Optical Coherence Tomography Angiography Compared With Optical Coherence Tomography Macular Measurements for Detection of Glaucoma

被引:57
作者
Wan, Kelvin H. [1 ,2 ,3 ]
Lam, Alexander K. N. [1 ]
Leung, Christopher Kai-Shun [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, 3-F Hong Kong Eye Hosp,147K Argyle St, Hong Kong, Hong Kong, Peoples R China
[2] Tuen Mun Eye Ctr, Dept Ophthalmol, Hong Kong, Hong Kong, Peoples R China
[3] Tuen Men Hosp, Hong Kong, Hong Kong, Peoples R China
关键词
OPEN-ANGLE GLAUCOMA; VESSEL DENSITY; PERIPAPILLARY ATROPHY; DIAGNOSTIC-ACCURACY; EYES;
D O I
10.1001/jamaophthalmol.2018.1627
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
IMPORTANCE Whether optical coherence tomography angiography (OCT-A) outperforms OCT to detect glaucoma remains inconclusive. OBJECTIVE To compare (1) the diagnostic performance for detection of glaucoma and (2) the structure-function association between inner macular vessel density and inner macular thickness. DESIGN, SETTING, AND PARTICIPANTS This cross-sectional study included 115 patients with glaucoma and 35 healthy individuals for measurements of retinal thickness and retinal vessel density, segmented between the anterior boundary of internal limiting membrane and the posterior boundary of the inner plexiform layer, over the 3 x 3-mm(2) macula using swept-source OCT. All participants were Chinese. Visual sensitivity corresponding to the 3 x 3-mm(2) macular region was expressed in unlogged 1/lambert for investigation of the structure-function associations. Diagnostic performance was evaluated with area under the receiver operating characteristic curves (AUCs). The study was conducted between January 12, 2016, and December 12, 2016. MAIN OUTCOMES AND MEASURES Area under the receiver operating characteristic curve and R-2 analysis. RESULTS Of the 115 patients with glaucoma, 42 (36.5%) were women (mean [SD] age, 53.5 [13.4] years); of the 35 individuals with healthy eyes, 25 (71.4%) were women (age, 60.6 [5.9] years). Inner macular vessel density and thickness were 4.3% (95% CI, 2.4%-6.1%) and 21.1 pm (95% CI, 17.4-24.9 mu m) smaller, respectively, in eyes with glaucoma compared with healthy eyes. The AUC of mean inner macular thickness for glaucoma detection was greater than that of mean inner macular vessel density (difference, 0.17; 95% CI, 0.01-0.31; P = .03). At 90% specificity, the sensitivity of mean inner macular thicknesses for detection of glaucoma was greater than that of mean inner macular vessel densities (difference, 29.2%; 95% CI, 11.5%-64.6%; P = .02). The strength of the structure-function association was stronger for mean inner macular thickness than mean inner macular vessel density in the linear (difference in R-2 = 0.38; 95% CI, 0.22-0.54; P < .001) and nonlinear (difference in R-2 = 0.36; 95% CI, 0.21-0.51; P < .001) regression models. CONCLUSIONS AND RELEVANCE In this study, OCT measurement of inner macular thickness shows a higher diagnostic performance to detect glaucoma and a stronger structure-function association than the currently used OCT-A measurement of inner macular vessel density. These findings may suggest that OCT-A of the macula has a limited role in the diagnostic evaluation of glaucoma.
引用
收藏
页码:866 / 874
页数:9
相关论文
共 50 条
[31]   Promise of Optical Coherence Tomography Angiography in Determining Progression of Glaucoma [J].
Yousefi, Siamak .
JAMA OPHTHALMOLOGY, 2019, 137 (06) :688-689
[32]   Optical Coherence Tomography Angiography in Uveitic Glaucoma - A Pilot Study [J].
Lommatzsch, C. ;
Bauermann, P. ;
Heimes-Bussmann, B. ;
Nolte, C. ;
Heinz, C. .
OCULAR IMMUNOLOGY AND INFLAMMATION, 2021, 29 (7-8) :1410-1416
[33]   Optical coherence tomography and optical coherence tomography angiography imaging in Bietti crystalline dystrophy [J].
Tiryaki Demir, Semra ;
Keles Yesiltas, Sumeyra ;
Kacar, Hakan ;
Akbas, Emine Betul ;
Guven, Dilek .
OPHTHALMIC GENETICS, 2020, 41 (02) :194-197
[34]   The Macular Choriocapillaris Flow in Glaucoma and Within-Day Fluctuations: An Optical Coherence Tomography Angiography Study [J].
Milani, Paolo ;
Urbini, Lara Enrica ;
Bulone, Ennio ;
Nava, Ugo ;
Visintin, Deborah ;
Cremonesi, Giorgia ;
Scotti, Lorenza ;
Bergamini, Fulvio .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (01)
[35]   Peripapillary and Macular Microcirculation in Glaucoma Patients of African and European Descent Using Optical Coherence Tomography Angiography [J].
Taylor, Logan ;
Bojikian, Karine D. ;
Jung, Hoon ;
Chu, Zhongdi ;
Zhou, Xiao ;
Zhang, Qinqin ;
Mudumbai, Raghu C. ;
Waang, Ruikang K. ;
Chen, Philip P. .
JOURNAL OF GLAUCOMA, 2020, 29 (10) :885-889
[36]   Combining Optical Coherence Tomography and Optical Coheremce Tomography Angiography Longitudinal Data for the Detection of Visual Field Progression in Glaucoma [J].
Kamalipour, Alireza ;
Moghimi, Sasan ;
Khosravi, Pooya ;
Mohammadzadeh, Vahid ;
Nishida, Takashi ;
Micheletti, Eleonora ;
Wu, Jo-Hsuan ;
Mahmoudinezhad, Golnoush ;
Li, Elizabeth H. F. ;
Christopher, Mark ;
Zangwill, Linda ;
Javidi, Tara ;
Weinreb, Robert N. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 246 :141-154
[37]   Repeatability of vessel density measurements of optical coherence tomography angiography in normal and glaucoma eyes [J].
Venugopal, Jayasree P. ;
Rao, Harsha L. ;
Weinreb, Robert N. ;
Pradhan, Zia S. ;
Dasari, Srilakshmi ;
Riyazuddin, Mohammed ;
Puttiah, Narenda K. ;
Rao, Dhanraj A. S. ;
Devi, Sathi ;
Mansouri, Kaweh ;
Webers, Carroll A. B. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (03) :352-357
[38]   Optical Coherence Tomography (OCT) in Glaucoma Diagnostics [J].
Hoffmann, E. M. .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2012, 229 (02) :135-142
[39]   Optical Coherence Tomography Errors in Glaucoma [J].
Asrani, Sanjay ;
Edghill, Benjeil ;
Gupta, Yogesh ;
Meerhoff, Guillermo .
JOURNAL OF GLAUCOMA, 2010, 19 (04) :237-242
[40]   Optical Coherence Tomography Angiography in Patients with Amblyopia [J].
Rajavi, Zhale ;
Sabbaghi, Hamideh ;
Hassanpour, Kiana ;
Ahmadieh, Hamid ;
Kheiri, Bahareh ;
Rajabpour, Mojtaba ;
Nourinia, Ramin .
STRABISMUS, 2022, 30 (03) :132-138