This research meets with the concerns regarding the negative effects of low levels of Pb exposure on neurodevelopment of children.
引用
收藏
页数:29
相关论文
共 50 条
  • [31] Mn Lα,β and F Kα resonant X-ray fluorescence spectroscopy of MnF2
    Kawai, J
    Yamamoto, T
    Harada, Y
    Shin, S
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 1067 - 1068
  • [32] Factors influencing uncertainties of in vivo bone lead measurement using a 109Cd K X-ray fluorescence clover leaf geometry detector system
    Behinaein, Sepideh
    Chettle, David R.
    Marro, Leonora
    Malowany, Morie
    Fisher, Mandy
    Fleming, David E. B.
    Healey, Norm
    Inskip, Mike
    Arbuckle, Tye E.
    McNeill, Fiona E.
    ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS, 2014, 16 (12) : 2742 - 2751
  • [33] L-shell x-ray fluorescence relative intensities for elements with 64 ≤ Z ≤ 83 at 21 keV and 25 keV by synchrotron radiation
    Alqadi, M.
    Telfah, M.
    Ibrahim, A.
    Alamat, G.
    Al-Khateeb, H.
    Alzoubi, F.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2025, 338
  • [34] The assessment of a method for measurements and lead quantification in air particulate matter using total reflection X-ray fluorescence spectrometers
    Borgese, Laura
    Bilo, Fabjola
    Zacco, Annalisa
    Federici, Stefania
    Mutahi, Anne Wambui
    Bontempi, Elza
    Trzepla, Krystyna
    Hyslop, Nicole
    Yatkin, Sinan
    Wobrauschek, Peter
    Prost, Joseph
    Ingerle, Dieter
    Depero, Laura E.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 167 (167)
  • [35] 109Cd K x ray fluorescence measurements of tibial lead content in young adults exposed to lead in early childhood
    McNeill, FE
    Stokes, L
    Brito, JAA
    Chettle, DR
    Kaye, WE
    OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2000, 57 (07) : 465 - 471
  • [36] Characterization of matrix effects for Pb L-shell energy dispersive X-ray fluorescence (EDXRF) in binary compounds of cadmium, copper, molybdenum, and zinc
    Narmanli Han, Emine
    Boydas, Elif
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2021, 49 (06) : 616 - 628
  • [37] Monte Carlo modeling of an experimental benchtop L-shell x-ray fluorescence imaging/CT system adopting two silicon drift detectors
    Nepal, Neerajan
    Kaphle, Amrit
    Jayarathna, Sandun
    Cho, Sang Hyun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2025, 1072
  • [38] A new anthropometric phantom for calibrating in vivo measurements of stable lead in the human leg using X-ray fluorescence
    Spitz, H
    Jenkins, M
    Lodwick, J
    Bornschein, R
    HEALTH PHYSICS, 2000, 78 (02): : 159 - 169
  • [39] Measurements of K-shell X-ray production cross-sections and fluorescence yields for some elements in the atomic number range 28 ≤ Z ≤ 40
    Yilmaz, R.
    Tunc, H.
    Ozkartal, A.
    RADIATION PHYSICS AND CHEMISTRY, 2015, 112 : 83 - 87
  • [40] Ex vivo quantification of lanthanum and gadolinium in post-mortem human tibiae with estimated barium and iodine concentrations using K x-ray fluorescence
    Nguyen, Joanna
    Crawfordm, Daniel
    Howarth, David
    Sulchte, Balram
    Pejovic-Milic, Ana
    Grafe, James L.
    PHYSIOLOGICAL MEASUREMENT, 2019, 40 (08)