Determination of physiological levels of volatile organic compounds in blood using static headspace capillary gas chromatography with serial triple detection

被引:10
作者
Schroers, HJ [1 ]
Jermann, E [1 ]
Begerow, J [1 ]
Hajimiragha, H [1 ]
Chiarotti-Omar, AM [1 ]
Dunemann, L [1 ]
机构
[1] Med Inst Umwelthyg, Dept Analyt Chem, D-40225 Dusseldorf, Germany
关键词
biological monitoring; volatile organic compounds; environmental concentrations; gas chromatography; headspace technique; photoionization detection;
D O I
10.1039/a706226e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A static capillary gas chromatographic method using three different detectors [photoionization detector (PID), electron capture detector (ECD) and flame ionization detector (FID)] switched in series is presented for the determination of volatile organic compounds (VOCs) in sub mu g l(-1) levels. The method was applied for the analysis of selected environmentally and occupationally relevant non-halogenated and chlorinated aromatic hydrocarbons (e.g., benzene, toluene, xylenes, dichlorobenzenes) as well as chlorinated aliphatic hydrocarbons (e.g., trichloroethene, tetrachloroethene) in blood samples. Detailed investigations, in respect to the figures of merit were carried out. For most of the selected VOCs detection limits (calculated as the three-fold standard deviation of low level calibration standards) in the range from 26 (benzene) to 67 ng l(-1) (mip-xylene) were achieved which are comparable with those reported for dynamic headspace techniques in combination with mass spectrometric detection. For the individual VOCs the within-series precision varied from 4 to 19% and the day-to-day precision from 11 to 28%, Regarding PID as well as FID the calibration graphs for all substances were linear up to at least 10 mu g l(-1) while the ECD response was linear up to concentrations of about 0.6 mu g l(-1) for the halogenated compounds. Our method is applicable for the quantitative determination of VOCs in blood in the occupationally as well as in the physiologically relevant (normal) concentration range.
引用
收藏
页码:715 / 720
页数:6
相关论文
共 16 条
[1]   THE DETERMINATION OF BENZENE IN HUMAN BLOOD AS AN INDICATOR OF ENVIRONMENTAL EXPOSURE TO VOLATILE AROMATIC-COMPOUNDS [J].
ANGERER, J ;
SCHERER, G ;
SCHALLER, KH ;
MULLER, J .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 339 (10) :740-742
[2]   ENVIRONMENTALLY SIGNIFICANT VOLATILE ORGANIC POLLUTANTS IN HUMAN-BLOOD [J].
ANTOINE, SR ;
DELEON, IR ;
ODELLSMITH, RM .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1986, 36 (03) :364-371
[3]   DETERMINING VOLATILE ORGANIC-COMPOUNDS IN HUMAN BLOOD FROM A LARGE SAMPLE-POPULATION BY USING PURGE AND TRAP GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
ASHLEY, DL ;
BONIN, MA ;
CARDINALI, FL ;
MCCRAW, JM ;
HOLLER, JS ;
NEEDHAM, LL ;
PATTERSON, DG .
ANALYTICAL CHEMISTRY, 1992, 64 (09) :1021-1029
[4]  
Begerow J, 1996, ZBL HYG UMWELTMED, V198, P394
[5]   BREATH AND BLOOD-LEVELS OF BENZENE, TOLUENE, CUMENE AND STYRENE IN NON-OCCUPATIONAL EXPOSURE [J].
BRUGNONE, F ;
PERBELLINI, L ;
FACCINI, GB ;
PASINI, F ;
MARANELLI, G ;
ROMEO, L ;
GOBBI, M ;
ZEDDE, A .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1989, 61 (05) :303-311
[6]   REFERENCE VALUES FOR BLOOD BENZENE IN THE OCCUPATIONALLY UNEXPOSED GENERAL-POPULATION [J].
BRUGNONE, F ;
PERBELLINI, L ;
MARANELLI, G ;
ROMEO, L ;
GUGLIELMI, G ;
LOMBARDINI, F .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1992, 64 (03) :179-184
[7]   DEVELOPMENT OF A SCREENING METHOD FOR THE DETERMINATION OF VOLATILE ORGANIC-COMPOUNDS IN BODY-FLUIDS AND ENVIRONMENTAL-SAMPLES USING PURGE-AND-TRAP GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
DUNEMANN, L ;
HAJIMIRAGHA, H .
ANALYTICA CHIMICA ACTA, 1993, 283 (01) :199-206
[8]  
DUNEMANN L, UNPUB
[9]   Sensitive gas chromatographic method for determination of mercapturic acids in human urine [J].
Einig, T ;
Dunemann, L ;
Dehnen, W .
JOURNAL OF CHROMATOGRAPHY B, 1996, 687 (02) :379-385
[10]  
JERMANN E, 1989, ZBL HYG UMWELTMED, V189, P50