Tuning a High Transmission Ion Guide to Prevent Gas-Phase Proton Exchange During H/D Exchange MS Analysis

被引:32
作者
Guttman, Miklos [1 ]
Wales, Thomas E. [2 ]
Whittington, Dale [1 ]
Engen, John R. [2 ]
Brown, Jeffery M. [3 ]
Lee, Kelly K. [1 ]
机构
[1] Univ Washington, Dept Med Chem, Seattle, WA 98195 USA
[2] Northeastern Univ, Dept Chem & Chem Biol, Boston, MA 02115 USA
[3] Waters Corp, Stamford Ave, Wilmslow SK9 4AX, Cheshire, England
关键词
Deuterium exchange; HDX; Binomial; Bimodal; Envelope broadening; Gas-phase proton exchange; Deuterium loss; Intermolecular proton exchange; StepWave; Conjoined ion guide; AMIDE HYDROGEN-EXCHANGE; MASS-SPECTROMETRY; SPECTRA; PEPTIDE;
D O I
10.1007/s13361-015-1330-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Hydrogen/deuterium exchange (HDX) mass spectrometry (MS) for protein structural analysis has been adopted for many purposes, including biopharmaceutical development. One of the benefits of examining amide proton exchange by mass spectrometry is that it can readily resolve different exchange regimes, as evidenced by either binomial or bimodal isotope patterns. By careful analysis of the isotope pattern during exchange, more insight can be obtained on protein behavior in solution. However, one must be sure that any observed bimodal isotope patterns are not artifacts of analysis and are reflective of the true behavior in solution. Sample carryover and certain stationary phases are known as potential sources of bimodal artifacts. Here, we describe an additional undocumented source of deuterium loss resulting in artificial bimodal patterns for certain highly charged peptides. We demonstrate that this phenomenon is predominantly due to gas-phase proton exchange between peptides and bulk solvent within the initial stages of high-transmission conjoined ion guides. Minor adjustments of the ion guide settings, as reported here, eliminate the phenomenon without sacrificing signal intensity. Such gas-phase deuterium loss should be appreciated for all HDX-MS studies using such ion optics, even for routine studies not focused on interpreting bimodal spectra.
引用
收藏
页码:662 / 668
页数:7
相关论文
共 26 条
[1]   Hydrogen exchange and mass spectrometry: A historical perspective [J].
Englander, S. Walter .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (11) :1481-1489
[2]   False EX1 signatures caused by sample carryover during HX MS analyses [J].
Fang, Jing ;
Rand, Kasper D. ;
Beuning, Penny J. ;
Engen, John R. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2011, 302 (1-3) :19-25
[3]   Applications of a travelling wave-based radio-frequencyonly stacked ring ion guide [J].
Giles, K ;
Pringle, SD ;
Worthington, KR ;
Little, D ;
Wildgoose, JL ;
Bateman, RH .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (20) :2401-2414
[4]   CD4-Induced Activation in a Soluble HIV-1 Env Trimer [J].
Guttman, Miklos ;
Garcia, Natalie K. ;
Cupo, Albert ;
Matsui, Tsutomu ;
Julien, Jean-Philippe ;
Sanders, Rogier W. ;
Wilson, Ian A. ;
Moore, John P. ;
Lee, Kelly K. .
STRUCTURE, 2014, 22 (07) :974-984
[5]   Analysis of Overlapped and Noisy Hydrogen/Deuterium Exchange Mass Spectra [J].
Guttman, Miklos ;
Weis, David D. ;
Engen, John R. ;
Lee, Kelly K. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2013, 24 (12) :1906-1912
[6]   The Utility of Hydrogen/Deuterium Exchange Mass Spectrometry in Biopharmaceutical Comparability Studies [J].
Houde, Damian ;
Berkowitz, Steven A. ;
Engen, John R. .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2011, 100 (06) :2071-2086
[7]   Hydrogen Exchange Mass Spectrometry: Are We Out of the Quicksand? [J].
Iacob, Roxana E. ;
Engen, John R. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (06) :1003-1010
[8]   Conformation and Dynamics of Biopharmaceuticals: Transition of Mass Spectrometry-Based Tools from Academe to Industry [J].
Kaltashov, Igor A. ;
Bobst, Cedric E. ;
Abzalimov, Rinat R. ;
Berkowitz, Steven A. ;
Houde, Damian .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2010, 21 (03) :323-337
[9]   ExMS: Data Analysis for HX-MS Experiments [J].
Kan, Zhong-Yuan ;
Mayne, Leland ;
Chetty, Palaniappan Sevugan ;
Englander, S. Walter .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2011, 22 (11) :1906-1915
[10]   Minimizing Carry-Over in an Online Pepsin Digestion System used for the H/D Exchange Mass Spectrometric Analysis of an IgG1 Monoclonal Antibody [J].
Majumdar, Ranajoy ;
Manikwar, Prakash ;
Hickey, John M. ;
Arora, Jayant ;
Middaugh, C. Russell ;
Volkin, David B. ;
Weis, David D. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (12) :2140-2148