Optical Coherence Tomography Angiography Compared With Optical Coherence Tomography Macular Measurements for Detection of Glaucoma

被引:57
|
作者
Wan, Kelvin H. [1 ,2 ,3 ]
Lam, Alexander K. N. [1 ]
Leung, Christopher Kai-Shun [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, 3-F Hong Kong Eye Hosp,147K Argyle St, Hong Kong, Hong Kong, Peoples R China
[2] Tuen Mun Eye Ctr, Dept Ophthalmol, Hong Kong, Hong Kong, Peoples R China
[3] Tuen Men Hosp, Hong Kong, Hong Kong, Peoples R China
关键词
OPEN-ANGLE GLAUCOMA; VESSEL DENSITY; PERIPAPILLARY ATROPHY; DIAGNOSTIC-ACCURACY; EYES;
D O I
10.1001/jamaophthalmol.2018.1627
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
IMPORTANCE Whether optical coherence tomography angiography (OCT-A) outperforms OCT to detect glaucoma remains inconclusive. OBJECTIVE To compare (1) the diagnostic performance for detection of glaucoma and (2) the structure-function association between inner macular vessel density and inner macular thickness. DESIGN, SETTING, AND PARTICIPANTS This cross-sectional study included 115 patients with glaucoma and 35 healthy individuals for measurements of retinal thickness and retinal vessel density, segmented between the anterior boundary of internal limiting membrane and the posterior boundary of the inner plexiform layer, over the 3 x 3-mm(2) macula using swept-source OCT. All participants were Chinese. Visual sensitivity corresponding to the 3 x 3-mm(2) macular region was expressed in unlogged 1/lambert for investigation of the structure-function associations. Diagnostic performance was evaluated with area under the receiver operating characteristic curves (AUCs). The study was conducted between January 12, 2016, and December 12, 2016. MAIN OUTCOMES AND MEASURES Area under the receiver operating characteristic curve and R-2 analysis. RESULTS Of the 115 patients with glaucoma, 42 (36.5%) were women (mean [SD] age, 53.5 [13.4] years); of the 35 individuals with healthy eyes, 25 (71.4%) were women (age, 60.6 [5.9] years). Inner macular vessel density and thickness were 4.3% (95% CI, 2.4%-6.1%) and 21.1 pm (95% CI, 17.4-24.9 mu m) smaller, respectively, in eyes with glaucoma compared with healthy eyes. The AUC of mean inner macular thickness for glaucoma detection was greater than that of mean inner macular vessel density (difference, 0.17; 95% CI, 0.01-0.31; P = .03). At 90% specificity, the sensitivity of mean inner macular thicknesses for detection of glaucoma was greater than that of mean inner macular vessel densities (difference, 29.2%; 95% CI, 11.5%-64.6%; P = .02). The strength of the structure-function association was stronger for mean inner macular thickness than mean inner macular vessel density in the linear (difference in R-2 = 0.38; 95% CI, 0.22-0.54; P < .001) and nonlinear (difference in R-2 = 0.36; 95% CI, 0.21-0.51; P < .001) regression models. CONCLUSIONS AND RELEVANCE In this study, OCT measurement of inner macular thickness shows a higher diagnostic performance to detect glaucoma and a stronger structure-function association than the currently used OCT-A measurement of inner macular vessel density. These findings may suggest that OCT-A of the macula has a limited role in the diagnostic evaluation of glaucoma.
引用
收藏
页码:866 / 874
页数:9
相关论文
共 50 条
  • [1] Optical Coherence Tomography Angiography Compared With Optical Coherence Tomography for Detection of Early Glaucoma With High Myopia
    Chang, Pei-Yao
    Wang, Jiun-Yi
    Wang, Jia-Kang
    Huang, Tzu-Lun
    Hsu, Yung-Ray
    FRONTIERS IN MEDICINE, 2022, 8
  • [2] Optical coherence tomography angiography compared with optical coherence tomography for detection of glaucoma progression with high myopia
    Chang, Pei-Yao
    Wang, Jiun-Yi
    Wang, Jia-Kang
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [3] Macular optical coherence tomography angiography in ischemic optic neuropathy compared to that in glaucoma
    Fard, Masoud Aghsaei
    Ghahvechian, Hossein
    Ritch, Robert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [4] Optical coherence tomography angiography in glaucoma
    Bojikian, Karine D.
    Chen, Philip P.
    Wen, Joanne C.
    CURRENT OPINION IN OPHTHALMOLOGY, 2019, 30 (02) : 110 - 116
  • [5] Optical coherence tomography angiography in glaucoma
    Hong, Jimmy
    Tan, Shayne S.
    Chua, Jacqueline
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2024, 107 (02) : 110 - 121
  • [6] Optical Coherence Tomography Angiography in Glaucoma
    Rao, Harsha L.
    Pradhan, Zia S.
    Suh, Min Hee
    Moghimi, Sasan
    Mansouri, Kaweh
    Weinreb, Robert N.
    JOURNAL OF GLAUCOMA, 2020, 29 (04) : 312 - 321
  • [7] Optical Coherence Tomography Angiography in Glaucoma
    Hollo, Gabor
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2018, 48 (04): : 196 - 201
  • [8] Optical Coherence Tomography Angiography in Glaucoma
    Ma, Jeffrey
    Nesper, Peter L.
    Anchala, Anupama
    Fawzi, Amani A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [9] Optical coherence tomography angiography in glaucoma
    Werner, Jens Ulrich
    Enders, Christian
    Lang, Gerhard K.
    Lang, Gabriele Elisabeth
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [10] Optical coherence tomography angiography in glaucoma
    Fard, Masoud Aghsaei
    Ritch, Robert
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (18)