Raman spectroscopy for real-time and in situ monitoring of mechanochemical milling reactions

被引:73
作者
Lukin, Stipe [1 ]
Uzarevic, Krunoslav [1 ]
Halasz, Ivan [1 ]
机构
[1] Rudjer Boskovic Inst, Zagreb, Croatia
关键词
PROCESS ANALYTICAL TECHNOLOGY; SOLVENT-FREE; MEDICINAL MECHANOCHEMISTRY; COCRYSTAL FORMATION; SCHOLL REACTION; BALL; POLYMORPHISM; MECHANOSYNTHESIS; ACTIVATION; ENERGY;
D O I
10.1038/s41596-021-00545-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This protocol describes how to set up and use Raman spectroscopy for monitoring the course of solid-state reactions in vibratory ball mills, which will help increase our understanding of the mechanisms and kinetics of mechanochemical reactions. Solid-state milling has emerged as an alternative, sustainable approach for preparing virtually all classes of compounds and materials. In situ reaction monitoring is essential to understanding the kinetics and mechanisms of these reactions, but it has proved difficult to use standard analytical techniques to analyze the contents of the closed, rapidly moving reaction chamber (jar). Monitoring by Raman spectroscopy is an attractive choice, because it allows uninterrupted data collection from the outside of a translucent milling jar. It complements the already established in situ monitoring based on powder X-ray diffraction, which has limited accessibility to the wider research community, because it requires a synchrotron X-ray source. The Raman spectroscopy monitoring setup used in this protocol consists of an affordable, small portable spectrometer, a laser source and a Raman probe. Translucent reaction jars, most commonly made from a plastic material, enable interaction of the laser beam with the solid sample residing inside the closed reaction jar and collection of Raman-scattered photons while the ball mill is in operation. Acquired Raman spectra are analyzed using commercial or open-source software for data analysis (e.g., MATLAB, Octave, Python, R). Plotting the Raman spectra versus time enables qualitative analysis of reaction paths. This is demonstrated for an example reaction: the formation in the solid state of a cocrystal between nicotinamide and salicylic acid. A more rigorous data analysis can be achieved using multivariate analysis.
引用
收藏
页码:3492 / +
页数:47
相关论文
共 50 条
[41]   Real-time concentration monitoring using a compact composite sensor array for in situ quality control of aqueous formulations [J].
De la Rosa, Mery Vet George ;
Baez, Jean P. Feng ;
Romanach, Rodolfo J. ;
Lopez-Mejias, Vilmali ;
Stelzer, Torsten .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 206
[42]   Real Time Monitoring of Multiple Parameters in Mammalian Cell Culture Bioreactors Using an In-Line Raman Spectroscopy Probe [J].
Abu-Absi, Nicholas R. ;
Kenty, Brian M. ;
Cuellar, Maryann Ehly ;
Borys, Michael C. ;
Sakhamuri, Sivakesava ;
Strachan, David J. ;
Hausladen, Michael C. ;
Li, Zheng Jian .
BIOTECHNOLOGY AND BIOENGINEERING, 2011, 108 (05) :1215-1221
[43]   The experimental visualisation of molecular structural changes during both photochemical and thermal reactions by real-time vibrational spectroscopy [J].
Iwakura, Izumi .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2011, 13 (13) :5546-5555
[44]   Quantitative in situ monitoring of citric acid phase transition in water using Raman spectroscopy [J].
Caillet, Alexandre ;
Puel, Francois ;
Fevotte, Gilles .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2008, 47 (03) :377-382
[45]   Real-Time Kinetics of Surfactant Molecule Transfer between Emulsion Particles Probed by in Situ Second Harmonic Generation Spectroscopy [J].
You, YuMeng ;
Bloomfield, Aaron ;
Liu, Jian ;
Fu, Li ;
Herzon, Seth B. ;
Yan, Elsa C. Y. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2012, 134 (09) :4264-4268
[46]   Nanoreporter for Real-Time Monitoring of Inflammasome Activity and Targeted Therapy [J].
Nandi, Dipika ;
Forster, James ;
Ramesh, Anujan ;
Nguyen, Anh ;
Bharadwaj, Hariharan ;
Kulkarni, Ashish .
ADVANCED SCIENCE, 2023, 10 (06)
[47]   Embedded Triboelectric Active Sensors for Real-Time Pneumatic Monitoring [J].
Fu, Xian Peng ;
Bu, Tian Zhao ;
Xi, Feng Ben ;
Cheng, Ting Hai ;
Zhang, Chi ;
Wang, Zhong Lin .
ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (37) :32352-32358
[48]   A Dual-FRET-Based Versatile Prodrug for Real-Time Drug Release Monitoring and In Situ Therapeutic Efficacy Evaluation [J].
Li, Shi-Ying ;
Liu, Li-Han ;
Rong, Lei ;
Qiu, Wen-Xiu ;
Jia, Hui-Zhen ;
Li, Bin ;
Li, Fei ;
Zhang, Xian-Zheng .
ADVANCED FUNCTIONAL MATERIALS, 2015, 25 (47) :7317-7326
[49]   In situ real time monitoring of emulsification and homogenization processes for vaccine adjuvants [J].
Ralbovsky, Nicole M. ;
Soukup, Randal J. ;
Lomont, Justin P. ;
Lauro, Mackenzie L. ;
Gulasarian, Amanda ;
Saha-Shah, Anumita ;
Winters, Michael A. ;
Richardson, Douglas D. ;
Wang, Sheng-Ching ;
Mangion, Ian ;
Smith, Joseph P. .
ANALYST, 2022, 147 (03) :378-386
[50]   Real-time helium bubble growth in tungsten by in-situ GISAXS [J].
Corso, L. ;
Curiotto, S. ;
Cheynis, F. ;
Muller, P. ;
Bernard, E. ;
Cabie, M. ;
Martin, C. ;
Leroy, F. .
NUCLEAR MATERIALS AND ENERGY, 2025, 42