A Novel Thermography-Based Dry Magnetic Particle Testing Method

被引:24
作者
Chen, Yanting [1 ]
Feng, Bo [1 ]
Kang, Yihua [1 ]
Liu, BoCheng [1 ]
Wang, Shenghan [1 ]
Duan, Zhaoqi [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Mech Sci & Engn, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
Crack; ferromagnetic material; heated magnetic particle; infrared thermography; magnetic particle testing (MT); PULSED THERMOGRAPHY; IMPACT DAMAGE; CRACK; SIMULATION; INSPECTION;
D O I
10.1109/TIM.2022.3165742
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Magnetic particle testing (MT) has been widely used in nondestructive testing (NDT) of ferromagnetic materials. MT can be divided into wet method and dry method. The wet method is highly sensitive for microcracks and easy to operate. But the problem is that magnetic suspension liquid utilized in the wet method pollutes both test objects and environment. Dry magnetic particles utilized in dry method are recyclable and environmentally friendly. But the irrelevant magnet particles must be manually removed to reveal the magnetic particle indication (MN). This operation limits both the detection efficiency and sensitivity of dry method. To increase the automation in MT, this article proposes a thermography-based dry MT method (TDMT). Specifically, the dry magnetic particles are heated before utilization and then thermal data are utilized for crack identification. TDMT inherits the economic and environmental advantages of the dry method. Additionally, the time-varying thermal data can provide more useful information than conventional MPI, which makes it possible to identify cracks without manual assistance. The mathematical model of TDMT is designed to prove its feasibility and a dimensionality reduction-based algorithm is applied for crack signal enhancement. Experiments on different specimens with artificial and natural cracks have been conducted. The notch with both a depth of 15 mu m on the standard test shim and a width up to 0.8 mm on the steel plate can be successfully detected. The high sensitivity and wide detection range can be seen from TDMT.
引用
收藏
页数:9
相关论文
共 32 条
[1]  
[Anonymous], 2004, A095901A12004 NF
[2]   Impact Damage Detection and Identification Using Eddy Current Pulsed Thermography Through Integration of PCA and ICA [J].
Cheng, Liang ;
Gao, Bin ;
Tian, Gui Yun ;
Woo, Wai Lok ;
Berthiau, Gerard .
IEEE SENSORS JOURNAL, 2014, 14 (05) :1655-1663
[3]   The Determination of Buried Magnetic Material From Various Heights: A Neural Network Application [J].
Citak, Hakan ;
Ege, Yavuz ;
Bicakci, Sabri ;
Gunes, Huseyin ;
Coramik, Mustafa .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (07) :4188-4199
[4]   Tubing thread inspection by magnetic flux leakage [J].
Ding, JF ;
Kang, YH ;
Wu, XJ .
NDT & E INTERNATIONAL, 2006, 39 (01) :53-56
[5]   Reliability assessment of pulsed thermography and ultrasonic testing for impact damage of CFRP panels [J].
Duan, Yuxia ;
Zhang, Hai ;
Maldague, Xavier P. V. ;
Ibarra-Castanedo, Clemente ;
Servais, Pierre ;
Genest, Marc ;
Sfarra, Stefano ;
Meng, Jianqiao .
NDT & E INTERNATIONAL, 2019, 102 :77-83
[6]   Demonstration of Magnetic Dipole Resonances of Dielectric Nanospheres in the Visible Region [J].
Evlyukhin, Andrey B. ;
Novikov, Sergey M. ;
Zywietz, Urs ;
Eriksen, Rene Lynge ;
Reinhardt, Carsten ;
Bozhevolnyi, Sergey I. ;
Chichkov, Boris N. .
NANO LETTERS, 2012, 12 (07) :3749-3755
[7]  
Feng S., IEEE T INSTRUM MEAS IEEE T INSTRUM MEAS, V70, P2021
[8]   Measurement of magnetic particle for quantitative evaluation in magnetic particle testing [J].
Fukuoka, Katsuhiro ;
Horiike, Sho .
INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2016, 52 (3-4) :1545-1551
[9]   Consideration of multi-coil type magnetizer for detection of omnidirectional crack in magnetic particle testing [J].
Fukuoka, Katsuhiro ;
Noma, Shota ;
Kobayashi, Masaki ;
Ozaki, Tomohiro ;
Oikawa, Yoshiro .
INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2016, 52 (3-4) :1537-1543
[10]   Vision system using linear CCD cameras in fluorescent magnetic particle inspection of axles of railway wheelsets [J].
Hao, HW ;
Li, LM ;
Deng, YH .
Health Monitoring and Smart Nondestructive Evaluation of Structural and Biological Systems IV, 2005, 5768 :442-449